| Literature DB >> 25843155 |
Soo-Young Choi1, Ho-Jung Choi, Ki-Ja Lee, Young-Won Lee.
Abstract
To establish a protocol for a multi-phase computed tomography (CT) of the canine pancreas using the bolus-tracking technique, dynamic scan and multi-phase CT were performed in six normal beagle dogs. The dynamic scan was performed for 60 sec at 1-sec intervals after the injection (4 ml/sec) of a contrast medium, and intervals from aortic enhancement appearance to aortic, pancreatic parenchymal and portal vein peaks were measured. The multi-phase CT with 3 phases was performed three times using a bolus-tracking technique. Scan delays were 0, 15 and 30 in first multi-phase scan; 5, 20 and 35 in second multi-phase scan; and 10, 25 and 40 sec in third multi-phase scan, respectively. Attenuation values and contrast enhancement pattern were analyzed from the aorta, pancreas and portal vein. The intervals from aortic enhancement appearance to aortic, pancreatic parenchymal and portal vein peaks were 3.8 ± 0.7, 8.7 ± 0.9 and 13.3 ± 1.5 sec, respectively. The maximum attenuation values of the aorta, pancreatic parenchyma and portal vein were present at scan sections with no scan delay, a 5-sec delay and a 10-sec delay, respectively. When a multi-phase CT of the canine pancreas is triggered at aortic enhancement appearance using a bolus-tracking technique, the recommended optimal delay times of the arterial and pancreatic parenchymal phases are no scan delay and 5 sec, respectively.Entities:
Mesh:
Substances:
Year: 2015 PMID: 25843155 PMCID: PMC4591144 DOI: 10.1292/jvms.14-0693
Source DB: PubMed Journal: J Vet Med Sci ISSN: 0916-7250 Impact factor: 1.267
Attenuation parameters for the aorta, pancreas and portal vein in normal beagle dogs
| Measurement | Aortic Enhancement Appearance | Aortic Peak | Pancreatic Parenchymal Peak | Portal Vein Peak |
|---|---|---|---|---|
| Arrival Time after Contrast Injection (sec) | 4.7 ± 0.7 | 8.5 ± 0.8 | 13.3 ± 0.7 | 18.0 ± 1.2 |
| Interval from Aortic Enhancement Appearance (sec) | - | 3.8 ± 0.7 | 8.7 ± 0.9 | 13.3 ± 1.5 |
| Pancreatic Attenuation Value (HU) | 50.7 ± 7.6 | 83.7 ± 12.1a) | 133.4 ± 19.9a), b) | 109.8 ± 13.7a), b) |
Data are expressed as mean ± SD. a) The pancreatic attenuation and aortic enhancement appearance values differed significantly with that at aortic enhancement appearance. b) The pancreatic attenuation and aortic peak values differed significantly with that at aortic peak.
Attenuation values for aorta, pancreatic parenchyma and portal vein on nine series of multi-phase CT images with 5 sec intervals
| Scan Delay (sec) | Region of Interest (HU) | ||
|---|---|---|---|
| Aorta | Pancreatic Parenchyma | Portal Vein | |
| 0 | 575.5 ± 219.5 a) | 124.8 ± 14.9 b) | 79.3 ± 40.6 e) |
| 5 | 214.8 ± 47.8 a) | 151.0 ± 14.5 b),c) | 122.3 ± 45.1 e),f) |
| 10 | 148.5 ± 25.0 | 129.5 ± 10.6 c),d) | 215.8 ± 44.8 f) |
| 15 | 203.7 ± 21.7 | 108.2 ± 7.5 d) | 213.2 ± 13.3 |
| 20 | 194.8 ± 28.4 | 111.5 ± 10.0 | 206.2 ± 13.8 |
| 25 | 186.7 ± 13.3 | 109.2 ± 5.0 | 207.2 ± 13.7 |
| 30 | 176.5 ± 8.7 | 101.0 ± 9.7 | 190.3 ± 17.5 |
| 35 | 173.5 ± 13.7 | 101.7 ± 10.0 | 189.7 ± 13.1 |
| 40 | 175.3 ± 19.9 | 99.0 ± 4.5 | 186.2 ± 14.0 |
Data are expressed as mean ± SD. a–f) The values sharing the same superscript letter differ significantly from each other (P<0.05).
Fig. 1.Transverse CT images with no scan delay (A), 5-sec scan delay (B), 10-sec scan delay (C) and 30-sec scan delay (D) at the level of pancreatic body. (A) Arterial phase shows the maximal aortic contrast enhancement (white arrow). (B) Pancreatic parenchymal phase shows the maximal contrast enhancement of pancreas (asterisk). (C) Portal phase has the heterogeneous maximal contrast enhancement of portal vein (black arrow). (D) Delayed phase shows the homogenous venous contrast enhancement (black arrowhead) and hepatic enhancement.