Literature DB >> 25790154

A pilot study examining density of suppression measurement in strabismus.

Marianne Piano1, David Newsham.   

Abstract

PURPOSE: Establish whether the Sbisa bar, Bagolini filter (BF) bar, and neutral density filter (NDF) bar, used to measure density of suppression, are equivalent and possess test-retest reliability. Determine whether density of suppression is altered when measurement equipment/testing conditions are changed.
METHODS: Our pilot study had 10 subjects aged ≥18 years with childhood-onset strabismus, no ocular pathologies, and no binocular vision when manifest. Density of suppression upon repeated testing, with clinic lights on/off, and using a full/reduced intensity light source, was investigated. Results were analysed for test-retest reliability, equivalence, and changes with alteration of testing conditions.
RESULTS: Test-retest reliability issues were present for the BF bar (median 6 filter change from first to final test, p = 0.021) and NDF bar (median 5 filter change from first to final test, p = 0.002). Density of suppression was unaffected by environmental illumination or fixation light intensity variations. Density of suppression measurements were higher when measured with the NDF bar (e.g. NDF bar = 1.5, medium suppression, vs BF bar = 6.5, light suppression).
CONCLUSIONS: Test-retest reliability issues may be present for the two filter bars currently still under manufacture. Changes in testing conditions do not significantly affect test results, provided the same filter bar is used consistently for testing. Further studies in children with strabismus having active amblyopia treatment would be of benefit. Despite extensive use of these tests in the UK, this is to our knowledge the first study evaluating filter bar equivalence/reliability.

Entities:  

Keywords:  Amblyopia; binocular vision; strabismus; suppression

Mesh:

Year:  2015        PMID: 25790154     DOI: 10.3109/09273972.2014.1002621

Source DB:  PubMed          Journal:  Strabismus        ISSN: 0927-3972


  11 in total

1.  Testing depth of suppression in childhood intermittent exotropia.

Authors:  Sarah R Hatt; David A Leske; Jonathan M Holmes; Robert J Henderson; Danielle L Chandler; David G Morrison; Allison I Summers; Susan A Cotter
Journal:  J AAPOS       Date:  2021-11-16       Impact factor: 1.220

2.  Reduced Monocular Luminance Increases Monocular Temporal Synchrony Threshold in Human Adults.

Authors:  Ling Gong; Seung Hyun Min; Shijia Chen; Junhan Wei; Deying Kong; Chunwen Tao; Peng Zhang; Pi-Chun Huang; Jiawei Zhou
Journal:  Invest Ophthalmol Vis Sci       Date:  2020-07-01       Impact factor: 4.799

3.  The Binocular Balance at High Spatial Frequencies as Revealed by the Binocular Orientation Combination Task.

Authors:  Yonghua Wang; Zhifen He; Yunjie Liang; Yiya Chen; Ling Gong; Yu Mao; Xiaoxin Chen; Zhimo Yao; Daniel P Spiegel; Jia Qu; Fan Lu; Jiawei Zhou; Robert F Hess
Journal:  Front Hum Neurosci       Date:  2019-04-02       Impact factor: 3.169

4.  Patching and Suppression in Amblyopia: One Mechanism or Two?

Authors:  Yiya Chen; Zhifen He; Yu Mao; Hao Chen; Jiawei Zhou; Robert F Hess
Journal:  Front Neurosci       Date:  2020-01-15       Impact factor: 4.677

5.  Contrast Rivalry Paradigm Reveals Suppression of Monocular Input in Keratoconus.

Authors:  Bhagya Lakshmi Marella; Miriam L Conway; Catherine Suttle; Shrikant R Bharadwaj
Journal:  Invest Ophthalmol Vis Sci       Date:  2021-02-01       Impact factor: 4.799

6.  Stimulus dependence of interocular suppression.

Authors:  Wei Hau Lew; Scott B Stevenson; Daniel R Coates
Journal:  Sci Rep       Date:  2021-04-29       Impact factor: 4.379

7.  A clinically convenient test to measure binocular balance across spatial frequency in amblyopia.

Authors:  Seung Hyun Min; Yu Mao; Shijia Chen; Zhifen He; Robert F Hess; Jiawei Zhou
Journal:  iScience       Date:  2021-12-18

8.  Worth 4 Dot App for Determining Size and Depth of Suppression.

Authors:  Ann L Webber; Thomas R Mandall; Darcy T Molloy; Lucas J Lister; Eileen E Birch
Journal:  Transl Vis Sci Technol       Date:  2020-03-09       Impact factor: 3.283

9.  Interocular ND filter suppression: Eccentricity and luminance polarity effects.

Authors:  Akash S Chima; Monika A Formankiewicz; Sarah J Waugh
Journal:  J Vis       Date:  2020-07-01       Impact factor: 2.240

10.  Quantifying Suppression in Anisometropic Amblyopia With VTS4 (Vision Therapy System 4).

Authors:  Shivalika Sehgal; PremNandhini Satgunam
Journal:  Transl Vis Sci Technol       Date:  2020-11-19       Impact factor: 3.283

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.