Literature DB >> 25821018

Nuclear myocardial perfusion imaging using thallium-201 with a novel multifocal collimator SPECT/CT: IQ-SPECT versus conventional protocols in normal subjects.

Shinro Matsuo1, Kenichi Nakajima, Masahisa Onoguchi, Hiroshi Wakabayash, Koichi Okuda, Seigo Kinuya.   

Abstract

OBJECTIVE: A novel multifocal collimator, IQ-SPECT (Siemens) consists of SMARTZOOM, cardio-centric and 3D iterative SPECT reconstruction and makes it possible to perform MPI scans in a short time. The aims are to delineate the normal uptake in thallium-201 ((201)Tl) SPECT in each acquisition method and to compare the distribution between new and conventional protocol, especially in patients with normal imaging.
METHODS: Forty patients (eight women, mean age of 75 years) who underwent myocardial perfusion imaging were included in the study. All patients underwent one-day protocol perfusion scan after an adenosine-stress test and at rest after administering (201)Tl and showed normal results. Acquisition was performed on a Symbia T6 equipped with a conventional dual-headed gamma camera system (Siemens ECAM) and with a multifocal SMARTZOOM collimator. Imaging was performed with a conventional system followed by IQ-SPECT/computed tomography (CT). Reconstruction was performed with or without X-ray CT-derived attenuation correction (AC). Two nuclear physicians blinded to clinical information interpreted all myocardial perfusion images. A semi-quantitative myocardial perfusion was analyzed by a 17-segment model with a 5-point visual scoring. The uptake of each segment was measured and left ventricular functions were analyzed by QPS software.
RESULTS: IQ-SPECT provided good or excellent image quality. The quality of IQ-SPECT images without AC was similar to those of conventional LEHR study. Mid-inferior defect score (0.3 ± 0.5) in the conventional LEHR study was increased significantly in IQ-SPECT with AC (0 ± 0). IQ-SPECT with AC improved the mid-inferior decreased perfusion shown in conventional images. The apical tracer count in IQ-SPECT with AC was decreased compared to that in LEHR (0.1 ± 0.3 vs. 0.5 ± 0.7, p < 0.05). The left ventricular ejection fraction from IQ-SPECT was significantly higher than that from the LEHR collimator (p = 0.0009).
CONCLUSION: The images of IQ-SPECT acquired in a short time are equivalent to that of conventional LEHR. The results indicated that the IQ-SPECT system with AC is capable of correcting inferior artifacts with high image quality.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25821018     DOI: 10.1007/s12149-015-0965-7

Source DB:  PubMed          Journal:  Ann Nucl Med        ISSN: 0914-7187            Impact factor:   2.668


  11 in total

1.  How to use cardiac IQ•SPECT routinely? An overview of tips and tricks from practical experience to the literature.

Authors:  Eric Gremillet; Denis Agostini
Journal:  Eur J Nucl Med Mol Imaging       Date:  2016-04       Impact factor: 9.236

2.  Creation and characterization of normal myocardial perfusion imaging databases using the IQ·SPECT system.

Authors:  Koichi Okuda; Kenichi Nakajima; Shinro Matsuo; Chisato Kondo; Masayoshi Sarai; Yoriko Horiguchi; Takahiro Konishi; Masahisa Onoguchi; Takeshi Shimizu; Seigo Kinuya
Journal:  J Nucl Cardiol       Date:  2017-01-03       Impact factor: 5.952

3.  New techniques, distinctive population, unique normal databases.

Authors:  James R Galt
Journal:  J Nucl Cardiol       Date:  2017-05-04       Impact factor: 5.952

4.  Prognostic value of normal stress myocardial perfusion imaging and ventricular function in Japanese patients with chronic kidney disease: a study based on the J-ACCESS-3 database.

Authors:  Shinro Matsuo; Kenichi Nakajima; Yasuchika Takeishi; Tsunehiko Nishimura
Journal:  Eur J Nucl Med Mol Imaging       Date:  2018-03-03       Impact factor: 9.236

5.  The Incremental Diagnostic Performance of Coronary Computed Tomography Angiography Added to Myocardial Perfusion Imaging in Patients with Intermediate-to-High Cardiovascular Risk.

Authors:  Pei-Ying Hsu; Wen-Jeng Lee; Mei-Fang Cheng; Ruoh-Fang Yen; Kai-Yuan Tzen; Yen-Wen Wu
Journal:  Acta Cardiol Sin       Date:  2016-03       Impact factor: 2.672

6.  Dose reduction in half-time myocardial perfusion SPECT-CT with multifocal collimation.

Authors:  Morgan C Lyon; Courtney Foster; Xinhong Ding; Sharmila Dorbala; Don Spence; Manojeet Bhattacharya; A Hans Vija; Marcelo F DiCarli; Stephen C Moore
Journal:  J Nucl Cardiol       Date:  2016-03-31       Impact factor: 5.952

Review 7.  Normal values and standardization of parameters in nuclear cardiology: Japanese Society of Nuclear Medicine working group database.

Authors:  Kenichi Nakajima; Naoya Matsumoto; Tokuo Kasai; Shinro Matsuo; Keisuke Kiso; Koichi Okuda
Journal:  Ann Nucl Med       Date:  2016-02-20       Impact factor: 2.668

8.  Introduction of nuclear medicine research in Japan.

Authors:  Masayuki Inubushi; Tatsuya Higashi; Ichiei Kuji; Setsu Sakamoto; Manabu Tashiro; Mitsuru Momose
Journal:  Eur J Nucl Med Mol Imaging       Date:  2016-08-04       Impact factor: 9.236

Review 9.  IQ·SPECT technology and its clinical applications using multicenter normal databases.

Authors:  Kenichi Nakajima; Koichi Okuda; Mitsuru Momose; Shinro Matsuo; Chisato Kondo; Masayoshi Sarai; Takayuki Shibutani; Masahisa Onoguchi; Takeshi Shimizu; A Hans Vija
Journal:  Ann Nucl Med       Date:  2017-09-22       Impact factor: 2.668

10.  Diagnostic value of thallium-201 myocardial perfusion IQ-SPECT without and with computed tomography-based attenuation correction to predict clinically significant and insignificant fractional flow reserve: A single-center prospective study.

Authors:  Haruki Tanaka; Teruyuki Takahashi; Norihiko Ohashi; Koichi Tanaka; Takenori Okada; Yasuki Kihara
Journal:  Medicine (Baltimore)       Date:  2017-12       Impact factor: 1.817

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.