Literature DB >> 25882576

Percutaneous interventions for left atrial appendage exclusion: options, assessment, and imaging using 2D and 3D echocardiography.

Nina C Wunderlich1, Roy Beigel2, Martin J Swaans3, Siew Yen Ho4, Robert J Siegel5.   

Abstract

Percutaneous left atrial appendage (LAA) exclusion is an evolving treatment to prevent embolic events in patients with nonvalvular atrial fibrillation. In the past few years multiple percutaneous devices have been developed to exclude the LAA from the body of the left atrium and thus from the systemic circulation. Two- and 3-dimensional transesophageal echocardiography (TEE) is used to assess the LAA anatomy and its suitability for percutaneous closure to select the type and size of the closure device and to guide the device implantation procedure in conjunction with fluoroscopy. In addition, 2- and 3-dimensional TEE is also used to assess the effectiveness of device implantation acutely and on subsequent follow-up examination. Knowledge of the implantation options that are currently available along with their specific characteristics is essential for choosing the appropriate device for a given patient with a specific LAA anatomy. We present the currently available LAA exclusion devices and the echocardiographic imaging approaches for evaluation of the LAA before, during, and after LAA occlusion.
Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  2D echocardiography; 3D echocardiography; left atrial appendage; percutaneous closure

Mesh:

Year:  2015        PMID: 25882576     DOI: 10.1016/j.jcmg.2015.02.002

Source DB:  PubMed          Journal:  JACC Cardiovasc Imaging        ISSN: 1876-7591


  34 in total

Review 1.  Characterization of the rdar morphotype, a multicellular behaviour in Enterobacteriaceae.

Authors:  U Römling
Journal:  Cell Mol Life Sci       Date:  2005-06       Impact factor: 9.261

2.  The value of the left atrial appendage orifice perimeter of 3D model based on 3D TEE data in the choice of device size of LAmbre™ occluder.

Authors:  Dan Jia; Qing Zhou; Hong-Ning Song; Lan Zhang; Jin-Ling Chen; Yu Liu; Bin Kong; Fa-Zhi He; Yi-Jia Wang; Yuan-Ting Yang
Journal:  Int J Cardiovasc Imaging       Date:  2019-05-27       Impact factor: 2.357

Review 3.  Three-Dimensional Echocardiography: Current Status and Real-Life Applications.

Authors:  Victor Chien-Chia Wu; Masaaki Takeuchi
Journal:  Acta Cardiol Sin       Date:  2017-03       Impact factor: 2.672

4.  [Echocardiography : Important diagnostic pillar in cardiology].

Authors:  R Erbel
Journal:  Herz       Date:  2017-05       Impact factor: 1.443

5.  Patient specific 3D print of left atrial appendage for closure device.

Authors:  Edinrin Obasare; Emmanuel Melendres; D Lynn Morris; Sumeet K Mainigi; Gregg S Pressman
Journal:  Int J Cardiovasc Imaging       Date:  2016-07-06       Impact factor: 2.357

6.  Percutaneous left atrial appendage closure through a patent foramen ovale evaluated by intraprocedural transesophageal echocardiography.

Authors:  Cuizhen Pan; Dehong Kong; Xianhong Shu; Xiaochun Zhang; Daxin Zhou
Journal:  J Echocardiogr       Date:  2016-05-13

Review 7.  [Imaging in structural heart disease : Impact on interventional therapy].

Authors:  A Schmermund; J Eckert; S N Schelle; H Eggebrecht
Journal:  Herz       Date:  2016-11       Impact factor: 1.443

Review 8.  Left Atrial Occlusion Device Implantation: the Role of the Echocardiographer.

Authors:  David Altszuler; Alan F Vainrib; Daniel G Bamira; Ricardo J Benenstein; Anthony Aizer; Larry A Chinitz; Muhamed Saric
Journal:  Curr Cardiol Rep       Date:  2019-06-10       Impact factor: 2.931

Review 9.  Three-dimensional printing in structural heart disease and intervention.

Authors:  Yiting Fan; Randolph H L Wong; Alex Pui-Wai Lee
Journal:  Ann Transl Med       Date:  2019-10

Review 10.  Current Clinical Applications of Three-Dimensional Echocardiography: When the Technique Makes the Difference.

Authors:  Elena Surkova; Denisa Muraru; Patrizia Aruta; Gabriella Romeo; Jurate Bidviene; Diana Cherata; Luigi P Badano
Journal:  Curr Cardiol Rep       Date:  2016-11       Impact factor: 2.931

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.