| Literature DB >> 25848318 |
Abeer Abo El Naga1, Mohammed Yousef1, Rasha Ramadan2, Sherif Fayez Bahgat3, Lana Alshawwa4.
Abstract
OBJECTIVE: The aim of the study reported here was to evaluate the performance of a self-adhesive flowable composite and two self-etching adhesive systems, when subjected to cyclic loading, in preventing the nanoleakage of Class V restorations.Entities:
Keywords: Class V; cyclic loading; flowable composite; nanoleakage; self-adhesive
Year: 2015 PMID: 25848318 PMCID: PMC4383219 DOI: 10.2147/CCIDE.S80462
Source DB: PubMed Journal: Clin Cosmet Investig Dent ISSN: 1179-1357
Compositions and manufacturers of the used restorative systems
| Material | Main constituents | Manufacturer | Expiry date | Batch number |
|---|---|---|---|---|
| Xeno® V (self-etching adhesive system) | Bifunctional acrylate, acidic acrylate-functionalized phosphoric ester, acrylic acid, water, tertiary butanol, initiator, and stabilizer | Dentsply Caulk, Milford, DE, USA | March 2015 | 0705001035 |
| BOND-1® SF (solvent-free self-etching adhesive system) | Resin matrix: UDMA, TGDMA, HEMA, 4-META, and photocuring system | Pentron Clinical, Orange, CA, USA | June 2014 | 5627 |
| Fusio™ Liquid Dentin (self-adhesive flowable composite) | Resin matrix: 4-META-based flowable composite | Pentron Clinical | November 2014 | 02541 |
Abbreviations: 4-META, 4-methacryloxyethyl trimellitic acid; HEMA, hydroxyethyl methacrylate; TGDMA, triethylene glycol dimethacrylate; UDMA, urethane dimethacrylate.
Sample groupings
| Adhesive group
| Xeno® V | BOND-1® SF | Fusio™ Liquid Dentin | ||||||
|---|---|---|---|---|---|---|---|---|---|
| Subgroup | 1 | 2 | 3 | 1 | 2 | 3 | 1 | 2 | 3 |
| Loading cycles | Control (no cyclic loading) | 90N for 5,000 cycles | 90N for 10,000 cycles | Control (no cyclic loading) | 90N for 5,000 cycles | 90N for 10,000 cycles | Control (no cyclic loading) | 90N for 5,000 cycles | 90N for 10,000 cycles |
| Number of samples (N=90) | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 | 10 |
Notes:
Manufactured by Dentsply Caulk, Milford, DE, USA;
manufactured by Pentron Clinical, Orange, CA, USA.
Abbreviation: N, newton.
Descriptive statistics for nanoleakage – analysis of variance results
| Adhesive | Cyclic loading | Mean | SD |
|---|---|---|---|
| Xeno® V | Before | 1.88 | 0.47 |
| After 5,000 cycles | 4.49 | 0.57 | |
| After 10,000 cycles | 5.09 | 0.72 | |
| BOND-1® SF | Before | 1.44 | 0.47 |
| After 5,000 cycles | 3.95 | 0.29 | |
| After 10,000 cycles | 4.97 | 0.52 | |
| Fusio™ Liquid Dentin | Before | 0.49 | 0.23 |
| After 5,000 cycles | 0.54 | 0.21 | |
| After 10,000 cycles | 0.61 | 0.23 |
Notes:
Manufactured by Dentsply Caulk, Milford, DE, USA;
manufactured by Pentron Clinical, Orange, CA, USA.
Abbreviation: SD, standard deviation.
Effect of different variables on nanoleakage regression model results
| Source | Type III sum of squares | Mean square | |||
|---|---|---|---|---|---|
| Adhesive system | 32.2 | 2 | 16.1 | 179.2 | <0.001 |
| Cyclic loading | 42.6 | 2 | 21.3 | 131.2 | <0.001 |
| Adhesive system × cyclic loading | 19.6 | 4 | 4.9 | 30.1 | <0.001 |
Note:
Significant at P≤0.05.
Abbreviation: df, degrees of freedom.
Comparison between nanoleakage values with different adhesive systems
| Xeno® V | BOND-1® SF | Fusio™ Liquid Dentin | ||||
|---|---|---|---|---|---|---|
| Mean | SD | Mean | SD | Mean | SD | |
| 3.82c | 1.5 | 3.45c | 1.6 | 0.54d | 0.21 | <0.001 |
Notes:
Manufactured by Dentsply Caulk, Milford, DE, USA;
manufactured by Pentron Clinical, Orange, CA, USA.
Significant at P≤0.05, different letters (ie, c and d) are statistically significantly different.
Abbreviation: SD, standard deviation.
Figure 1Bar chart representing comparison between mean nanoleakage.
Notes: aManufactured by Dentsply Caulk, Milford, DE, USA; bmanufactured by Pentron Clinical, Orange, CA, USA.
Figure 4Scanning electron micrograph (A) and its corresponding electron-dispersive analytical X-ray spectrum curve (B) at one point at the gingival tooth–restoration interface representing Fusio™ Liquid Dentin (self-adhesive flowable composite; Pentron Clinical, Orange, CA, USA) after 5,000 load cycles.
Note: Scale bar in (A) is 100 μm.
Comparison between nanoleakage values before and after cyclic loading
| Before cyclic loading
| After 5,000 load cycles
| After 10,000 load cycles
| ||||
|---|---|---|---|---|---|---|
| Mean | SD | Mean | SD | Mean | SD | |
| 1.27c | 0.71 | 2.99b | 1.85 | 3.56a | 2.21 | <0.001 |
Notes:
Significant at P≤0.05, different letters (a–c) are statistically significantly different.
Abbreviation: SD, standard deviation.
Figure 5Bar chart representing comparison between mean nanoleakage values before and after cyclic loading.
Comparison between nanoleakage with different interactions
| Adhesive system | Cyclic loading | Mean | SD | |
|---|---|---|---|---|
| Xeno® V | Before | 1.88d | 0.47 | <0.001 |
| After 5,000 cycles | 4.49b | 0.57 | ||
| After 10,000 cycles | 5.09a | 0.72 | ||
| BOND-1® SF | Before | 1.44e | 0.47 | |
| After 5,000 cycles | 3.95c | 0.29 | ||
| After 10,000 cycles | 4.97a | 0.52 | ||
| Fusio™ Liquid Dentin | Before | 0.49f | 0.23 | |
| After 5,000 cycles | 0.54f | 0.21 | ||
| After 10,000 cycles | 0.61f | 0.23 |
Notes:
Significant at P≤0.05, different letters (a–f) are statistically significantly different.
Manufactured by Dentsply Caulk, Milford, DE, USA;
manufactured by Pentron Clinical, Orange, CA, USA.
Abbreviation: SD, standard deviation.
Figure 6Bar chart representing comparison between mean nanoleakage values of different interactions.
Notes: aManufactured by Dentsply Caulk, Milford, DE, USA; bmanufactured by Pentron Clinical, Orange, CA, USA.