Literature DB >> 25863405

Evaluation of 4 Commercial Viewing Devices for Radiographic Perceptibility and Working Length Determination.

Trent Lally1, James R Geist2, Qingzhao Yu3, Van T Himel4, Kent Sabey4.   

Abstract

INTRODUCTION: This study compared images displayed on 1 desktop monitor, 1 laptop monitor, and 2 tablets for the detection of contrast and working length interpretation, with a null hypothesis of no differences between the devices.
METHODS: Three aluminum blocks, with milled circles of varying depth, were radiographed at various exposure levels to create 45 images of varying radiographic density. Six observers viewed the images on 4 devices: Lenovo M92z desktop (Lenovo, Beijing, China), Lenovo Z580 laptop (Lenovo), iPad 3 (Apple, Cupertino, CA), and iPad mini (Apple). Observers recorded the number of circles detected for each image, and a perceptibility curve was used to compare the devices. Additionally, 42 extracted teeth were imaged with working length files affixed at various levels (short, flush, and long) relative to the anatomic apex. Observers measured the distance from file tip to tooth apex on each device. The absolute mean measurement error was calculated for each image. Analysis of variance tests compared the devices. Observers repeated their sessions 1 month later to evaluate intraobserver reliability as measured with weighted kappa tests. Interclass correlation coefficients compared interobserver reliability.
RESULTS: There was no significant difference in perceptibility detection between the Lenovo M92z desktop, iPad 3, and iPad mini. However, on average, all 3 were significantly better than the Lenovo Z580 laptop (P values ≤.015). No significant difference in the mean absolute error was noted for working length measurements among the 4 viewing devices (P = .3509).
CONCLUSIONS: Although all 4 viewing devices seemed comparable with regard to working length evaluation, the laptop computer screen had lower overall ability to perceive contrast differences.
Copyright © 2015 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Contrast; display; perceptibility curve; perception; working length

Mesh:

Year:  2015        PMID: 25863405     DOI: 10.1016/j.joen.2015.02.027

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  3 in total

1.  Impact of room lighting and image display device in the radiographic appearances of the endodontic treatments.

Authors:  Adriana D Cruz; Maria Cn Castro; Marcelo F Aguiar; Ludmilla S Guimarães; Cinthya C Gomes
Journal:  Dentomaxillofac Radiol       Date:  2018-03-12       Impact factor: 2.419

2.  Comparison of digital image displays performance in the detection of artificial internal root resorptions lesions.

Authors:  Matheus Nogueira da Hora; Lucas de Paula Lopes Rosado; Frederico Sampaio Neves; Ieda Crusoé-Rebello; Taruska Ventorini Vasconcelos
Journal:  Dentomaxillofac Radiol       Date:  2021-04-09       Impact factor: 3.525

3.  Influence of embedding media on the accuracy of working length determination by means of apex locator: an ex vivo study.

Authors:  Thomas Gerhard Wolf; Anna Krauß-Mironjuk; Richard Johannes Wierichs; Benjamín Briseño-Marroquín
Journal:  Sci Rep       Date:  2021-02-08       Impact factor: 4.379

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.