| Literature DB >> 25841674 |
Kathleen Mommaerts1, Ignacio Sanchez2, Fay Betsou2, William Mathieson2.
Abstract
RNA extractions are potentially compromised in terms of both yield and quality by ribonucleases (RNases). The pungent and toxic reducing agent β-mercaptoethanol (β-ME), therefore, is commonly added to the biospecimen's lysis buffer to aid in RNase deactivation. Using different tissue types (liver tissue, kidney tissue, and cell pellets), extraction kits (RNeasy Mini Kit, Illustra RNA Spin Mini Kit, and PureLink Mini Kit), RNA quality assays (RNA integrity numbers [RINs] and quantitative real-time polymerase chain reaction [qRT-PCR]), yield assessments, and in vitro functional RNase assays (RNaseAlert Kit), we demonstrate that β-ME should be replaced by the less toxic dithiothreitol (DTT) alternative.Entities:
Keywords: DTT; Illustra; PureLink; RNase; RNeasy; Ribonuclease
Mesh:
Substances:
Year: 2015 PMID: 25841674 DOI: 10.1016/j.ab.2015.03.027