Literature DB >> 2583635

[Configuration of corneal incisions with the excimer laser: an experimental study].

G K Lang, J W Koch, E Schröder, M Yanoff, G O Naumann.   

Abstract

The potential applications of an ophthalmic excimer laser at 193 nm include its use as a precise trephine in keratoplasty procedures. In a series of 20 human autopsy and 40 pig cadaver eyes the histological and ultrastructural results of donor and recipient trephination and full-thickness corneal grafting using new mask systems were evaluated. In comparison with other beam delivery systems the "open mask system" allows the performance of excimer laser trephinations with reproducible wound configuration and geometry, with easy handling and high reliability. This technique enables the surgeon to surmount the mechanical limitations of cutting direction and makes non-circular trephinations possible.

Entities:  

Mesh:

Year:  1989        PMID: 2583635

Source DB:  PubMed          Journal:  Fortschr Ophthalmol        ISSN: 0723-8045


  6 in total

1.  "Orientation teeth" in non-mechanical laser corneal trephination for penetrating keratoplasty: 2.94 microm Er:YAG v 193 nm ArF excimer laser.

Authors:  A Behrens; B Seitz; M Küchle; A Langenbucher; M M Kus; C Rummelt; G O Naumann
Journal:  Br J Ophthalmol       Date:  1999-09       Impact factor: 4.638

2.  Corneal shrinkage induced by nonmechanical Q-switched erbium:YAG laser trephination for penetrating keratoplasty in porcine eyes.

Authors:  Milenko Stojkovic; Berthold Seitz; Michael Küchle; Achim Langenbucher; Arne Viestenz; Anja Viestenz; Carmen Hofmann-Rummelt; Gottfried O H Naumann
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2003-07-17       Impact factor: 3.117

3.  Thermal effects in excimer laser trephination of the cornea.

Authors:  A Langenbucher; B Seitz; M M Kus; G O Naumann
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1996-08       Impact factor: 3.117

4.  Excimer laser "corneal shaping": a new technique for customized trephination in penetrating keratoplasty. First experimental results in rabbits.

Authors:  Klaus Schmitz; Wolfram Schreiber; Wolfgang Behrens-Baumann
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2003-04-17       Impact factor: 3.117

5.  [Results of the first 1,000 consecutive elective nonmechanical keratoplasties using the excimer laser. A prospective study over more than 12 years].

Authors:  B Seitz; A Langenbucher; N X Nguyen; M M Kus; M Küchle; G O H Naumann
Journal:  Ophthalmologe       Date:  2004-05       Impact factor: 1.059

6.  Analysis of the changes in keratoplasty indications and preferred techniques.

Authors:  Stefan J Lang; Mona Bischoff; Daniel Böhringer; Berthold Seitz; Thomas Reinhard
Journal:  PLoS One       Date:  2014-11-11       Impact factor: 3.240

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.