Literature DB >> 25768327

Benign Solid Thyroid Nodules: US-guided High-Intensity Focused Ultrasound Ablation-Initial Clinical Outcomes.

Roussanka D Kovatcheva1, Jordan D Vlahov1, Julian I Stoinov1, Katja Zaletel1.   

Abstract

PURPOSE: To assess the short-term efficacy and safety of ultrasonographically (US)-guided high-intensity focused ultrasound (HIFU) ablation for treatment of benign solid thyroid nodules.
MATERIALS AND METHODS: This prospective study was approved by the institutional ethics committee, and written informed consent was acquired. HIFU ablation was performed in one session with US guidance and conscious sedation in 20 euthyroid patients (mean age, 44.5 years) with a benign solitary or dominant thyroid nodule. Thyroid nodule volume, US structure, and Doppler pattern were assessed at baseline, at 1 week, and at 1, 3, and 6 months after treatment. Adverse events associated with HIFU were evaluated. Statistical analysis was conducted by using repeated measures analysis of variance, the Student t test, χ(2) test, and correlation analysis.
RESULTS: The mean ± standard deviation nodule volume was 4.96 mL ± 2.79 at the start of the study. Nodule volume had decreased to 3.05 mL ± 1.96 at the 3-month follow-up examination (n = 20, P < .001), and reached 2.91 mL ± 2.43 by the 6-month follow-up examination (n = 16, P < .001). By then, the mean volume reduction was 48.7% ± 24.3 (P < .001). Isoechoic nodules showed greater reduction at 1 month than did hypoechoic nodules (31.6% ± 18.1 vs 16.4% ± 8.6, P = .053). Nodules with markedly increased blood flow showed smaller volume reduction at 3 months than did less-vascularized nodules (10.9% ± 14.5 vs 41.5% ± 20.3, P = .054). Minor transient complications (eg, subcutaneous edema, mild skin redness) were observed in two patients.
CONCLUSION: Early data suggest that US-guided HIFU ablation is an effective and safe procedure for treatment of benign solid thyroid nodules. Initial US echogenicity and vascularization influence the ablation outcome. (©) RSNA, 2015.

Entities:  

Mesh:

Year:  2015        PMID: 25768327     DOI: 10.1148/radiol.15141492

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  21 in total

1.  Significance of hyperechoic marks observed during high-intensity focused ultrasound (HIFU) ablation of benign thyroid nodules.

Authors:  Brian H H Lang; Yu-Cho Woo; Keith Wan-Hang Chiu
Journal:  Eur Radiol       Date:  2018-01-08       Impact factor: 5.315

2.  Effect of perithyroidal lignocaine infusion (PLI) to pain experienced during high-intensity focused ultrasound (HIFU) ablation of benign thyroid nodules.

Authors:  Brian H H Lang; Yu-Cho Woo; Keith Wan-Hang Chiu
Journal:  Eur Radiol       Date:  2019-03-27       Impact factor: 5.315

3.  High-intensity focused ultrasound (HIFU) for benign thyroid nodules: 2-year follow-up results.

Authors:  Pierpaolo Trimboli; Federico Pelloni; Fabiano Bini; Franco Marinozzi; Luca Giovanella
Journal:  Endocrine       Date:  2019-03-28       Impact factor: 3.633

Review 4.  Image-guided thermal ablation of benign thyroid nodules.

Authors:  Anna Pisani Mainini; Cristian Monaco; Lorenzo Carlo Pescatori; Chiara De Angelis; Francesco Sardanelli; Luca Maria Sconfienza; Giovanni Mauri
Journal:  J Ultrasound       Date:  2016-10-21

5.  Treatment of benign thyroid nodules by high intensity focused ultrasound (HIFU) at different acoustic powers: a study on in-silico phantom.

Authors:  Fabiano Bini; Pierpaolo Trimboli; Franco Marinozzi; Luca Giovanella
Journal:  Endocrine       Date:  2017-06-21       Impact factor: 3.633

6.  Two-year efficacy of single-session high-intensity focused ultrasound (HIFU) ablation of benign thyroid nodules.

Authors:  Brian H H Lang; Yu-Cho Woo; Keith Wan-Hang Chiu
Journal:  Eur Radiol       Date:  2018-06-19       Impact factor: 5.315

7.  Role of second high-intensity focused ultrasound (HIFU) treatment for unsatisfactory benign thyroid nodules after first treatment.

Authors:  Brian Hung-Hin Lang; Yu-Cho Woo; Keith Wan-Hang Chiu
Journal:  Eur Radiol       Date:  2018-08-07       Impact factor: 5.315

8.  Portable ultrasound-guided high-intensity focused ultrasound with functions for safe and rapid ablation: prospective clinical trial for uterine fibroids-short-term and long-term results.

Authors:  Jae Young Lee; Hyun Hoon Chung; Soo Yeon Kang; Eun-Joo Park; Dong Hyuk Park; Keonho Son; Joon Koo Han
Journal:  Eur Radiol       Date:  2019-11-08       Impact factor: 5.315

9.  High-intensity focused ultrasound (HIFU) therapy for benign thyroid nodules without anesthesia or sedation.

Authors:  Pierpaolo Trimboli; Fabiano Bini; Franco Marinozzi; Jung Hwan Baek; Luca Giovanella
Journal:  Endocrine       Date:  2018-02-16       Impact factor: 3.633

10.  Sequential high intensity focused ultrasound (HIFU) ablation in the treatment of benign multinodular goitre: an observational retrospective study.

Authors:  Brian H H Lang; Yu-Cho Woo; Keith Wan-Hang Chiu
Journal:  Eur Radiol       Date:  2018-03-19       Impact factor: 5.315

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.