Literature DB >> 25835201

Preliminary Assessment of Tricuspid Valve Annular Velocity Parameters by Cardiac Magnetic Resonance Imaging in Adults with a Volume-Overloaded Right Ventricle: Comparison of Unrepaired Atrial Septal Defect and Repaired Tetralogy of Fallot.

Seiji Ito1, Doff B McElhinney, Robert Adams, Puneet Bhatla, Sohae Chung, Leon Axel.   

Abstract

The aim is to compare tricuspid valve (TV) atrioventricular junction (AVJ) annular motion parameters in unrepaired atrial septal defect (ASD) and repaired Tetralogy of Fallot (TOF) by cardiac magnetic resonance (CMR) imaging. We retrospectively reviewed CMR studies performed between November 2007 and November 2013 in patients 16-45 years of age with unrepaired ASD (with or without partial anomalous pulmonary venous return) and with repaired TOF, who had previous infundibulotomy, but have not undergone pulmonary valve replacement. Longitudinal motion of lateral TV in four-chamber view cine image was tracked through the cardiac cycle with custom software. Twenty TOF patients and 12 ASD patients were included, and values were compared with 80 controls. Right ventricular end-diastolic volume index and right ventricular end-systolic volume index were similar in the ASD and TOF groups and were significantly higher in both groups than in controls. Maximum displacement of the TV in systole, velocity at half-maximal displacement during systole, and velocity at half-maximal displacement during early diastole were all significantly lower in the TOF group than the ASD group [1.39 ± 0.47 vs. 2.21 ± 0.46 (cm, p < 0.01), 5.9 ± 2.1 vs. 10.1 ± 2.3 (cm/s, p < 0.01), and 7.7 ± 2.6 vs. 10.9 ± 3.1 (cm/s, p < 0.05)]. TOF patients have diminished early diastolic TV AVJ velocity compared to patients with an unrepaired ASD, despite similar RV volumes. This observation could suggest diastolic dysfunction or cardiac mechanics unique to the postoperative, volume-overloaded right ventricle in patients with repaired TOF.

Entities:  

Mesh:

Year:  2015        PMID: 25835201     DOI: 10.1007/s00246-015-1160-2

Source DB:  PubMed          Journal:  Pediatr Cardiol        ISSN: 0172-0643            Impact factor:   1.655


  18 in total

1.  Tissue-velocity magnetic resonance imaging and tissue Doppler imaging to assess regional myocardial diastolic velocities at the right ventricle in corrected pediatric Tetralogy of Fallot patients.

Authors:  Annelies E van der Hulst; Jos J M Westenberg; Victoria Delgado; Lucia J M Kroft; Eduard R Holman; Nico A Blom; Jeroen J Bax; Albert de Roos; Arno A W Roest
Journal:  Invest Radiol       Date:  2012-03       Impact factor: 6.016

2.  Guidelines for the echocardiographic assessment of the right heart in adults: a report from the American Society of Echocardiography endorsed by the European Association of Echocardiography, a registered branch of the European Society of Cardiology, and the Canadian Society of Echocardiography.

Authors:  Lawrence G Rudski; Wyman W Lai; Jonathan Afilalo; Lanqi Hua; Mark D Handschumacher; Krishnaswamy Chandrasekaran; Scott D Solomon; Eric K Louie; Nelson B Schiller
Journal:  J Am Soc Echocardiogr       Date:  2010-07       Impact factor: 5.251

3.  Ventricular size and function assessed by cardiac MRI predict major adverse clinical outcomes late after tetralogy of Fallot repair.

Authors:  A L Knauth; K Gauvreau; A J Powell; M J Landzberg; E P Walsh; J E Lock; P J del Nido; T Geva
Journal:  Heart       Date:  2006-11-29       Impact factor: 5.994

4.  Value of speckle tracking for the assessment of right ventricular function in patients operated on for tetralogy of fallot. Comparison with magnetic resonance imaging.

Authors:  Yvette Bernard; Mathilde Morel; Vincent Descotes-Genon; Jerome Jehl; Nicolas Meneveau; Francois Schiele
Journal:  Echocardiography       Date:  2013-10-15       Impact factor: 1.724

5.  Regional dysfunction of the right ventricular outflow tract reduces the accuracy of Doppler tissue imaging assessment of global right ventricular systolic function in patients with repaired tetralogy of Fallot.

