Literature DB >> 25780541

Randomized double-blind clinical trial of eutectic mixture of local anesthetic creams in reducing pain during hysterosalpingography.

Mojgan Kalantari1, Shahrzad Zadeh Modares2, Firoozeh Ahmadi3, Vajihe Hazari4, Hadieh Haghighi3, Mohammad Chehrazi5, Melika Razaghi6.   

Abstract

BACKGROUND: Hysterosalpingography (HSG) is considered as a primary test in infertility work up worldwide due to its reliability in evaluating abnormalities related to the uterus and fallopian tubes.
OBJECTIVES: To assess the efficacy of applying eutectic mixture of local anesthetics (lidocaine-prilocaine cream) (EMLA) on the uterine cervix in reducing pain during HSG. PATIENTS AND METHODS: Eighty patients undergoing HSG as part of infertility evaluation were randomly allocated to groups receiving either EMLA (N = 40) or placebo cream (N = 40) in a double-blinded prospective study. Fifteen minutes before HSG, 5 grams of 5% cream was applied to the uterine cervix using a cervical applicator. The degree of pain experienced by the patient was evaluated during and after HSG at five predefined steps on a visual analogue scale (VAS).
RESULTS: There was no significant difference in the efficacy between EMLA and placebo creams in pain perception during the entire procedure. There was no significant difference in long term pain perception half an hour after the HSG performance.
CONCLUSIONS: This study does not support the use of EMLA for HSG.

Entities:  

Keywords:  Eutectic Lidocaine-Prilocaine; Hysterosalpingography; Pain; Visual Analog Scale

Year:  2014        PMID: 25780541      PMCID: PMC4347756          DOI: 10.5812/iranjradiol.10513

Source DB:  PubMed          Journal:  Iran J Radiol        ISSN: 1735-1065            Impact factor:   0.212


1. Background

Hysterosalpingography (HSG) is considered as a primary test in infertility work up worldwide due to its reliability in evaluating abnormalities related to the uterus and fallopian tubes. Despite rare complications, lower abdominal pain is found as the patient’s main complaint during and after test performance (1). A number of techniques have been introduced to reduce the severity of pain, including substituting balloon catheter instead of a metal canola or using water based contrast media (2-5). Pain medications before and during HSG such as oral non-steroidal anti-inflammatory drugs or intravenous opioid analgesics have also been used (6, 7). Topical pain medication and local anesthetics either inserted into the uterus or applied on the uterine cervix before the procedure have been also examined in different studies (8, 9). Liberty et al. reported that eutectic mixture of local anesthetics (lidocaine-prilocaine) (EMLA) applied on the cervix significantly decreased discomfort during cervical instrumentation, which is found as the most painful step, and no complication was declared (1). With increased demand for HSG, mainly due to advances in reproductive medicine, there is an increasing need to introduce a safe and effective medication and technique to reduce pain during this procedure.To the best of our knowledge, this is the first study using ELMA among Iranian infertile women.

2. Objectives

The objective of this study was to assess the efficacy of the topical anesthetic (lidocaine 2.5%/prilocaine 2.5%) combination cream to reduce pain during and after HSG at five predefined steps (speculum application, cervical instrumentation of the tenaculum and cannula, at the end of uterine filling, speculum and cannula withdrawal and 30 minutes after the procedure).

3. Patients and Methods

This was a randomized double-blind clinical trial conducted from January 2011 to March 2012 at Mahdieh Hospital in Tehran. The study population consisted of women who were referred to the department of radiology for HSG during infertility investigation. Patients were considered eligible if: 1) They were alert, orientated and cooperative to response to the visual analogue scale (VAS). 2) They signed the informed consent to participate in the clinical trial before entering the study. Patients were excluded if: 1) They had a history of hypersensitivity to local anesthetics or were strictly prohibited to use local anesthetics. 2) They had used oral analgesics before the procedure. 3) They had a history of chronic pelvic pain or dysmenorrhea. 4) They could not cooperate or if there was any problem during the procedure such as difficulty in instrument application or difficulty in uterine expansion when there was need for more contrast injection. A statistical type I error (alpha) of 0.05, power of 80%, mean difference of 1.6 in VAS (4.9 for the placebo group vs. 3.3 for the EMLA group) and an equal standard deviation of 2.5 for both groups altogether yielded a sample size of 40 in each group. Eighty-four women were assessed for eligibility; four were excluded from the study, two for stenosis of the internal cervical os and two because they used oral analgesics before the procedure. A 10-point VAS (0 = no pain and 10 = severe pain) was used to represent the level of perceived pain intensity by patients. All patients were asked to sign a written consent after they were informed clearly about the HSG procedure, study design and VAS and its application. VAS is a unidimensional pain scale, first developed by Woodforde and Merskey (10). It is one of the most commonly accepted measures for the assessment of pain intensity (11). Traditionally, VAS consisted of a 100-mm horizontal line and the participant was asked to mark the line at the point that represents pain intensity (0 = no pain and 10 = pain as bad as it could possibly be), the score determined by using a ruler and measuring the distance from 0 to the patient’s mark, providing a range of scores from 0 to 10, on a white loose leaf of paper. Paper and pencil administration of the scores is an impractical technique in busy clinical settings and in this study (like similar recent studies); we used a common approach of numerical rating VAS that simply required patients to state whole numbers from 0 to 10. The protocol was approved by Shahid Beheshti Medical Ethics Department and the Review Committee for Reproductive Medicine. Patients were randomized to EMLA or control groups by a computer generated random allocation. We used block randomization without stratifying on confounder variables. A statistician generated the allocation sequence. Forty patients were randomized to the EMLA-treated group, and 40 to the placebo-control group. Before completing a questionnaire, participants were randomly allocated by specifying numbers on questionnaires by a secretary. The people who generated the allocation scheme were not involved in ascertaining eligibility, performing the procedure, and assessing the outcome. Both the HSG operator and the patient were blinded to the randomization. A researcher and HSG operator blinded to the randomization recorded the pain score specified by the patient at each stage of the procedure.

