Literature DB >> 25794918

Clinical marginal and internal fit of metal ceramic crowns fabricated with a selective laser melting technology.

Zhuoli Huang1, Lu Zhang2, Jingwei Zhu1, Xiuyin Zhang3.   

Abstract

STATEMENT OF PROBLEM: Selective laser melting (SLM) technology has been introduced to fabricate dental restorations. However, the fit of these restorations still needs further study.
PURPOSE: The purpose of this in vivo investigation was to compare the marginal and internal fit of SLM metal ceramic crowns with 2 lost-wax cast metal ceramic crowns and to evaluate the influence of tooth type on the marginal and internal fit of these crowns.
MATERIAL AND METHODS: A total of 330 metal ceramic crowns were evaluated. The metal copings were fabricated with SLM Co-Cr, cast Au-Pt, and cast Co-Cr alloy (n=110). The marginal and internal gaps of crowns were recorded by using a replica technique. The anterior and premolar replicas were sectioned 2 times, and molar replicas were sectioned 4 times. The marginal and internal gap width of each cross section was examined by stereomicroscope at ×30 magnification. Two-way analysis of variance was performed to identify the statistical difference among the groups.
RESULTS: The marginal fit of the SLM Co-Cr group (75.6 ±32.6 μm) was not different from the cast Au-Pt group (76.8 ±32.1 μm) (P>.05) but was better than the cast Co-Cr group (91.0 ±36.3 μm) (P<.01). No significant difference was found among the SLM Co-Cr group (127.3 ±45.8 μm), cast Au-Pt group (129.9 ±61.1 μm). and cast Co-Cr group (142.5 ±63.7 μm) (P>.05). The mean occlusal gap width of the SLM Co-Cr group (309.8 ±106.6 μm) was significantly higher than that of the cast Au-Pt group (254.6 ±109.6 μm) and the cast Co-Cr group (249.6 ±110.4 μm) (P<.005). No significant difference was found in the marginal fit among the anterior group (84.4 ±35.1 μm), the premolar group (80.6 ±26.3 μm), and the molar group (82.7 ±38.0 μm) (P>.05). Also, no significant difference was found in the axial fit among the anterior group (138.3 ±52.5 μm), the premolar group (132.9 ±50.4 μm), and the molar group (134.4 ±52.5 μm) (P>.05). The anterior group (267.6 ±110.2 μm) did not differ from the premolar group (270.2 ±112.8 μm) and the molar group (268.6 ±110.5 μm) in occlusal fit (P>.05).
CONCLUSIONS: The marginal fit of SLM Co-Cr metal ceramic crowns was similar to that of the cast Au-Pt metal ceramic crowns and was better than that of the cast Co-Cr metal ceramic crowns. The SLM Co-Cr metal ceramic crowns were not significantly different from the 2 cast metal ceramic crowns in axial fit but were less accurate in occlusal fit. Tooth type did not influence the marginal and internal fit of the metal ceramic crowns.
Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25794918     DOI: 10.1016/j.prosdent.2014.10.012

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  9 in total

1.  Fracture load of 3D-printed fixed dental prostheses compared with milled and conventionally fabricated ones: the impact of resin material, build direction, post-curing, and artificial aging-an in vitro study.

Authors:  Marcel Reymus; Rosalie Fabritius; Andreas Keßler; Reinhard Hickel; Daniel Edelhoff; Bogna Stawarczyk
Journal:  Clin Oral Investig       Date:  2019-05-24       Impact factor: 3.573

2.  Fit of cobalt-chromium copings fabricated by the selective laser melting technology and casting method: A comparative evaluation using a profilometer.

Authors:  Koosha Gholamrezaei; Fariborz Vafaee; Behzad Fathi Afkari; Farnaz Firouz; Mozhgan Seif
Journal:  Dent Res J (Isfahan)       Date:  2020-05-23

3.  Comparative Evaluation of Two Different Types of Abutments in Relation to Post-prosthetic Bone Resorption and Periodontal Pocket Depth: A Randomized Controlled Clinical Trial With a One-Year Follow-Up.

Authors:  Mohammad Anas Almodalal; Mhd Luai Morad; Mohammad Y Hajeer; Munir Harfouche
Journal:  Cureus       Date:  2022-06-10

Review 4.  A systematic review on the accuracy of zirconia crowns and fixed dental prostheses.

Authors:  Per Svanborg
Journal:  Biomater Investig Dent       Date:  2020-01-07

5.  The Impact of Sintering Technology and Milling Technology on Fitting Titanium Crowns to Abutment Teeth-In Vitro Studies.

Authors:  Wojciech Ryniewicz; Łukasz Bojko; Anna M Ryniewicz
Journal:  Materials (Basel)       Date:  2022-08-24       Impact factor: 3.748

Review 6.  3D Printing in Digital Prosthetic Dentistry: An Overview of Recent Developments in Additive Manufacturing.

Authors:  Josef Schweiger; Daniel Edelhoff; Jan-Frederik Güth
Journal:  J Clin Med       Date:  2021-05-07       Impact factor: 4.964

7.  Influence of Manufacturing Methods of Implant-Supported Crowns on External and Internal Marginal Fit: A Micro-CT Analysis.

Authors:  Izabela C M Moris; Silas Borges Monteiro; Raíssa Martins; Ricardo Faria Ribeiro; Erica A Gomes
Journal:  Biomed Res Int       Date:  2018-01-23       Impact factor: 3.411

8.  Cobalt-chromium alloys in fixed prosthodontics in Sweden.

Authors:  Maria Kassapidou; Victoria Franke Stenport; Lars Hjalmarsson; Carina B Johansson
Journal:  Acta Biomater Odontol Scand       Date:  2017-08-11

Review 9.  A systematic review on the accuracy of manufacturing techniques for cobalt chromium fixed dental prostheses.

Authors:  Per Svanborg; Lars Hjalmarsson
Journal:  Biomater Investig Dent       Date:  2020-01-20
  9 in total