| Literature DB >> 25799311 |
Daniel O Stram1, Dale L Preston2, Mikhail Sokolnikov3, Bruce Napier4, Kenneth J Kopecky5, John Boice6, Harold Beck7, John Till8, Andre Bouville9.
Abstract
Radiation dose reconstruction systems for large-scale epidemiological studies are sophisticated both in providing estimates of dose and in representing dosimetry uncertainty. For example, a computer program was used by the Hanford Thyroid Disease Study to provide 100 realizations of possible dose to study participants. The variation in realizations reflected the range of possible dose for each cohort member consistent with the data on dose determinates in the cohort. Another example is the Mayak Worker Dosimetry System 2013 which estimates both external and internal exposures and provides multiple realizations of "possible" dose history to workers given dose determinants. This paper takes up the problem of dealing with complex dosimetry systems that provide multiple realizations of dose in an epidemiologic analysis. In this paper we derive expected scores and the information matrix for a model used widely in radiation epidemiology, namely the linear excess relative risk (ERR) model that allows for a linear dose response (risk in relation to radiation) and distinguishes between modifiers of background rates and of the excess risk due to exposure. We show that treating the mean dose for each individual (calculated by averaging over the realizations) as if it was true dose (ignoring both shared and unshared dosimetry errors) gives asymptotically unbiased estimates (i.e. the score has expectation zero) and valid tests of the null hypothesis that the ERR slope β is zero. Although the score is unbiased the information matrix (and hence the standard errors of the estimate of β) is biased for β≠0 when ignoring errors in dose estimates, and we show how to adjust the information matrix to remove this bias, using the multiple realizations of dose. The use of these methods in the context of several studies including, the Mayak Worker Cohort, and the U.S. Atomic Veterans Study, is discussed.Entities:
Mesh:
Year: 2015 PMID: 25799311 PMCID: PMC4370375 DOI: 10.1371/journal.pone.0119418
Source DB: PubMed Journal: PLoS One ISSN: 1932-6203 Impact factor: 3.240
Fig 1Noncentrality and Power.
Points indicate effects assuming no sharing of errors, dashes include the shared error effects. For reference the dotted lines show noncentrality parameters and power assuming that true dose rather than estimated dose was available for the study. Results are particular to the AVS data described herein.
Fig 2Effect of accounting for shared dosimetry errors on the length of standard errors in the high-sided calculations performed for the AVS study.
The two dashed lines are based on ordinary least squares calculations and show the upper and lower bounds of a "naïve" confidence interval for slope parameter b (normalized by residual standard deviation, σ) ignoring inhomogeneous or shared errors. The solid lines show the effect of accounting for both inhomogeneous and shared error in expanding the confidence limits. The dot-dash lines between the dashed and solid lines shows the effect of adjusting for inhomogeneous errors but where there are no shared errors (off diagonals of matrix K are zero).