| Literature DB >> 25763130 |
Jae Young Park1, Gina Lim2, Ki Won Oh2, Dong Soo Ryu3, Seonghun Park4, Jong Chul Jeon1, Sang Hyeon Cheon1, Kyung Hyun Moon1, Sejun Park1, Sungchan Park1.
Abstract
PURPOSE: Anogential distance (AGD) and the 2:4 digit length ratio appear to provide a reliable guide to fetal androgen exposure. We intended to investigate the current status of penile size and the relationship between penile length and AGD or digit length according to birth weight in Korean newborn infants.Entities:
Keywords: Anthropometry; Newborn infants; Penis
Mesh:
Year: 2015 PMID: 25763130 PMCID: PMC4355437 DOI: 10.4111/kju.2015.56.3.248
Source DB: PubMed Journal: Korean J Urol ISSN: 2005-6737
Fig. 1Measurement of anogenital distance (AGD) and 2:4 digit lengths. (A) AGD has been measured in three ways (AGD1, AGD2, AGD3), AGD3 appears to be the most reliable and repeatable measurement. (B) Digit lengths is measured form the basal crease to the tip on the ventral surface of the hand at the point midway across a line perpendicular to the base using rulers.
Changes in stretched penile length and anthropometric data compared with a previous study conducted in 1987
| Variable | Present data (n=24) | 1987 Data (n=49) | p-value |
|---|---|---|---|
| Penile size (cm) | 3.3±0.2 | 3.3±0.5 | 0.445 |
| Testis size (mL ) | 1.1±0.4 | 1.2±0.2 | 0.248 |
| Height (cm) | 49.8±1.9 | 52.5±2.5 | <0.001 |
| Weight (kg) | 3.2±0.5 | 3.3±0.4 | 0.393 |
Values are presented as mean±standard deviation.
Modified from Chung KH, et al. Korean J Urol 1987;28:255-8 [8].
Differences in penile length, digit lengths, anogenital distances, and anthropometric data according to birth weight
| Variable | Normal birth weight group (n=24) | Low birth weight group (n=31) | p-value |
|---|---|---|---|
| Penile size (cm) | 3.3±0.2 | 2.9±0.4 | <0.001 |
| Testis size (mL ) | 1.1±0.4 | 0.8±0.4 | <0.001 |
| Height (cm) | 49.8±1.9 | 44.1±2.9 | <0.001 |
| Weight (kg) | 3.2±0.5 | 2.1±0.4 | 0.006 |
| SPL/height (×10-2) | 6.9±0.5 | 6.3±0.4 | <0.001 |
| Digit 2 (cm) | 2.6±0.2 | 2.2±0.2 | <0.001 |
| Digit 4 (cm) | 2.8±0.3 | 2.4±0.2 | <0.001 |
| Digit 2/4 ratio | 0.92±0.03 | 0.93±0.05 | 0.419 |
| AGD 1a (cm) | 4.2±0.3 | 3.6±0.4 | <0.001 |
| AGD 2b (cm) | 3.5±0.3 | 3.1±0.3 | <0.001 |
| AGD 3c (cm) | 2.3±0.2 | 2.0±0.2 | <0.001 |
| AGD 3/height (×10-2) | 4.8± 0.5 | 4.6±0.4 | 0.056 |
| AGD 1-3 (cm) | 1.8±0.3 | 1.6±0.3 | <0.001 |
| AGD 1-2 (cm) | 0.6±0.1 | 0.5±0.1 | 0.003 |
| AGD (1-2)/(1-3) ratio | 0.35±0.05 | 0.34±0.05 | 0.478 |
Values are presented as mean±standard deviation.
SPL, stretched penile length; AGD, anogenital distance.
a:AGD1 was the distance measured from the anterior aspect of the penis to the anal verge. b:AGD2 was the distance measured from the posterior aspect of the penis to the anal verge. c:AGD3 was the distance measured from the posterior aspect of the scrotum to the anal verge.