Literature DB >> 22265459

Reliability and accuracy of echocardiographic right heart evaluation in the U.S. Melody Valve Investigational Trial.

David W Brown1, Doff B McElhinney, Philip A Araoz, Evan M Zahn, Julie A Vincent, John P Cheatham, Thomas K Jones, William E Hellenbrand, Patrick W O'Leary.   

Abstract

BACKGROUND: Appropriate patient selection for transcatheter pulmonary valve (TPV) replacement requires accurate evaluation of right ventricular (RV) performance. The aim of this study was to evaluate the reliability and accuracy of echocardiography for evaluating RV parameters in patients in the five-center Melody TPV trial.
METHODS: Echocardiographic data were compared with cardiac magnetic resonance (CMR) and catheterization; interobserver comparisons were made using site and core laboratory data.
RESULTS: Doppler echocardiographic assessments of RV outflow tract obstruction and RV pressure showed excellent interobserver agreement; mean Doppler gradients were correlated most closely with gradients at catheterization (R = 0.66), and Doppler RV pressure estimates were correlated well with catheterization data (R = 0.58). Assessment of pulmonary regurgitation (PR) using a three-point severity scale showed good agreement with CMR-derived PR fraction (86%). The tricuspid annular Z score was highly reproducible but correlated weakly with CMR RV end-diastolic volume (R = 0.21). However, RV apical diastolic area was highly reproducible (R = 0.87) and had an excellent correlation with CMR RV end-diastolic volume (R = 0.78); all patients with indexed RV apical diastolic areas ≥30 cm(2)/m(2) had CMR RV end-diastolic volumes ≥160 mL/m(2). RV function using the fractional area change method showed a fair correlation with CMR RV ejection fraction (R = 0.48).
CONCLUSIONS: In patients with dysfunctional RV outflow tract conduits, echocardiography provided reproducible, accurate estimates of pressure overload and RV size. Echocardiographic assessment of PR correlated less closely with CMR PR fraction but showed good categorical agreement; assessment of RV function by these methods was suboptimal. Echocardiography alone may be a suitable screening test for some TPV replacement candidates; CMR may be indicated for TPV replacement decisions hinging on assessment of RV function.
Copyright © 2012 American Society of Echocardiography. Published by Mosby, Inc. All rights reserved.

Entities:  

Mesh:

Year:  2012        PMID: 22265459     DOI: 10.1016/j.echo.2011.12.022

Source DB:  PubMed          Journal:  J Am Soc Echocardiogr        ISSN: 0894-7317            Impact factor:   5.251


  3 in total

1.  Preliminary Assessment of Tricuspid Valve Annular Velocity Parameters by Cardiac Magnetic Resonance Imaging in Adults with a Volume-Overloaded Right Ventricle: Comparison of Unrepaired Atrial Septal Defect and Repaired Tetralogy of Fallot.

Authors:  Seiji Ito; Doff B McElhinney; Robert Adams; Puneet Bhatla; Sohae Chung; Leon Axel
Journal:  Pediatr Cardiol       Date:  2015-04-04       Impact factor: 1.655

2.  Left Ventricular Dysfunction Following Neonatal Pulmonary Valve Balloon Dilation for Pulmonary Atresia or Critical Pulmonary Stenosis.

Authors:  Christina Ronai; Rahul H Rathod; Audrey C Marshall; Rebecca Oduor; Kimberlee Gauvreau; Steven D Colan; David W Brown
Journal:  Pediatr Cardiol       Date:  2015-03-13       Impact factor: 1.655

3.  Quantifying pulmonary regurgitation and right ventricular function in surgically repaired tetralogy of Fallot: a comparative analysis of echocardiography and magnetic resonance imaging.

Authors:  Laura Mercer-Rosa; Wei Yang; Shelby Kutty; Jack Rychik; Mark Fogel; Elizabeth Goldmuntz
Journal:  Circ Cardiovasc Imaging       Date:  2012-08-06       Impact factor: 7.792

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.