BACKGROUND: Carbapenemase-producing Enterobacteriaceae (CPE) have become a major problem for healthcare systems worldwide. While the first reports from European hospitals described the introduction of CPE from endemic countries, there is now a growing number of reports describing outbreaks of CPE in European hospitals. Here we report an outbreak of Carbapenem-resistant K. pneumoniae in a German University hospital which was in part associated to duodenoscopy.
FINDINGS: Between December 6, 2012 and January 10, 2013, carbapenem-resistant K. pneumoniae (CRKP) was cultured from 12 patients staying on 4 different wards. The amplification of carbapenemase genes by multiplex PCR showed presence of the bla OXA-48 gene. Molecular typing confirmed the identity of all 12 isolates. Reviewing the medical records of CRKP cases revealed that there was a spatial relationship between 6 of the cases which were located on the same wards. The remaining 6 cases were all related to endoscopic retrograde cholangiopancreatography (ERCP) which was performed with the same duodenoscope. The outbreak ended after the endoscope was sent to the manufacturer for maintenance.
CONCLUSIONS: Though the outbreak strain was also disseminated to patients who did not undergo ERCP and environmental sources or medical personnel also contributed to the outbreak, the gut of colonized patients is the main source for CPE. Therefore, accurate and stringent reprocessing of endoscopic instruments is extremely important, which is especially true for more complex instruments like the duodenoscope (TJF Q180V series) involved in the outbreak described here.

Entities:  

Keywords:  Carbapenemases; Endoscopy; K. pneumoniae; OXA-48; Outbreak

Year:  2015        PMID: 25815166      PMCID: PMC4374528          DOI: 10.1186/s13756-015-0049-4

Source DB:  PubMed          Journal:  Antimicrob Resist Infect Control        ISSN: 2047-2994            Impact factor:   4.887


Background

Carbapenemase-producing Enterobacteriaceae (CPE) are spreading worldwide, thereby increasing the problem of antimicrobial resistance for clinical and public health [1]. In healthcare facilities, CPE can cause serious infections and hospital outbreaks [2]. There are a few outbreak reports describing the association with duodenoscopy, [3-5] such as the recent outbreak of New Delhi metallo-ß-lactamase (NDM)-producing Escherichia coli transmitted by endoscopic retrograde cholangiopancreatography (ERCP) in Illinois, USA [6,7]. Here we report an outbreak of Klebsiella pneumoniae producing the oxacillinase-48 (OXA-48) carbapenemase which took place in Charité University Medicine, Berlin, a tertiary hospital with 139.000 hospital admissions a year. Between December 6, 2012 and January 10, 2013, carbapenem-resistant K. pneumoniae (CRKP) was cultured from 5 patients staying on ward A. The patients were immediately transferred to single rooms or cohorted in shared rooms. Contact isolation precautions were taken for all 5 patients. Active surveillance screening for CRKP was introduced for all patients admitted to ward A and environmental samples from surfaces, medical devices, drugs, water, cleaning solutions, disinfectants etc. were taken. Neither the active surveillance nor the environmental samples revealed any further positive results for CRKP on ward A. It was 4 weeks after the last CRKP was detected on ward A, when another 5 cases of CRKP emerged on different locations of the hospital: On ward B, there were 3 patients and on wards C and D each one further patient with CRKP-positive results.

Methods

The medical records of patients with CRKP were reviewed. As four patients (one from ward A, one from ward B and the two single patients from wards C and D) underwent duodenoscopy for ERCP, the endoscopy records were also inspected. From December 10, 2012 (after the second patient had been tested positive for CRKP) Patients who were admitted to wards A and B or underwent duodenoscopy using one specific instrument (TJF Q180V series) were screened for rectal CRKP colonization. In addition, the environment and all duodenoscopes of the endoscopy unit were sampled. CRKP screening of patients was performed by plating rectal swabs on selective culture media containing cefpodoxime (ChromID ESBL, bioMerieux) and on MacConkey plates on which an ertapenem disk (10 μg) was placed. Swabs taken for environmental sampling were enriched in trypticase soy broth (TSB) for 7 days at 37°C. Liquid samples were filtered through 0.2 μm cellulose membrane filters which were enriched in TSB for 7 days at 37°C. Disinfectants and soaps (1 mL) were transferred to TSB containing neutralizers (3% Tween 80, 3% saponin, 0.1% histidin, 0.1% cystein). Subsequently, the enriched TSB samples were cultured on Columbia and MacConkey plates. Duodenoscopes were sampled by flushing each channel with 20 ml of sterile saline solution and swabbing the ends of the channels. A 10 mL sample of the flushing solution was neutralized and filtered. Filters and swabs were processed as described above. Species identification and susceptibility testing was done using a VITEK 2 system. For detection of carbapenemase genes, a multiplex polymerase chain reaction (PCR) containing primers for blaOXA-48, blaBIC, blaNDM and blaKPC was performed [8]. Strain typing of CRKP was done by comparison of XbaI macro restriction profiles generated by pulsed field gel electrophoresis (PFGE) according to the criteria of Tenover [9].

