Literature DB >> 25845704

D-dimers Are a Predictor of Clot Volume Inside Membrane Oxygenators During Extracorporeal Membrane Oxygenation.

Christian Dornia1, Alois Philipp2, Stefan Bauer1, Christian Stroszczynski1, Andreas G Schreyer1, Thomas Müller3, Gudrun E Koehl4, Karla Lehle2.   

Abstract

Thrombosis inside the membrane oxygenator (MO) is a critical complication during venovenous extracorporeal membrane oxygenation (ECMO). The aim of this study was to prove if thrombotic clots manifest within the MO when D-dimer levels are elevated over a long-term period. Heparin-coated polymethylpentene MOs (n = 13) were exchanged due to high plasma D-dimer levels. Clot volume was calculated using multidetector computed tomography (MDCT). Coagulation parameters and MO function were analyzed before and after MO exchange. Before MO exchange, D-dimer levels increased significantly in each patient (11.5 [6.5-15.5] mg/L to 35.0 [34-35] mg/L, P ≤ 0.001). High levels of D-dimers were tolerated for 1 to 6 days. Additionally, fibrinogen concentration (n = 8) and platelet count decreased (n = 8). Within 48 h after exchange, D-dimer levels decreased significantly (n = 11, 12 [8-16] mg/L, P = 0.004). Fibrinogen concentration and platelet counts increased. Clots were found in all MOs in the inlet part of the device. Clot volume (16-106 cm(3) ) did not correlate with MO support time but increased significantly when high D-dimer levels were accepted for >2 days. An increase or high levels of D-dimers in absence of other explaining pathology during ECMO therapy reflected coagulation activity within the MO. Evidence of clots within the MO at high D-dimer levels and decrease after exchange underline the relevance of D-dimer testing during ECMO treatment. Besides, surveillance of MOs during ongoing ECMO therapy will help to predict clot formation, and to avoid system-induced coagulation disorders as well as critical situations.
Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

Entities:  

Keywords:  Clot volume; Coagulation disorder; D-dimers; Extracorporeal membrane oxygenation; Oxygenator thrombosis

Mesh:

Substances:

Year:  2015        PMID: 25845704     DOI: 10.1111/aor.12460

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  14 in total

1.  Emergency Abdominal Surgery Outcomes of Critically Ill Patients on Extracorporeal Membrane Oxygenation: A Case-Matched Study with a Propensity Score Analysis.

Authors:  Anna Taieb; Florence Jeune; Said Lebbah; Matthieu Schmidt; Romain Deransy; Jean-Christophe Vaillant; Charles-Edouard Luyt; Christophe Trésallet; Alain Combes; Nicolas Bréchot
Journal:  World J Surg       Date:  2019-06       Impact factor: 3.352

Review 2.  Oxygenator performance and artificial-native lung interaction.

Authors:  Francesco Epis; Mirko Belliato
Journal:  J Thorac Dis       Date:  2018-03       Impact factor: 2.895

3.  Soluble fibrin is a useful marker for predicting extracorporeal membrane oxygenation circuit exchange because of circuit clots.

Authors:  Kota Hoshino; Kentaro Muranishi; Yasumasa Kawano; Hiroki Hatomoto; Shintaro Yamasaki; Yoshihiko Nakamura; Hiroyasu Ishikura
Journal:  J Artif Organs       Date:  2018-01-30       Impact factor: 1.731

4.  Different mechanisms of oxygenator failure and high plasma von Willebrand factor antigen influence success and survival of venovenous extracorporeal membrane oxygenation.

Authors:  Tamara Steiger; Alois Philipp; Karl-Anton Hiller; Thomas Müller; Matthias Lubnow; Karla Lehle
Journal:  PLoS One       Date:  2021-03-18       Impact factor: 3.240

5.  Life span of different extracorporeal membrane systems for severe respiratory failure in the clinical practice.

Authors:  Alois Philipp; Filip De Somer; Maik Foltan; Andre Bredthauer; Lars Krenkel; Florian Zeman; Karla Lehle
Journal:  PLoS One       Date:  2018-06-01       Impact factor: 3.240

6.  Low flow rate alters haemostatic parameters in an ex-vivo extracorporeal membrane oxygenation circuit.

Authors:  Katrina K Ki; Margaret R Passmore; Chris H H Chan; Maximilian V Malfertheiner; Jonathon P Fanning; Mahé Bouquet; Jonathan E Millar; John F Fraser; Jacky Y Suen
Journal:  Intensive Care Med Exp       Date:  2019-08-20

7.  Technical-Induced Hemolysis in Patients with Respiratory Failure Supported with Veno-Venous ECMO - Prevalence and Risk Factors.

Authors:  Karla Lehle; Alois Philipp; Florian Zeman; Dirk Lunz; Matthias Lubnow; Hans-Peter Wendel; Laszlo Göbölös; Christof Schmid; Thomas Müller
Journal:  PLoS One       Date:  2015-11-25       Impact factor: 3.240

Review 8.  Venovenous Extracorporeal Membrane Oxygenation in Intractable Pulmonary Insufficiency: Practical Issues and Future Directions.

Authors:  T S R Delnoij; R Driessen; A S Sharma; E A Bouman; U Strauch; P M Roekaerts
Journal:  Biomed Res Int       Date:  2016-04-05       Impact factor: 3.411

9.  Order Indication Solicitation to Assess Clinical Laboratory Test Utilization: D-Dimer Order Patterns as an Illustrative Case.

Authors:  Joseph W Rudolf; Jason M Baron; Anand S Dighe
Journal:  J Pathol Inform       Date:  2019-12-03

Review 10.  Toward a Long-Term Artificial Lung.

Authors:  Jutta Arens; Oliver Grottke; Axel Haverich; Lars S Maier; Thomas Schmitz-Rode; Ulrich Steinseifer; H P Wendel; Rolf Rossaint
Journal:  ASAIO J       Date:  2020-08       Impact factor: 3.826

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.