Influence of underpreparation on primary stability of implants inserted in poor quality bone sites: an in vitro study.

Marco Degidi1, Giuseppe Daprile1, Adriano Piattelli2.   

Abstract

PURPOSE: The purpose of this present study was to investigate the relation between implant site underpreparation and primary stability in the presence of poor-quality bone.
MATERIALS AND METHODS: A study was performed on fresh humid bovine bone; samples presented no cortical layer with a cancellous structure inside and were obtained from the hip. The bones were firmly attached to a base device. Sixty sites were prepared according to the protocol provided by the manufacturer: a 2-mm pilot drill was introduced to the proper depth and then twist drills of 3 and 3.4 mm were used. After site preparation, 20 3.4- × 11-mm (standard protocol group), 20 3.8- × 11-mm (10% undersized group), and 20 4.5- × 11-mm (25% undersized group) implants were inserted at a calibrated maximum torque of 70 N-cm at the predetermined speed of 30 rpm. After implant insertion, variable torque work (VTW), maximum insertion torque (peak IT), and resonance frequency analysis (RFA) values were recorded.
RESULTS: The standard protocol group showed a mean VTW of 565.77 ± 219.12 N-cm, a peak IT of 11.3 ± 4.44 N-cm, and an RFA of 69.35 ± 7.35 implant stability quotient (ISQ). The 10% undersized group showed a mean VTW of 1,240.24 ± 407.78 N-cm, a peak IT of 20.26 ± 7.03 N-cm, and an RFA of 73.40 ± 2.33 ISQ. The 25% undersized group showed a mean VTW of 1,254.96 ± 727.49 N-cm, a peak IT of 17.15 ± 10.39 N-cm, and an RFA of 72.30 ± 6.70 ISQ. For VTW, the difference between the standard and undersized protocol values was statistically significant; for peak IT, the difference between the standard and 10% undersized protocol values was statistically significant; no other statistical differences were found between mean values.
CONCLUSIONS: In the presence of poor-bone quality, a 10% undersized protocol is sufficient to improve the primary stability of the implant; additional decreases do not seem to enhance primary stability values.
Copyright © 2015 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25861691     DOI: 10.1016/j.joms.2015.01.029

Source DB:  PubMed          Journal:  J Oral Maxillofac Surg        ISSN: 0278-2391            Impact factor:   1.895


  15 in total

Review 1.  Osseodensification -- A systematic review and qualitative analysis of published literature.

Authors:  Ninad Milind Padhye; Ashvini Mukul Padhye; Neel B Bhatavadekar
Journal:  J Oral Biol Craniofac Res       Date:  2019-11-02

2.  Analysis of the relationship between a modified method for implant site preparation and primary implant stability: A pilot study.

Authors:  Gokce Soganci Unsal; Ilser Turkyilmaz
Journal:  J Dent Sci       Date:  2019-12-24       Impact factor: 2.080

Review 3.  Osseodensification - A novel approach in implant dentistry.

Authors:  Umesh Y Pai; Shobha J Rodrigues; Karishma S Talreja; Mahesh Mundathaje
Journal:  J Indian Prosthodont Soc       Date:  2018 Jul-Sep

4.  Correlation between Implant Geometry, Bone Density, and the Insertion Torque/Depth Integral: A Study on Bovine Ribs.

Authors:  Danilo Alessio Di Stefano; Paolo Arosio; Vittoria Perrotti; Giovanna Iezzi; Antonio Scarano; Adriano Piattelli
Journal:  Dent J (Basel)       Date:  2019-03-05

5.  Bone Density and Implant Primary Stability. A Study on Equine Bone Blocks.

Authors:  Francesco Orlando; Federico Arosio; Paolo Arosio; Danilo Alessio Di Stefano
Journal:  Dent J (Basel)       Date:  2019-07-01

6.  New Osseodensification Implant Site Preparation Method to Increase Bone Density in Low-Density Bone: In Vivo Evaluation in Sheep.

Authors:  Paolo Trisi; Marco Berardini; Antonello Falco; Michele Podaliri Vulpiani
Journal:  Implant Dent       Date:  2016-02       Impact factor: 2.454

7.  Correlation between Insertion Torque and Implant Stability Quotient in Tapered Implants with Knife-Edge Thread Design.

Authors:  Domenico Baldi; Teresa Lombardi; Jacopo Colombo; Gabriele Cervino; Giuseppe Perinetti; Roberto Di Lenarda; Claudio Stacchi
Journal:  Biomed Res Int       Date:  2018-05-15       Impact factor: 3.411

8.  The effect of undersizing and tapping on bone to implant contact and implant primary stability: A histomorphometric study on bovine ribs.

Authors:  Danilo Alessio Di Stefano; Vittoria Perrotti; Gian Battista Greco; Claudia Cappucci; Paolo Arosio; Adriano Piattelli; Giovanna Iezzi
Journal:  J Adv Prosthodont       Date:  2018-06-12       Impact factor: 1.904

Review 9.  Clinical Assessment of Dental Implant Stability During Follow-Up: What Is Actually Measured, and Perspectives.

Authors:  Elisabetta M Zanetti; Giulia Pascoletti; Michele Calì; Cristina Bignardi; Giordano Franceschini
Journal:  Biosensors (Basel)       Date:  2018-07-13

10.  Under-Drilling versus Hybrid Osseodensification Technique: Differences in Implant Primary Stability and Bone Density of the Implant Bed Walls.

Authors:  Rafael Delgado-Ruiz; Joshua Gold; Tanya Somohano Marquez; Georgios Romanos
Journal:  Materials (Basel)       Date:  2020-01-15       Impact factor: 3.623

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.