Results

An overview of the spatial and temporal relationship and the characteristics of the patients is given in Figure 1 and Table 1, respectively.
Figure 1

Description of the CRKP outbreak and its association to duodenoscopy. Legend: 1–12: Case number; Grey bars: Duration of hospital stay; +: Isolation of CRKP; D: Duodenoscopy.

Table 1

Characteristics of CRKP cases

Patient Gender Age (years) Date of positive CRKP sample Source Infection/colonization Ward Date of duodenoscopy
1m7106/12/12Tracheobronchial secretionRespiratory tract infectionA-
2m2010/12/12Rectal swabSepticemiaA-
3m2527/12/12Rectal swabSepticemiaA08/02/13
4f3430/12/12Blood cultureSepticemiaA-
5f7210/01/13Rectal swabColonizationA-
6m5813/02/13Blood cultureSepticemiaB12/02/13
7f3214/02/13Intra-abdominal swabSepticemiaB-
8m5718/02/13Rectal swabColonizationB-
9m2618/02/13Rectal swabSurgical site infectionC12/02/13
10m3926/02/13Rectal swabRespiratory tract infectionD20/02/12
11m4314/03/13Rectal swabSepticemiaE13/02/13
12f6124/03/13Rectal swabColonizationF20/02/13
Description of the CRKP outbreak and its association to duodenoscopy. Legend: 1–12: Case number; Grey bars: Duration of hospital stay; +: Isolation of CRKP; D: Duodenoscopy. Characteristics of CRKP cases Reviewing the endoscopy records of the four CRKP positive patients who underwent ERCP revealed that the same duodenoscope had been used in all of them. The flushing solutions and swabs from the respective duodenoscope grew no additional CRKP, nor did the samples from the other duodenoscopes or the environment of the endoscopy unit. Only enterococci were cultured from the flushing solution of one of the other duodenoscopes. The review of the endoscope records identified 22 additional patients who underwent ERCP with the respective duodenoscope, of which 19 were available for rectal screening. From two of these patients, CRKP were recovered from the rectal swabs. Typing of the 12 CRKP strains (5 from ward A, 3 from ward B and the 4 single patients who underwent ERCP) revealed that they were closely related (less than 3 bands difference in PFGE). The amplification of carbapenemase genes by multiplex PCR showed presence of the blaOXA-48 gene. Apart from the ERCP procedure using the same duodenoscope, the review of the medical records did not develop any further linkage between the patients from wards A and B and the four single CRKP cases.

