Literature DB >> 25850154

Multiaxis grip characteristics for varying handle diameters and effort.

Curt B Irwin1, Joseph D Towles1, Robert G Radwin2.   

Abstract

OBJECTIVE: A multiaxis dynamometer was used to quantify grip force vector angles and longitudinal centers of pressure (COPs) while varying handle size and effort used.
BACKGROUND: Authors of many studies have examined maximum grip strength using scalar instruments; a few have measured two-axis forces limited to one or more finger contact. This novel dynamometer uses two instrumented beams that are grasped by the distal fingers and proximal palm to compute two orthogonal components of force and the longitudinal COP through which the force acts.
METHOD: Sixteen healthy, right-handed participants grasped the multiaxis dynamometer with plastic handles ranging in diameter from 3.81 to 7.62 cm. They were required to scale their effort to 25%, 50%, 75%, and 100% of maximum.
RESULTS: Grip force vector angles were affected by both handle diameter and effort level, with angles increasing an average of 8.1° from the least to greatest effort. Longitudinal COP, averaged among the two beams, shifted 1.75 cm radially as handle diameter increased from 3.81 cm to 7.62 cm. Average COP along the beam in contact with the distal finger segments shifted 0.75 cm ulnarly as effort level increased from 25% to 100% of maximum.
CONCLUSION: Grip force characteristics changed with handle diameter and effort level. Overall grip force magnitude comprised both force components measured. APPLICATION: Understanding grip characteristics should be important for handle and grip design and for evaluating hand function.
© 2014, Human Factors and Ergonomics Society.

Entities:  

Keywords:  biomechanics; ergonomic design; grip strength; hand dynamometer; occupational safety and health

Mesh:

Year:  2014        PMID: 25850154      PMCID: PMC5742551          DOI: 10.1177/0018720814544212

Source DB:  PubMed          Journal:  Hum Factors        ISSN: 0018-7208            Impact factor:   2.888


  28 in total

1.  A force transducer to measure individual finger loads during activities of daily living.

Authors:  N K Fowler; A C Nicol
Journal:  J Biomech       Date:  1999-07       Impact factor: 2.712

2.  Effect of grip span on maximal grip force and fatigue of flexor digitorum superficialis.

Authors:  J R Blackwell; K W Kornatz; E M Heath
Journal:  Appl Ergon       Date:  1999-10       Impact factor: 3.661

3.  Initiation and development of fingertip forces during whole-hand grasping.

Authors:  R Reilmann; A M Gordon; H Henningsen
Journal:  Exp Brain Res       Date:  2001-10       Impact factor: 1.972

4.  Reliability and validity of the multiaxis profile dynamometer with younger and older participants.

Authors:  Curt B Irwin; Mary E Sesto
Journal:  J Hand Ther       Date:  2010-04-24       Impact factor: 1.950

5.  A linear force-summing hand dynamometer independent of point of application.

Authors:  R G Radwin; G P Masters; F W Lupton
Journal:  Appl Ergon       Date:  1991-10       Impact factor: 3.661

6.  A new approach to characterize grip force applied to a cylindrical handle.

Authors:  Ren G Dong; John Z Wu; Daniel E Welcome; Thomas W McDowell
Journal:  Med Eng Phys       Date:  2007-03-06       Impact factor: 2.242

7.  The effect of torque direction and cylindrical handle diameter on the coupling between the hand and a cylindrical handle.

Authors:  Na Jin Seo; Thomas J Armstrong; James A Ashton-Miller; Don B Chaffin
Journal:  J Biomech       Date:  2007-06-13       Impact factor: 2.712

8.  Association of muscle strength with functional status of elderly people.

Authors:  R H Hyatt; M N Whitelaw; A Bhat; S Scott; J D Maxwell
Journal:  Age Ageing       Date:  1990-09       Impact factor: 10.668

9.  Effects of aging on hand function.

Authors:  V K Ranganathan; V Siemionow; V Sahgal; G H Yue
Journal:  J Am Geriatr Soc       Date:  2001-11       Impact factor: 5.562

10.  Development and application of a multi-axis dynamometer for measuring grip force.

Authors:  C B Irwin; J D Towles; R G Radwin
Journal:  Ergonomics       Date:  2013-10-17       Impact factor: 2.778

View more