Abstract

The mechanical properties of vascular tissues affect hemodynamics and can alter disease progression. The uniaxial tensile test is a simple and effective method for determining the stress-strain relationship in arterial tissue ex vivo. To enable calculation of strain, stretch can be measured directly with image tracking of markers on the tissue or indirectly from the distance between the grips used to hold the specimen. While the imaging technique is generally considered more accurate, it also requires more analysis, and the grip distance method is more widely used. The purpose of this study is to compare the stretch of the testing specimen calculated from the grip distance method to that obtained from the imaging method for canine descending aortas and large proximal pulmonary arteries. Our results showed a significant difference in stretch between the two methods; however, this difference was consistently less than 2%. Therefore, the grip distance method is an accurate approximation of the stretch in large elastic arteries in the uniaxial tensile test.
Copyright © 2015 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Grip distance; Imaging technique; Stretch estimation; Uniaxial test

Mesh:

Year:  2015        PMID: 25881308      PMCID: PMC4430367          DOI: 10.1016/j.jmbbm.2015.03.016

Source DB:  PubMed          Journal:  J Mech Behav Biomed Mater        ISSN: 1878-0180


  26 in total

1.  Determination of constitutive equations for human arteries from clinical data.

Authors:  C A J Schulze-Bauer; G A Holzapfel
Journal:  J Biomech       Date:  2003-02       Impact factor: 2.712

2.  Boundary conditions during biaxial testing of planar connective tissues. Part 1: dynamic behavior.

Authors:  Stephen D Waldman; J Michael Lee
Journal:  J Mater Sci Mater Med       Date:  2002-10       Impact factor: 3.896

3.  The effects of grip proximity on perceived local in vitro tendon strain.

Authors:  M L Jimenez; T D Brown; R A Brand
Journal:  J Biomech       Date:  1989       Impact factor: 2.712

4.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

5.  Measurement of mechanical properties of ligament substance from a bone-ligament-bone preparation.

Authors:  S L Woo; M A Gomez; Y Seguchi; C M Endo; W H Akeson
Journal:  J Orthop Res       Date:  1983       Impact factor: 3.494

6.  Characterization of biaxial mechanical behavior of porcine aorta under gradual elastin degradation.

Authors:  Shahrokh Zeinali-Davarani; Ming-Jay Chow; Raphaël Turcotte; Yanhang Zhang
Journal:  Ann Biomed Eng       Date:  2013-01-08       Impact factor: 3.934

7.  Impact of residual stretch and remodeling on collagen engagement in healthy and pulmonary hypertensive calf pulmonary arteries at physiological pressures.

Authors:  Lian Tian; Steven R Lammers; Philip H Kao; Joseph A Albietz; Kurt R Stenmark; H Jerry Qi; Robin Shandas; Kendall S Hunter
Journal:  Ann Biomed Eng       Date:  2012-01-12       Impact factor: 3.934

8.  A microstructurally driven model for pulmonary artery tissue.

Authors:  Philip H Kao; Steven R Lammers; Lian Tian; Kendall Hunter; Kurt R Stenmark; Robin Shandas; H Jerry Qi
Journal:  J Biomech Eng       Date:  2011-05       Impact factor: 2.097

Review 9.  Hyperelastic modelling of arterial layers with distributed collagen fibre orientations.

Authors:  T Christian Gasser; Ray W Ogden; Gerhard A Holzapfel
Journal:  J R Soc Interface       Date:  2006-02-22       Impact factor: 4.118

10.  Pulmonary vascular wall stiffness: An important contributor to the increased right ventricular afterload with pulmonary hypertension.

Authors:  Zhijie Wang; Naomi C Chesler
Journal:  Pulm Circ       Date:  2011 Apr-Jun       Impact factor: 3.017

View more
  4 in total

1.  Pulmonary arterial strain- and remodeling-induced stiffening are differentiated in a chronic model of pulmonary hypertension.

Authors:  Mark J Golob; Diana M Tabima; Gregory D Wolf; James L Johnston; Omid Forouzan; Ashley M Mulchrone; Heidi B Kellihan; Melissa L Bates; Naomi C Chesler
Journal:  J Biomech       Date:  2017-02-21       Impact factor: 2.712

2.  Modeling the effect of collagen fibril alignment on ligament mechanical behavior.

Authors:  Christina J Stender; Evan Rust; Peter T Martin; Erica E Neumann; Raquel J Brown; Trevor J Lujan
Journal:  Biomech Model Mechanobiol       Date:  2017-11-24

3.  Cardiovascular function and structure are preserved despite induced ablation of BMP1-related proteinases.

Authors:  Mark J Golob; Dawiyat Massoudi; Diana M Tabima; James L Johnston; Gregory D Wolf; Timothy A Hacker; Daniel S Greenspan; Naomi C Chesler
Journal:  Cell Mol Bioeng       Date:  2018-06-05       Impact factor: 2.321

4.  Re-examination of the mechanical anisotropy of porcine thoracic aorta by uniaxial tensile tests.

Authors:  Qiang Chen; Yan Wang; Zhi-Yong Li
Journal:  Biomed Eng Online       Date:  2016-12-28       Impact factor: 2.819