Discussion

In our hypothesis, CRKP were first introduced to ward A by patient 1 as part of the patient’s gut flora and then transmitted to patients 2 – 5 on ward A, most probably by contact (either by the hands of staff members or by contaminated medical devices or surfaces). Subsequently, one of these patients (patient 3) underwent ERCP, which led to contamination of the duodenoscope and the transmission of CRKP to patient 6, who acted as the source of transmission of CRKP to the patients 7 and 8 on ward B. The contaminated duodenoscope is also thought to have transmitted CRKP to four additional patients (patients 9 to 12), who all underwent ERCP using the same endoscope. Although culturing of the duodenoscope did not recover CRKP, this does not exclude its association with CRKP transmission. While recommended for surveillance testing of endoscope reprocessing in the German guidelines, [10] flushing of the instrument channels with NaCl may not be sensitive enough to discover endoscope contamination [11] – particularly after the instrument was reprocessed several times before sampling such as in this case. Additionally brushing the endoscope channels might have been the method of choice to prove contamination with the respective outbreak strain of CRKP [12], but the instrument was sent to the manufacturer for maintenance before it could be probed again. Nevertheless, there are several epidemiological hints pointing to the duodenoscope as source of the CRKP-transmission: i) duodenoscopy using the instrument in question was the only epidemiological link between patients from different wards ii) following duodenoscopy, CRKP were only cultured if the implicated instrument was used iii) after the instrument in question was sent for maintenance (which revealed defects of the external layers and the distal cap of the respective duodenoscope), no further CRKP were cultured. Reviewing the complete reprocessing operation in our endoscopy unit, we could not identify any deviations from the procedures recommended by the manufacturer of the duodenoscope. However, in one instance enterococci were cultured from one of the reprocessed duodenoscopes, which are indicative for insufficient cleaning and disinfection [10]. Therefore, the reprocessing procedures were not in every case sufficient, most probably due to the complex physical design of the endoscope’s distal end which complicated reprocessing as additional manual steps had to be performed strictly complying with the manufacturer’s advice: The distal cap of the duodenoscope was not removable and required accurate manual brushing and locking of the forceps elevator at 45° before automated reprocessing could be done. Recently, an outbreak of NDM-producing E. coli associated with ERCP which ended after the duodenoscopes were sterilized with ethylene oxide was published [6,7]. The authors concluded that ERCP-related transmission should be considered in case of an outbreak with CPE, as the complex design of duodenoscopes “might pose a particular challenge for cleaning and disinfection” [6] and makes cleaning difficult. This conclusion is supported by a recent review which identified gastrointestinal endoscopy to be a risk factor for infection and colonization with CPE [13]. The complex physical design of the endoscope’s distal end could also have contributed to the outbreak described here, as it required strict adherence to the procedures recommended by the manufacturer. In a recent safety communication the U.S. Food And Drug Administration states that the transmission of microorganisms may even occur when manufacturer reprocessing instructions are followed correctly and, therefore, is continuing to evaluate information about documented and potential infections due to duodenoscopic instruments. In the meantime, patients should be informed about the potential risks of duodenoscopy including infections due to transmission [14]. Though the outbreak strain was also disseminated to patients who did not undergo ERCP and environmental sources or medical personnel contributed to the outbreak on wards A and B, the gut of colonized patients is the main source for CPE. Therefore, accurate and stringent reprocessing of endoscopic instruments is extremely important to prevent the transmission of multidrug resistant organisms or blood borne viruses – in particular, when more complex endoscopic instruments are involved as in the outbreak described here.
  13 in total

1.  Endoscopy-associated transmission of carbapenem-resistant Klebsiella pneumoniae producing KPC-2 beta-lactamase.

Authors:  Thierry Naas; Gaelle Cuzon; Adrien Babics; Nicolas Fortineau; Isabelle Boytchev; François Gayral; Patrice Nordmann
Journal:  J Antimicrob Chemother       Date:  2010-04-09       Impact factor: 5.790

2.  Multidrug-resistant Klebsiella pneumoniae outbreak after endoscopic retrograde cholangiopancreatography.

Authors:  C Aumeran; L Poincloux; B Souweine; F Robin; H Laurichesse; O Baud; G Bommelaer; O Traoré
Journal:  Endoscopy       Date:  2010-08-19       Impact factor: 10.093

3.  Carbapenem-resistant Enterobacteriaceae: a potential threat.

Authors:  Mitchell J Schwaber; Yehuda Carmeli
Journal:  JAMA       Date:  2008-12-24       Impact factor: 56.272

4.  [Hygiene requirements for the reprocessing of medical devices. Recommendation of the Commission for Hospital Hygiene and Infection Prevention (KRINKO) at the Robert Koch Institute (RKI) and the Federal Institute for Drugs and Medical Devices (BfArM)].

Authors: 
Journal:  Bundesgesundheitsblatt Gesundheitsforschung Gesundheitsschutz       Date:  2012-10       Impact factor: 1.513

5.  Multiplex PCR for detection of acquired carbapenemase genes.

Authors:  Laurent Poirel; Timothy R Walsh; Vincent Cuvillier; Patrice Nordmann
Journal:  Diagn Microbiol Infect Dis       Date:  2011-03-12       Impact factor: 2.803

Review 6.  Interpreting chromosomal DNA restriction patterns produced by pulsed-field gel electrophoresis: criteria for bacterial strain typing.

Authors:  F C Tenover; R D Arbeit; R V Goering; P A Mickelsen; B E Murray; D H Persing; B Swaminathan
Journal:  J Clin Microbiol       Date:  1995-09       Impact factor: 5.948

Review 7.  Interventional strategies and current clinical experience with carbapenemase-producing Gram-negative bacteria.