3.1. Cream Application and HSG

In patients allocated to the EMLA treated group, 5 grams of EMLA cream (Astra Zeneca) was applied tothe cervix by an applicator. In the control group, a placebo cream identical in color, smell and texture was used. The cream was placed on the uterine cervix using a vaginal speculum and a vaginal applicator 15 minutes before the procedure. The patient was placed in the lithotomy position on the radiology table. The procedure was performed under strictly sterile conditions. After insertion of the speculum, the cervix was localized and cleaned with povidone-iodine solution. Before cannulation, the cervix was grasped with a single-toothed tenaculum forceps at 12 o’clock position. After cannula placement and removal of the speculum, installation of water-soluble contrast material was started slowly (visipaque 320 mg/mL, each time 2-3 mL) and fluoroscopic images were obtained. At the end of the procedure and withdrawal of the instruments, the patient received observation care for an hour before discharge. In both groups, pain perception related to the HSG procedure was scored by VAS at five predefined steps: Step 1: Speculum application Step 2: Cervical instrumentation of the tenaculum and cannula Step3: At the end of uterine filling Step 4: Speculum and cannula withdrawal Step 5: Half an hour after the procedure

3.2. Statistical Analysis

The pain scores of the two groups were compared. In order to compare quantitative variables between the two groups, non-parametric Mann - Whitney U test was applied. SPSS15 software for Windows (SPSS Inc., Chicago, Il, USA) was used for statistical analysis and a P-value of 0.05 or less was considered statistically significant.

4. Results

Forty women were randomized to the EMLA-treated group, and 40 to the placebo-control group. There were no statistical differences in patients’ age (mean age of study group was 30.2 ± 6.7 and in the control group it was 29.1 ± 4.9). Patients’ self-reported VAS pain scores are presented in Table 1. There was no significant difference in the mean pain score between EMLA and placebo groups in pain perception during the entire procedure and 30 minutes after procedure.
Table 1.

The Mean Pain Score Between EMLA and Placebo Groups

The Mean Pain ScoreP Value
Speculum application 0.602
EMLA2.9 ± 2.6
Placebo3.3 ± 2.5
Cervical instrumentation of the tenaculum and cannula 0.321
EMLA5.1 ± 3.1
Placebo5.6 ± 2.3
At the end of uterine filling 0.716
EMLA6.6 ± 2.8
Placebo6.3 ± 2.7
Speculum and cannula withdrawal 0.466
EMLA2.6 ± 2.2
Placebo3 ± 2.9
30 minutes after procedure 0.596
EMLA1.7 ± 1.5
Placebo2 ± 2.6
In both groups, the most painful steps were step 3 (at the end of uterine filling) and step 2 (cervical instrumentation of the tenaculum and cannula). The detail and scores are illustrated in Figure 1.
Figure 1.

Flow diagram of analyzed data through phases of a parallel-randomized trial of two groups

Step 3 (at the end of uterine filling with contrast media) was significantly more painful than step2 (cervical instrumentation) in both groups (study group, P = 0.013; control group, P < 0.019). Step 3 was also significantly more painful than step 4 (speculum and cannula withdrawal, study group, P < 0.001; control group, P < 0.001). Cervical instrumentation (step 2) was significantly more painful than speculum application (step 1) in both groups (study group, P < 0.001; control group, P < 0.001). Step 5 (30 minutes after the procedure) was significantly less painful than step 4 (speculum and cannula withdrawal) in both groups (study group, P = 0.022; control group, P < 0.047). Step 5 was also significantly less painful than step 1 (speculum application) (study group, P < 0.003; control group, P < 0.005).

