Literature DB >> 25865762

A Regulated Trial of Bicuspid Aortic Valve Repair Supported by Geometric Ring Annuloplasty.

Domenico Mazzitelli1, Steffen Pfeiffer2, J Scott Rankin3, Theodor Fischlein2, Yeong-Hoon Choi4, Thorsten Wahlers4, Christian Nöbauer1, Christian Schreiber1, Rüdiger Lange1.   

Abstract

BACKGROUND: Annular stabilization is important during bicuspid aortic valve (BAV) repair to obtain the best long-term results. This report describes the early outcomes of a novel bicuspid annuloplasty ring for this purpose.
METHODS: Under regulatory supervision (NCT02071849), a geometric bicuspid annuloplasty ring was used during valve repair in 16 patients. Three patients had Sievers type 0 valves, 11 had Sievers type 1, and 2 had Sievers type 2. Thirteen patients had left-/right-coronary cusp fusion, 1 had right-/noncoronary cusp fusion, and 2 had both. Moderate to severe aortic insufficiency (AI) was present in 13 of 16 patients, and 3 had mild AI with aortic aneurysms. Ascending aortic aneurysms, root aneurysms, or both were replaced in 7 of 16 patients. The Dacron-covered titanium ring had circular base geometry and two outwardly flaring subcommissural posts positioned opposite on the circumference. The ring was implanted into the annulus beneath the valve, and then leaflet repair was performed.
RESULTS: Immediate postrepair echocardiograms showed grade 0 residual AI in all patients, with good cusp mobility and effective height, and satisfactory gradients. There were no in-hospital or late mortalities. Two patients experienced leaflet tears from long annular suture tails, requiring late valve replacement. After implementation of a lateral suture fixation technique, no more failures occurred. At a mean follow-up time of 9 months, the remaining 14 patients were in New York Heart Association class I, with predominant grade 0 AI.
CONCLUSIONS: As a technique for BAV repair, internal ring annuloplasty produces major annular remodeling and stabilization. Annular reduction and reshaping to a 50/50% symmetric circular geometry facilitates leaflet repair and enhances cusp coaptation. Geometric ring annuloplasty could have useful applications in BAV repair.
Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2015        PMID: 25865762     DOI: 10.1016/j.athoracsur.2015.01.050

Source DB:  PubMed          Journal:  Ann Thorac Surg        ISSN: 0003-4975            Impact factor:   4.330


  9 in total

Review 1.  Annular management during aortic valve repair: a systematic review.

Authors:  Takashi Kunihara
Journal:  Gen Thorac Cardiovasc Surg       Date:  2015-11-25

2.  Aortic valve repair with a newly approved geometric annuloplasty ring in patients undergoing proximal aortic repair: early results from a single-centre experience.

Authors:  Oliver K Jawitz; Vignesh Raman; Jatin Anand; Muath Bishawi; Soraya L Voigt; Julie Doberne; Andrew M Vekstein; E Hope Weissler; Joseph W Turek; G Chad Hughes
Journal:  Eur J Cardiothorac Surg       Date:  2020-06-01       Impact factor: 4.191

3.  Comparison of outcomes following isolated repair of tricuspid versus bicuspid aortic valves.

Authors:  Anatol Prinzing; Johannes Boehm; Magdalena Erlebach; Konstantinos Sideris; Ruediger Lange; Markus Krane
Journal:  J Thorac Dis       Date:  2020-07       Impact factor: 2.895

Review 4.  Bicuspid aortic valve repair: systematic review on long-term outcomes.

Authors:  George J Arnaoutakis; Ibrahim Sultan; Mary Siki; Joseph E Bavaria
Journal:  Ann Cardiothorac Surg       Date:  2019-05

5.  First uses of HAART 300 rings for aortic valve repair in Poland - 4 case studies.

Authors:  Jacek H Juściński; Andrzej Koprowski; Magdalena Kołaczkowska; Maciej M Kowalik; Jan A Rogowski; James S Rankin
Journal:  Kardiochir Torakochirurgia Pol       Date:  2018-03-28

6.  Early results of geometric ring annuloplasty for bicuspid aortic valve repair during aortic aneurysm surgery.

Authors:  Marc W Gerdisch; T Brett Reece; Dominic Emerson; Richard S Downey; Geoffrey B Blossom; Arun Singhal; Joshua N Baker; Theodor J M Fischlein; Vinay Badhwar
Journal:  JTCVS Tech       Date:  2022-06-09

7.  Commentary: Mitral principles for aortic problems.

Authors:  Asvin M Ganapathi; John Bozinovski
Journal:  JTCVS Tech       Date:  2020-01-10

8.  Bicuspid aortic valve repair using geometric ring annuloplasty: A first-in-humans pilot trial.

Authors:  J Scott Rankin; Domenico Mazzitelli; Theodor J M Fischlein; Yeong-Hoon Choi; Diana Aicher; Lawrence M Wei; Vinay Badhwar
Journal:  JTCVS Tech       Date:  2020-01-23

9.  Aortic annuloplasty: Subcommissural, intra-annular suture techniques, external and internal rings.

Authors:  Jan M Federspiel; Tristan Ehrlich; Karen Abeln; Hans-Joachim Schäfers
Journal:  JTCVS Tech       Date:  2021-01-28
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.