Authors:  M Akova; G L Daikos; L Tzouvelekis; Y Carmeli
Journal:  Clin Microbiol Infect       Date:  2012-05       Impact factor: 8.067

8.  New Delhi metallo-β-lactamase-producing carbapenem-resistant Escherichia coli associated with exposure to duodenoscopes.

Authors:  Lauren Epstein; Jennifer C Hunter; M Allison Arwady; Victoria Tsai; Linda Stein; Marguerite Gribogiannis; Mabel Frias; Alice Y Guh; Alison S Laufer; Stephanie Black; Massimo Pacilli; Heather Moulton-Meissner; J Kamile Rasheed; Johannetsy J Avillan; Brandon Kitchel; Brandi M Limbago; Duncan MacCannell; David Lonsway; Judith Noble-Wang; Judith Conway; Craig Conover; Michael Vernon; Alexander J Kallen
Journal:  JAMA       Date:  2014-10-08       Impact factor: 56.272

Review 9.  Risk of transmission of carbapenem-resistant Enterobacteriaceae and related "superbugs" during gastrointestinal endoscopy.

Authors:  Lawrence F Muscarella
Journal:  World J Gastrointest Endosc       Date:  2014-10-16

Review 10.  Transmission of infection by flexible gastrointestinal endoscopy and bronchoscopy.

Authors:  Julia Kovaleva; Frans T M Peters; Henny C van der Mei; John E Degener
Journal:  Clin Microbiol Rev       Date:  2013-04       Impact factor: 26.132

View more
  33 in total

Review 1.  Duodenoscope-Associated Infections: Update on an Emerging Problem.

Authors:  M Rubayat Rahman; Abhilash Perisetti; Roxana Coman; Pardeep Bansal; Rajiv Chhabra; Hemant Goyal
Journal:  Dig Dis Sci       Date:  2018-12-19       Impact factor: 3.199

2.  Is This the Carbapenemase Test We've Been Waiting for? A Multicenter Evaluation of the Modified Carbapenem Inactivation Method.

Authors:  Susan M Butler-Wu; April N Abbott
Journal:  J Clin Microbiol       Date:  2017-06-14       Impact factor: 5.948

3.  Findings from an outbreak of carbapenem-resistant Klebsiella pneumoniae emphasize the role of antibiotic treatment for cross transmission.

Authors:  Stefan Borgmann; Yvonne Pfeifer; Laura Becker; Beate Rieß; Rabea Siegmund; Ulrich Sagel
Journal:  Infection       Date:  2017-11-24       Impact factor: 3.553

Review 4.  Current Practice of Duodenoscope Reprocessing.

Authors:  Stephen Kim; V Raman Muthusamy
Journal:  Curr Gastroenterol Rep       Date:  2016-10

Review 5.  Hygiene: The Looming Achilles Heel in Endoscopy.

Authors:  Michael Jung; Ulrike Beilenhoff
Journal:  Visc Med       Date:  2016-02-10

6.  Outbreak column 18: The undervalued work of outbreak: prevention, preparedness, detection and management.

Authors:  Evonne T Curran; Catherine E Dalziel
Journal:  J Infect Prev       Date:  2015-08-12

Review 7.  Duodenoscope-associated infections: a review.

Authors:  Gheorghe G Balan; Catalin Victor Sfarti; Stefan Andrei Chiriac; Carol Stanciu; Anca Trifan
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2019-09-03       Impact factor: 3.267

8.  A Semi-Synthetic Glycoconjugate Vaccine Candidate for Carbapenem-Resistant Klebsiella pneumoniae.

Authors:  Peter H Seeberger; Claney L Pereira; Naeem Khan; Guozhi Xiao; Elizabeth Diago-Navarro; Katrin Reppe; Bastian Opitz; Bettina C Fries; Martin Witzenrath
Journal:  Angew Chem Int Ed Engl       Date:  2017-10-05       Impact factor: 15.336

9.  A Systematic Review and Meta-analyses of the Clinical Epidemiology of Carbapenem-Resistant Enterobacteriaceae.

Authors:  Karlijn van Loon; Anne F Voor In 't Holt; Margreet C Vos
Journal:  Antimicrob Agents Chemother       Date:  2017-12-21       Impact factor: 5.191

Review 10.  OXA-48-like carbapenemases producing Enterobacteriaceae in different niches.

Authors:  Assia Mairi; Alix Pantel; Albert Sotto; Jean-Philippe Lavigne; Aziz Touati
Journal:  Eur J Clin Microbiol Infect Dis       Date:  2017-10-08       Impact factor: 3.267

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.