Authors:  Shelby Kutty; Jing Zhou; Kimberlee Gauvreau; Claudia Trincado; Andrew J Powell; Tal Geva
Journal:  J Am Soc Echocardiogr       Date:  2011-03-09       Impact factor: 5.251

6.  Right ventricular systolic function assessment: rank of echocardiographic methods vs. cardiac magnetic resonance imaging.

Authors:  Michael Pavlicek; Andreas Wahl; Tobias Rutz; Stefano F de Marchi; Ron Hille; Kerstin Wustmann; Hélène Steck; Christina Eigenmann; Markus Schwerzmann; Christian Seiler
Journal:  Eur J Echocardiogr       Date:  2011-09-06

7.  Reliability and accuracy of echocardiographic right heart evaluation in the U.S. Melody Valve Investigational Trial.

Authors:  David W Brown; Doff B McElhinney; Philip A Araoz; Evan M Zahn; Julie A Vincent; John P Cheatham; Thomas K Jones; William E Hellenbrand; Patrick W O'Leary
Journal:  J Am Soc Echocardiogr       Date:  2012-01-21       Impact factor: 5.251

8.  Delayed onset of tricuspid valve flow in repaired tetralogy of Fallot: an additional mechanism of diastolic dysfunction and interventricular dyssynchrony.

Authors:  Ai-Min Sun; Fahad AlHabshan; Michael Cheung; Gabriele Bronzetti; Andrew N Redington; Lee N Benson; Christopher Macgowan; Shi-Joon Yoo
Journal:  J Cardiovasc Magn Reson       Date:  2011-08-24       Impact factor: 5.364

9.  Diastolic function in repaired tetralogy of Fallot at rest and during stress: assessment with MR imaging.

Authors:  Jochem van den Berg; Piotr A Wielopolski; Folkert J Meijboom; Maarten Witsenburg; Ad J J C Bogers; Peter M T Pattynama; Willem A Helbing
Journal:  Radiology       Date:  2007-02-09       Impact factor: 11.105

10.  A novel and practical cardiovascular magnetic resonance method to quantify mitral annular excursion and recoil applied to hypertrophic cardiomyopathy.

Authors:  Shahryar G Saba; Sohae Chung; Sharath Bhagavatula; Robert Donnino; Monvadi B Srichai; Muhamed Saric; Stuart D Katz; Leon Axel
Journal:  J Cardiovasc Magn Reson       Date:  2014-05-20       Impact factor: 5.364

View more
  3 in total

1.  Right Ventricular Function After Pulmonary Artery Banding: Adaptive Processes Assessed by CMR and Conductance Catheter Measurements in Sheep.

Authors:  Hubert Gufler; Sabine Niefeldt; Johannes Boltze; Stephanie Prietz; Christian Klopsch; Sabine Wagner; Brigitte Vollmar; Can Yerebakan
Journal:  J Cardiovasc Transl Res       Date:  2019-03-07       Impact factor: 4.132

2.  Time-resolved tracking of the atrioventricular plane displacement in Cardiovascular Magnetic Resonance (CMR) images.

Authors:  Felicia Seemann; Ulrika Pahlm; Katarina Steding-Ehrenborg; Ellen Ostenfeld; David Erlinge; Jean-Luc Dubois-Rande; Svend Eggert Jensen; Dan Atar; Håkan Arheden; Marcus Carlsson; Einar Heiberg
Journal:  BMC Med Imaging       Date:  2017-02-28       Impact factor: 1.930

3.  Age- and Sex-Specific Changes in CMR Feature Tracking-Based Right Atrial and Ventricular Functional Parameters in Healthy Asians.

Authors:  Shuang Leng; Jiajun Guo; Ru-San Tan; Ping Chai; Lynette Teo; Marielle V Fortier; Chao Gong; Xiaodan Zhao; Ching Ching Ong; John C Allen; Wen Ruan; Angela S Koh; Teng Hong Tan; James W Yip; Ju Le Tan; Yucheng Chen; Liang Zhong
Journal:  Front Cardiovasc Med       Date:  2021-06-04
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.