[Effects of ozurdex on intraocular pressure. A real life clinical practice study].

B Jiménez-Gómez1, M González-Montpetit2, A Fonollosa Calduch2, A Orive Bañuelos2, S Valsero Franco2.   

Abstract

OBJECTIVE: The dexamethasone biodegradable implant, ozurdex, is approved by the US Food and Drug Administration and by the European Medical Agency for the treatment of intermediate and posterior uveitis, and for the treatment of macular edema following retinal vein occlusion and diabetic macular edema. The aim of this study was to assess the effects of intraocular pressure in a cohort of patients from a real-life clinical practice.
METHODS: Retrospective review was performed on the clinical records of patients treated with Ozurdex in Hospital Universitario Cruces in a 6 month period. The following variables were recorded: age, gender, diagnosis and history of glaucoma; intraocular pressure, antihypertensive treatment and macular thickness were recorded before the injection, and in the 1st, 2nd, 4th, and 6th months after the injection. STATISTICAL TESTS: Mann-Whitney U test, Chi square test (with Fisher correction when needed) and Wilcoxon test. The level of statistical significance was set at P<.05.
RESULTS: The effects of 75 injections given to 67 patients (35 women: 52%; mean age: 62) were evaluated. Mean intraocular pressure before the injection was 15.9 mmHg and at 1st, 2nd, 4th and 6th months after de injection it was 18.80 (P=.627), 18.84 (P=.494), 17.02 (P=.796) and 15.5 (P=.829), respectively. No statistically significant differences were observed in intraocular pressure measurements at the mentioned follow-up visits between patients with and without a history of glaucoma.
CONCLUSIONS: In real-life clinical practice, ozurdex shows an excellent safety profile in terms of intraocular hypertension. Patients with a history of glaucoma may also show this profile, with ozurdex being a good option to treat retinal diseases in these patients.
Copyright © 2014 Sociedad Española de Oftalmología. Published by Elsevier España, S.L.U. All rights reserved.

Entities:  

Keywords:  Glaucoma; Intraocular pressure; Ozurdex; Presión intraocular

Mesh:

Substances:

Year:  2015        PMID: 25817950     DOI: 10.1016/j.oftal.2015.01.006

Source DB:  PubMed          Journal:  Arch Soc Esp Oftalmol        ISSN: 0365-6691


  2 in total

1.  Dexamethasone implant in diabetic macular edema in real-life situations.

Authors:  J Chhablani; P Bansal; D Veritti; S Sambhana; V Sarao; F Pichi; P Carrai; D Massaro; A Lembo; A M Mansour; A Banker; S R Gupta; R Hamam; P Lanzetta
Journal:  Eye (Lond)       Date:  2015-11-27       Impact factor: 3.775

2.  Long-term probability of intraocular pressure elevation with the intravitreal dexamethasone implant in the real-world.

Authors:  Javier Zarranz-Ventura; Anna Sala-Puigdollers; Daniel Velazquez-Villoria; Marc Figueras-Roca; Sergio Copete; Laura Distefano; Anna Boixadera; Jose García-Arumi; Alfredo Adan
Journal:  PLoS One       Date:  2019-01-04       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.