Literature DB >> 25832294

A rate-based transcutaneous CO2 sensor for noninvasive respiration monitoring.

M Chatterjee1, X Ge, Y Kostov, P Luu, L Tolosa, H Woo, R Viscardi, S Falk, R Potts, G Rao.   

Abstract

The pain and risk of infection associated with invasive blood sampling for blood gas measurements necessitate the search for reliable noninvasive techniques. In this work we developed a novel rate-based noninvasive method for a safe and fast assessment of respiratory status. A small sampler was built to collect the gases diffusing out of the skin. It was connected to a CO2 sensor through gas-impermeable tubing. During a measurement, the CO2 initially present in the sampler was first removed by purging it with nitrogen. The gases in the system were then recirculated between the sampler and the CO2 sensor, and the CO2 diffusion rate into the sampler was measured. Because the measurement is based on the initial transcutaneous diffusion rate, reaching mass transfer equilibrium and heating the skin is no longer required, thus, making it much faster and safer than traditional method. A series of designed experiments were performed to analyze the effect of the measurement parameters such as sampler size, measurement location, subject positions, and movement. After the factor analysis tests, the prototype was sent to a level IV NICU for clinical trial. The results show that the measured initial rate of increase in CO2 partial pressure is linearly correlated with the corresponding arterial blood gas measurements. The new approach can be used as a trending tool, making frequent blood sampling unnecessary for respiratory status monitoring.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25832294      PMCID: PMC4417034          DOI: 10.1088/0967-3334/36/5/883

Source DB:  PubMed          Journal:  Physiol Meas        ISSN: 0967-3334            Impact factor:   2.833


  26 in total

1.  Orthogonal array design in optimizing ERIC-PCR system for fingerprinting rat's intestinal microflora.

Authors:  Y Peng; J Jin; C Wu; J Yang; X Li
Journal:  J Appl Microbiol       Date:  2007-12       Impact factor: 3.772

Review 2.  Volutrauma, PaCO2 levels, and neurodevelopmental sequelae following assisted ventilation.

Authors:  C M Gannon; T E Wiswell; A R Spitzer
Journal:  Clin Perinatol       Date:  1998-03       Impact factor: 3.430

3.  Hypocarbia in the ventilated preterm infant and its effect on intraventricular haemorrhage and bronchopulmonary dysplasia.

Authors:  S J Erickson; A Grauaug; L Gurrin; M Swaminathan
Journal:  J Paediatr Child Health       Date:  2002-12       Impact factor: 1.954

4.  Closed system for blood sampling and transfusion in critically ill patients.

Authors:  Ederlon Rezende; Marcus Antonio Ferez; João Manoel da Silva Junior; Amanda Maria Ribas Rosa de Oliveira; Renata Andréa Pietro Pereira Viana; Ciro Leite Mendes; Diogo de Oliveira Toledo; Miguel Costa Ribeiro Neto; Tatiane Akemi Setoyama
Journal:  Rev Bras Ter Intensiva       Date:  2010-03

5.  An automatic incision device for obtaining blood samples from the heels of preterm infants causes less damage than a conventional manual lancet.

Authors:  H Vertanen; V Fellman; M Brommels; L Viinikka
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2001-01       Impact factor: 5.747

Review 6.  Misleading end-tidal CO2 tensions.

Authors:  R W Wahba; M J Tessler
Journal:  Can J Anaesth       Date:  1996-08       Impact factor: 5.063

7.  Permissive hypercapnia and risk for brain injury and developmental impairment.

Authors:  Erika W Hagen; Mona Sadek-Badawi; David P Carlton; Mari Palta
Journal:  Pediatrics       Date:  2008-09       Impact factor: 7.124

8.  Episodic airway obstruction in premature infants.

Authors:  D A Dransfield; A R Spitzer; W W Fox
Journal:  Am J Dis Child       Date:  1983-05

9.  Hypercapnia during the first 3 days of life is associated with severe intraventricular hemorrhage in very low birth weight infants.

Authors:  J R Kaiser; C H Gauss; M M Pont; D K Williams
Journal:  J Perinatol       Date:  2006-05       Impact factor: 2.521

Review 10.  The design, use, and results of transcutaneous carbon dioxide analysis: current and future directions.

Authors:  Patrick Eberhard
Journal:  Anesth Analg       Date:  2007-12       Impact factor: 5.108

View more
  6 in total

1.  Development and characterization of a point-of care rate-based transcutaneous respiratory status monitor.

Authors:  Xudong Ge; Prosper Adangwa; Ja Young Lim; Yordan Kostov; Leah Tolosa; Richard Pierson; Daniel Herr; Govind Rao
Journal:  Med Eng Phys       Date:  2018-04-05       Impact factor: 2.242

2.  Wearable Transcutaneous CO2 Monitor Based on Miniaturized Nondispersive Infrared Sensor.

Authors:  Vishal Varun Tipparaju; Sabrina Jimena Mora; Jingjing Yu; Francis Tsow; Xiaojun Xian
Journal:  IEEE Sens J       Date:  2021-05-19       Impact factor: 4.325

Review 3.  Carbon Dioxide Sensing-Biomedical Applications to Human Subjects.

Authors:  Emmanuel Dervieux; Michaël Théron; Wilfried Uhring
Journal:  Sensors (Basel)       Date:  2021-12-28       Impact factor: 3.576

4.  What do masks mask? A study on transdermal CO2 monitoring.

Authors:  Kenta Iitani; Joel Tyson; Samyukta Rao; Sai Sathish Ramamurthy; Xudong Ge; Govind Rao
Journal:  Med Eng Phys       Date:  2021-10-27       Impact factor: 2.242

5.  A novel approach to noninvasive monitoring of dissolved carbon dioxide in small-scale cell culture processes.

Authors:  Vida Rahmatnejad; Michael Tolosa; Xudong Ge; Govind Rao
Journal:  Front Bioeng Biotechnol       Date:  2022-09-06

Review 6.  Wearable Health Devices-Vital Sign Monitoring, Systems and Technologies.

Authors:  Duarte Dias; João Paulo Silva Cunha
Journal:  Sensors (Basel)       Date:  2018-07-25       Impact factor: 3.576

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.