Literature DB >> 24746162

A simplified version of the weight-bearing ankle lunge test: description and test-retest reliability.

Antonio Cejudo1, Pilar Sainz de Baranda2, Francisco Ayala3, Fernando Santonja4.   

Abstract

The purpose of this study was twofold: (1) to describe a new version of the weight-bearing ankle lunge test (WBLT) that is simple to administer, that allows clinicians and sports medicine practitioners to directly assess (in degrees) the ankle dorsiflexion range of motion in a very short period of time while adopting a comfortable testing position; as well as (2) to determine the test-retest reliability of the ankle dorsiflexion range of motion measure obtained from the new version of the WBLT. A total of 50 active adults completed this study. All participants performed the new version of the WBLT on three different occasions, with a two-week interval between testing sessions. Reliability was examined through the change in the mean between consecutive pairs of testing sessions (ChM), standard error of measurement (SEM), minimal detectable change at 95% confidence interval (MDC95), and intraclass correlation coefficient (ICC2,k). The findings showed negligible or trivial ChM values for all the flexibility measures analysed (<1°). Furthermore, the SEM and MDC95 scores for the ankle dorsiflexion measure were 1.3 and 3.8 respectively, and the ICC2k was 0.95. Therefore, this study demonstrated that the ankle dorsiflexion measure obtained from the new version of the WBLT has excellent test-retest reliability scores. Thus, an observed change larger than 3.8° from baseline scores after performing a treatment would indicate that a real change in ankle dorsiflexion range of motion was likely.
Copyright © 2014 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Dorsiflexion; Range of motion; Reproducibility; Sports therapy

Mesh:

Year:  2014        PMID: 24746162     DOI: 10.1016/j.math.2014.03.008

Source DB:  PubMed          Journal:  Man Ther        ISSN: 1356-689X


  8 in total

1.  RELIABILITY OF TWO METHODS OF CLINICAL EXAMINATION OF THE FLEXIBILITY OF THE HIP ADDUCTOR MUSCLES.

Authors:  Antonio Cejudo; Francisco Ayala; Pilar Sainz De Baranda; Fernando Santonja
Journal:  Int J Sports Phys Ther       Date:  2015-12

2.  The validity and reliability of a new instrumented device for measuring ankle dorsiflexion range of motion.

Authors:  Joaquin Calatayud; Fernando Martin; Pedro Gargallo; Jessica García-Redondo; Juan Carlos Colado; Pedro J Marín
Journal:  Int J Sports Phys Ther       Date:  2015-04

3.  Sex Differences in Pre-Season Anthropometric, Balance and Range-of-Motion Characteristics in Elite Youth Soccer Players.

Authors:  Luis Llurda-Almuzara; Albert Pérez-Bellmunt; Noé Labata-Lezaun; Carlos López-de-Celis; Jason Moran; Nicholas C Clark
Journal:  Healthcare (Basel)       Date:  2022-04-28

4.  Inferior tibiofibular joint mobilization with movement and taping does not improve chronic ankle dorsiflexion stiffness: a randomized placebo-controlled trial.

Authors:  Anh Phong Nguyen; Phillipe Mahaudens; Christine Detrembleur; Toby Hall; Benjamin Hidalgo
Journal:  J Man Manip Ther       Date:  2020-08-18

5.  Effects of Mulligan Mobilization with Movement in Subacute Lateral Ankle Sprains: A Pragmatic Randomized Trial.

Authors:  Anh Phong Nguyen; Laurent Pitance; Philippe Mahaudens; Christine Detrembleur; Yuval David; Toby Hall; Benjamin Hidalgo
Journal:  J Man Manip Ther       Date:  2021-02-26

6.  Reliability of the weight-bearing ankle dorsiflexion range of motion measurement using a smartphone goniometer application.

Authors:  Helena Zunko; Renata Vauhnik
Journal:  PeerJ       Date:  2021-09-22       Impact factor: 2.984

7.  Description of ROM-SPORT I Battery: Keys to Assess Lower Limb Flexibility.

Authors:  Antonio Cejudo
Journal:  Int J Environ Res Public Health       Date:  2022-08-29       Impact factor: 4.614

8.  Assessment of the Range of Movement of the Lower Limb in Sport: Advantages of the ROM-SPORT I Battery.

Authors:  Antonio Cejudo; Pilar Sainz de Baranda; Francisco Ayala; Mark De Ste Croix; Fernando Santonja-Medina
Journal:  Int J Environ Res Public Health       Date:  2020-10-19       Impact factor: 3.390

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.