Wear resistance of the biocompatible phospholipid polymer-grafted highly cross-linked polyethylene liner against larger femoral head.

Toru Moro1,2, Yoshio Takatori1,2, Masayuki Kyomoto1,3,4, Kazuhiko Ishihara3, Hiroshi Kawaguchi5, Masami Hashimoto6, Takeyuki Tanaka2, Hirofumi Oshima2, Sakae Tanaka2.   

Abstract

The use of larger femoral heads to prevent the dislocation of artificial hip joints has recently become more common. However, concerns about the subsequent use of thinner polyethylene liners and their effects on wear rate have arisen. Previously, we prepared and evaluated the biological and mechanical effects of a novel highly cross-linked polyethylene (CLPE) liner with a nanometer-scaled graft layer of poly(2-methacryloyloxyethyl phosphorylcholine) (PMPC). Our findings showed that the PMPC-grafted particles were biologically inert and caused no subsequent bone resorptive responses and that the PMPC-grafting markedly decreased wear in a hip joint simulator. However, the metal or ceramic femoral heads used in this previous study had a diameter of 26 mm. Here, we investigated the wear-resistance of the PMPC-grafted CLPE liner with a 40-mm femoral head during 10 × 10(6) cycles of loading in the hip joint simulator. The results provide preliminary evidence that the grafting markedly decreased gravimetric wear rate and the volume of wear particles, even when coupled with larger femoral heads. Thus, we believe the PMPC-grafting will prolong artificial hip joint longevity both by preventing aseptic loosening and by improving the stability of articular surface.
© 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

Entities:  

Keywords:  artificial hip joint; aseptic loosening; periprosthetic osteolysis; total hip arthroplasty

Mesh:

Substances:

Year:  2015        PMID: 25764495     DOI: 10.1002/jor.22868

Source DB:  PubMed          Journal:  J Orthop Res        ISSN: 0736-0266            Impact factor:   3.494


  2 in total

1.  Wear testing of a canine hip resurfacing implant that uses highly cross-linked polyethylene.

Authors:  Kevin J Warburton; John B Everingham; Jillian L Helms; Andrew J Kazanovicz; Katherine A Hollar; Jeff D Brourman; Steven M Fox; Trevor J Lujan
Journal:  J Orthop Res       Date:  2017-11-14       Impact factor: 3.494

Review 2.  Status of surface modification techniques for artificial hip implants.

Authors:  Subir Ghosh; Sylvester Abanteriba
Journal:  Sci Technol Adv Mater       Date:  2016-11-25       Impact factor: 8.090

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.