Literature DB >> 25841310

Application of biodegradable plates for treating pediatric mandibular fractures.

Jingang An1, Pengcheng Jia1, Yi Zhang2, Xi Gong1, Xiaodong Han1, Yang He1.   

Abstract

OBJECTIVE: We assessed the clinical results of a biodegradable plate system for the internal fixation of mandibular fractures in children, and observed the imaging features of fracture healing and bone changes around the biodegradable plates and screws during follow-up. PATIENTS AND METHODS: We enrolled 39 patients (22 male, 17 female, average age 4 years 10 months) with different mandibular fractures. We used 2.0-mm resorbable plates to repair the fractures. Postoperative follow-up ranged from 6 months to 5 years; average follow-up was 1 year 2 months. The outcome measures identified and assessed included facial symmetry, mouth opening, occlusal relationship, infection, nonunion, malunion, and plate dehiscence.
RESULTS: We fixed 42 fractures with 43 resorbable plates; the fracture site of one patient (aged 11 years 3 months) was fixed with two plates. Two patients developed small fistulas at the intraoral incision 2 months after surgery; the fistulas healed after 1 month without special treatment. In the other patients, the incision healed well, there was facial symmetry, mouth opening was >35 mm, and occlusion was good. Follow-up computed tomography examination data were available for 20 cases, and revealed different degrees of radiolucency indicating that osteolysis had occurred. Radiolucency was observed around the resorbable plates 1 month after the surgery. The extent and depth of the radiolucent region were obvious within 1 year of surgery. In the second year, there were obvious repairs, with the bony defect areas becoming shallower. After 2 years, the bony defect areas had almost disappeared.
CONCLUSION: Biodegradable fixation devices are safe and efficient for treating pediatric mandibular fractures. Osteolysis commonly follows biodegradable fixation of pediatric mandibular fractures, and has no adverse effect on fracture healing.
Copyright © 2015 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Biodegradable plate; Children; Internal fixation; Mandibular fracture; Osteolysis; PLGA

Mesh:

Year:  2015        PMID: 25841310     DOI: 10.1016/j.jcms.2015.03.002

Source DB:  PubMed          Journal:  J Craniomaxillofac Surg        ISSN: 1010-5182            Impact factor:   2.078


  7 in total

1.  Comparison of Resorbable Plating Systems: Complications During Degradation.

Authors:  Dennis C Nguyen; Albert S Woo; Scott J Farber; Gary B Skolnick; Jenny Yu; Sybill D Naidoo; Kamlesh B Patel
Journal:  J Craniofac Surg       Date:  2017-01       Impact factor: 1.046

2.  Resorbable Versus Titanium Rigid Fixation for Pediatric Mandibular Fractures: A Systematic Review, Institutional Experience and Comparative Analysis.

Authors:  Matthew E Pontell; Eva B Niklinska; Stephane A Braun; Nolan Jaeger; Kevin J Kelly; Michael S Golinko
Journal:  Craniomaxillofac Trauma Reconstr       Date:  2021-06-21

Review 3.  Making Hardware Removal Unnecessary by Using Resorbable Implants for Osteosynthesis in Children.

Authors:  Pascal Heye; Christoph Matissek; Clemens Seidl; Marcell Varga; Tamas Kassai; Gergö Jozsa; Thomas Krebs
Journal:  Children (Basel)       Date:  2022-03-29

4.  Management of pediatric mandibular fractures using bioresorbable plating system - Efficacy, stability, and clinical outcomes: Our experiences and literature review.

Authors:  Mahinder Singh; R K Singh; Deepak Passi; Mohit Aggarwal; Guneet Kaur
Journal:  J Oral Biol Craniofac Res       Date:  2015-10-17

5.  Lateral wall osteotomy combined with embedded biodegradable implants for displaced intra-articular calcaneal fractures.

Authors:  Yang Yang; Xiaoxiao Zhou; Mengqin Zhang; Yichi Zhou; Bin Wang; Chiting Yuan
Journal:  J Orthop Surg Res       Date:  2019-03-06       Impact factor: 2.359

Review 6.  Titanium or Biodegradable Osteosynthesis in Maxillofacial Surgery? In Vitro and In Vivo Performances.

Authors:  Barzi Gareb; Nico B Van Bakelen; Arjan Vissink; Ruud R M Bos; Baucke Van Minnen
Journal:  Polymers (Basel)       Date:  2022-07-07       Impact factor: 4.967

7.  Mandibular Fracture in Children: A New Approach for Management and Review of Literature.

Authors:  Atul Sharma; Dinesh C Patidar; Geetanjali Gandhi; Kanwaldeep S Soodan; Deepika Patidar
Journal:  Int J Clin Pediatr Dent       Date:  2019 Jul-Aug
  7 in total