5. Discussion

HSG is a simple and cost effective investigation in assessing tubal patency. It is likely to have a key role in assessing tubal patency before undergoing infertility therapy, but the painful nature of HSG is the major reason the procedure has not gained wide acceptance between patients. The etiology of pain during the procedure is multifactorial and summarized as patient sensitivity to speculum application, cervical grasping, hydrostatic pressure of injection, stretched uterus, or peritoneal irritation (12). In this study, different pain levels were recorded during the entire procedure. Pain started with speculum application and increased with cervical instrumentation and reached the peak at the end of uterine filling. This study shows substantial decrease with speculum and cannula withdrawal. Pain perception was reduced to the lowest point, 30 minutes after the procedure. This pain pattern was the same in EMLA and placebo groups. In this study, there was no significant difference in efficacy between EMLA and placebo creams in pain perception through all steps of the procedure. There was no significant difference in long term pain perception half an hour after the HSG performance. Decreasing and increasing patterns of pain presentation during five predefined steps of HSG was the same in EMLA and placebo groups. There was no report of side effect and unexpected adverse events in the patients. These results are not in agreement with previous studies. One randomized controlled study on 80 women compared the effectiveness of EMLA versus placebo and reported evidence of significant reduction in pain during cervical instrumentation that was found the most painful step of the procedure in their study (1). They applied topical ELMA on the cervix by cervical cap 30 minutes before HSG. Topical lidocaine spray 10% is also reported as an effective analgesic during the HSG procedure (13). The limitation of this study could be due to the subjective nature of pain and influencing pain factors including differences in individual physical susceptibility, psychological factors, and socio-cultural differences to whom VAS is applied. The effects of psychological and socio-cultural differences are minimized by using randomization to assign the participants to the two groups. Psychological influences of infertility on the perception of pain were comparable as well as socio-cultural differences between the two groups. This study has not been designed to assess the association between pelvic pathology (pelvic adhesion and tubal occlusion) with more difficult and painful HSG performance. Further studies should consider the role of pelvic pathology in pain perception and also using intrauterine anesthetic combined with topical cervical anesthetic due to multifactorial pathogenesis of pain during HSG.
  13 in total

1.  Diagnostic quality and complications of hysterosalpingography: oil- versus water-soluble contrast media--a randomized prospective study.

Authors:  S Lindequist; P Justesen; C Larsen; F Rasmussen
Journal:  Radiology       Date:  1991-04       Impact factor: 11.105

2.  Some relationships between subjective measures of pain.

Authors:  J M Woodforde; H Merskey
Journal:  J Psychosom Res       Date:  1972-06       Impact factor: 3.006

3.  Pain associated with hysterosalpingography: Ethiodol versus Salpix media.

Authors:  D E Moore
Journal:  Fertil Steril       Date:  1982-11       Impact factor: 7.329

4.  Hysterosalpingography with a balloon catheter versus a metal cannula: a prospective, randomized, blinded comparative study.

Authors:  I Tur-Kaspa; D S Seidman; D Soriano; I Greenberg; J Dor; D Bider
Journal:  Hum Reprod       Date:  1998-01       Impact factor: 6.918

5.  Opioid analgesia for hysterosalpingography: controlled double-blind prospective trial with remifentanil and placebo.

Authors:  Mustafa Cengiz; Hasan Kafali; Hulya Artuc; Zeynep Baysal
Journal:  Gynecol Obstet Invest       Date:  2006-05-18       Impact factor: 2.031

6.  Lidocaine-prilocaine (EMLA) cream as analgesia for hysterosalpingography: a prospective, randomized, controlled, double blinded study.

Authors:  G Liberty; M Gal; T Halevy-Shalem; R Michaelson-Cohen; N Galoyan; J Hyman; T Eldar-Geva; E Vatashsky; E Margalioth
Journal:  Hum Reprod       Date:  2007-01-18       Impact factor: 6.918

7.  Pain relief in hysterosalpingography. A comparison of analgesics.

Authors:  C O Lorino; S G Prough; S Aksel; M Abuzeid; S E Alexander; R H Wiebe
Journal:  J Reprod Med       Date:  1990-05       Impact factor: 0.142

8.  Hysterosalpingography with a balloon catheter versus a cannula: evaluation of patient pain.

Authors:  M Varpula
Journal:  Radiology       Date:  1989-09       Impact factor: 11.105

Review 9.  Pain relief in hysterosalpingography.

Authors:  G Ahmad; J Duffy; A J S Watson
Journal:  Cochrane Database Syst Rev       Date:  2007-04-18

10.  Lidocaine 10% spray reduces pain during hysterosalpingography: a randomized controlled trial.

Authors:  Emre Karasahin; Ibrahim Alanbay; Ugur Keskin; Kazim Gezginc; Iskender Baser
Journal:  J Obstet Gynaecol Res       Date:  2009-04       Impact factor: 1.730

View more
  2 in total

Review 1.  Effectiveness of interventions for pain relief in hysterosalpingographyAnetwork meta-analysis and systematic review.

Authors:  Xin Guo; Zongjian Tan
Journal:  Pak J Med Sci       Date:  2017 Jul-Aug       Impact factor: 1.088

2.  Hysterosalpingogram findings among subfertile women undergoing assisted reproductive technology.

Authors:  Dania Al-Jaroudi; Abeer Abdullah Aldughayyim; Wadha Suliman Alshamry; Ahlam Saud Alrashidi; Ahmed A Bahnassy
Journal:  Int J Womens Health       Date:  2018-08-14
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.