Literature DB >> 25853269

[Aex - the area under the expiratory flow-volume loop].

D Stein1, K Stein2, S Ingrisch1.   

Abstract

Preschool children often show total expiration times of less than one second in pulmonary function tests. Therefore, FEV1 cannot be used for evaluation of obstructive pulmonary diseases in small children. Aex, the area under the expiratory flow-volume loop, does not depend on the expiration time. The Aex value varies according to the convex or concave shape of the flow volume loop, can be quantified and is a valuable parameter in the diagnosis of obstructive airway diseases.In this study FEV1 und Aex values of 19882 flow-volume loops were measured and compared. The comparison shows a very high correlation coefficient of r = 0.99.The changes of both parameters in an individual after provocation or bronchospasmolysis also demonstrate a strong correlation. A 20 % change of FEV1 equals an Aex change of 36 %.We conclude that measuring Aex is a good alternative to measuring FEV1 especially if the FEV1 cannot be obtained due to short expiration times. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Year:  2015        PMID: 25853269     DOI: 10.1055/s-0034-1391401

Source DB:  PubMed          Journal:  Pneumologie        ISSN: 0934-8387


  5 in total

Review 1.  Spirometric indices of early airflow impairment in individuals at risk of developing COPD: Spirometry beyond FEV1/FVC.

Authors:  Daniel Hoesterey; Nilakash Das; Wim Janssens; Russell G Buhr; Fernando J Martinez; Christopher B Cooper; Donald P Tashkin; Igor Barjaktarevic
Journal:  Respir Med       Date:  2019-08-09       Impact factor: 3.415

2.  Assessing small airway disease in GLI versus NHANES III based spirometry using area under the expiratory flow-volume curve.

Authors:  Octavian C Ioachimescu; James K Stoller
Journal:  BMJ Open Respir Res       Date:  2019-11-24

3.  Area under the expiratory flow-volume curve: predicted values by regression and deep learning methods and recommendations for clinical practice.

Authors:  Octavian C Ioachimescu; José A Ramos; Michael Hoffman; James K Stoller
Journal:  BMJ Open Respir Res       Date:  2021-04

4.  Area Under the Expiratory Flow-Volume Curve (AEX): Assessing Bronchodilator Responsiveness.

Authors:  Octavian C Ioachimescu; James K Stoller
Journal:  Lung       Date:  2020-03-24       Impact factor: 2.584

5.  An Alternative Spirometric Measurement. Area under the Expiratory Flow-Volume Curve.

Authors:  Octavian C Ioachimescu; James K Stoller
Journal:  Ann Am Thorac Soc       Date:  2020-05
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.