Literature DB >> 25801581

Looped versus single-stranded flexor tendon repairs: a cadaveric mechanical study.

Ryan P Calfee1, Sean Boone2, Jeffrey G Stepan2, Daniel A Osei2, Stavros Thomopoulos2, Martin I Boyer2.   

Abstract

PURPOSE: To compare the tensile properties of 4-strand modified Kessler flexor tendon repairs using a looped or single-stranded suture.
METHODS: We evaluated the mechanical properties of 4-strand Kessler zone II core suture repairs using either looped or single-stranded suture in human flexor digitorum profundus and flexor pollicis longus tendons. Forty repairs were performed on tendons from bilateral cadaveric hands: 20 matched tendons were divided into equal groups of 3-0 looped and 3-0 single-strand repairs and 20 additional matched tendons were divided into equal groups of 4-0 looped and 4-0 single-strand repairs. Repaired tendons were tested in uniaxial tension to failure to determine mechanical properties and failure modes. Data were analyzed to determine the effect of repair type (ie, looped vs single-stranded) for each suture caliber (ie, 3-0 and 4-0).
RESULTS: Single-strand repairs with 3-0 suture demonstrated a significantly greater maximum load to failure and a significantly higher force at 2-mm gap compared with repairs with looped 3-0 suture. All 8 looped repairs with 3-0 suture failed by suture pullout whereas 7 of 8 repairs with 3-0 single-stranded suture failed by suture breakage. The mechanical properties of looped versus single-stranded repairs with 4-0 caliber suture were not statistically different. Repairs with 4-0 caliber suture failed by suture breakage in 8 of 10 single-strand repairs and failed by suture pullout in 6 of 10 repairs with looped suture.
CONCLUSIONS: In a time-0 ex vivo human cadaveric core suture model, the mechanical properties of a 4-strand repair using 3-0 single-stranded suture were significantly better than the same 4-strand repair performed with looped suture. CLINICAL RELEVANCE: Four-strand flexor tendon repairs with 3-0 suture are mechanically superior when performed with single-strand suture versus looped suture.
Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Flexor tendon; looped; repair; zone II

Mesh:

Year:  2015        PMID: 25801581      PMCID: PMC4428313          DOI: 10.1016/j.jhsa.2015.01.035

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  19 in total

1.  Effect of suture locking and suture caliber on fatigue strength of flexor tendon repairs.

Authors:  K A Barrie; S L Tomak; J Cholewicki; G A Merrell; S W Wolfe
Journal:  J Hand Surg Am       Date:  2001-03       Impact factor: 2.230

2.  Biomechanical evaluation of double-strand (looped) and single-strand polyamide multifilament suture: influence of knot and suture size.

Authors:  David T Netscher; Justin J Badal; Jonathan Yang; Yoav Kaufman; Jerry Alexander; Philip Noble
Journal:  Hand (N Y)       Date:  2015-09

3.  Biomechanical evaluation of a four-strand modification of the Tang method of tendon repair.

Authors:  Y Cao; J B Tang
Journal:  J Hand Surg Br       Date:  2005-08

4.  Effect of peripheral suture depth on strength of tendon repairs.

Authors:  E Diao; J S Hariharan; O Soejima; J C Lotz
Journal:  J Hand Surg Am       Date:  1996-03       Impact factor: 2.230

5.  The effects of multiple-strand suture methods on the strength and excursion of repaired intrasynovial flexor tendons: a biomechanical study in dogs.

Authors:  S C Winters; R H Gelberman; S L Woo; S S Chan; R Grewal; J G Seiler
Journal:  J Hand Surg Am       Date:  1998-01       Impact factor: 2.230

6.  The locking loop tendon suture.

Authors:  D G Pennington
Journal:  Plast Reconstr Surg       Date:  1979-05       Impact factor: 4.730

7.  The effect of gap formation at the repair site on the strength and excursion of intrasynovial flexor tendons. An experimental study on the early stages of tendon-healing in dogs.

Authors:  R H Gelberman; M I Boyer; M D Brodt; S C Winters; M J Silva
Journal:  J Bone Joint Surg Am       Date:  1999-07       Impact factor: 5.284

8.  Intrasynovial flexor tendon repair: a biomechanical study of variations in suture application in human cadavera.

Authors:  Gregory N Nelson; Ryan Potter; Eleni Ntouvali; Matthew J Silva; Martin I Boyer; Richard H Gelberman; Stavros Thomopoulos
Journal:  J Orthop Res       Date:  2012-03-27       Impact factor: 3.494

9.  A biomechanical analysis of suture materials and their influence on a four-strand flexor tendon repair.

Authors:  Tom M Lawrence; Tim R C Davis
Journal:  J Hand Surg Am       Date:  2005-07       Impact factor: 2.230

10.  The effect of suture caliber and number of core suture strands on zone II flexor tendon repair: a study in human cadavers.

Authors:  Daniel A Osei; Jeffrey G Stepan; Ryan P Calfee; Stavros Thomopoulos; Martin I Boyer; Ryan Potter; Richard H Gelberman
Journal:  J Hand Surg Am       Date:  2013-12-15       Impact factor: 2.230

View more
  1 in total

1.  [Suture techniques and material in surgery of flexor tendons].

Authors:  T Pillukat; R Fuhrmann; J Windolf; J van Schoonhoven
Journal:  Chirurg       Date:  2017-03       Impact factor: 0.955

  1 in total