Literature DB >> 25751863

3-D Stent Detection in Intravascular OCT Using a Bayesian Network and Graph Search.

Michael W Jenkins, George C Linderman, Hiram G Bezerra, Yusuke Fujino, Marco A Costa, David L Wilson, Andrew M Rollins.   

Abstract

Worldwide, many hundreds of thousands of stents are implanted each year to revascularize occlusions in coronary arteries. Intravascular optical coherence tomography is an important emerging imaging technique, which has the resolution and contrast necessary to quantitatively analyze stent deployment and tissue coverage following stent implantation. Automation is needed, as current, it takes up to 16 h to manually analyze hundreds of images and thousands of stent struts from a single pullback. For automated strut detection, we used image formation physics and machine learning via a Bayesian network, and 3-D knowledge of stent structure via graph search. Graph search was done on en face projections using minimum spanning tree algorithms. Depths of all struts in a pullback were simultaneously determined using graph cut. To assess the method, we employed the largest validation data set used so far, involving more than 8000 clinical images from 103 pullbacks from 72 patients. Automated strut detection achieved a 0.91±0.04 recall, and 0.84±0.08 precision. Performance was robust in images of varying quality. This method can improve the workflow for analysis of stent clinical trial data, and can potentially be used in the clinic to facilitate real-time stent analysis and visualization, aiding stent implantation.

Entities:  

Year:  2015        PMID: 25751863      PMCID: PMC4547908          DOI: 10.1109/TMI.2015.2405341

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  24 in total

1.  The perceptron: a probabilistic model for information storage and organization in the brain.

Authors:  F ROSENBLATT
Journal:  Psychol Rev       Date:  1958-11       Impact factor: 8.934

2.  Automatic vessel lumen segmentation and stent strut detection in intravascular optical coherence tomography.

Authors:  Stavros Tsantis; George C Kagadis; Konstantinos Katsanos; Dimitris Karnabatidis; George Bourantas; George C Nikiforidis
Journal:  Med Phys       Date:  2012-01       Impact factor: 4.071

3.  Optimal surface segmentation in volumetric images--a graph-theoretic approach.

Authors:  Kang Li; Xiaodong Wu; Danny Z Chen; Milan Sonka
Journal:  IEEE Trans Pattern Anal Mach Intell       Date:  2006-01       Impact factor: 6.226

Review 4.  Stent thrombosis late after implantation of first-generation drug-eluting stents: a cause for concern.

Authors:  Edoardo Camenzind; P Gabriel Steg; William Wijns
Journal:  Circulation       Date:  2007-03-07       Impact factor: 29.690

5.  Automatic quantitative analysis of in-stent restenosis using FD-OCT in vivo intra-arterial imaging.

Authors:  Kostas Mandelias; Stavros Tsantis; Stavros Spiliopoulos; Paraskevi F Katsakiori; Dimitris Karnabatidis; George C Nikiforidis; George C Kagadis
Journal:  Med Phys       Date:  2013-06       Impact factor: 4.071

6.  3D assessment of stent cell size and side branch access in intravascular optical coherence tomographic pullback runs.

Authors:  Ancong Wang; Jeroen Eggermont; Niels Dekker; Patrick J H de Koning; Johan H C Reiber; Jouke Dijkstra
Journal:  Comput Med Imaging Graph       Date:  2013-09-07       Impact factor: 4.790

7.  Automatic segmentation of the wire frame of stent grafts from CT data.

Authors:  Almar Klein; J Adam van der Vliet; Luuk J Oostveen; Yvonne Hoogeveen; Leo J Schultze Kool; W Klaas Jan Renema; Cornelis H Slump
Journal:  Med Image Anal       Date:  2011-05-31       Impact factor: 8.545

8.  Everolimus-eluting versus paclitaxel-eluting stents in coronary artery disease.

Authors:  Gregg W Stone; Ali Rizvi; William Newman; Kourosh Mastali; John C Wang; Ronald Caputo; Julie Doostzadeh; Sherry Cao; Charles A Simonton; Krishnankutty Sudhir; Alexandra J Lansky; Donald E Cutlip; Dean J Kereiakes
Journal:  N Engl J Med       Date:  2010-05-06       Impact factor: 91.245

Review 9.  Intracoronary optical coherence tomography: a comprehensive review clinical and research applications.

Authors:  Hiram G Bezerra; Marco A Costa; Giulio Guagliumi; Andrew M Rollins; Daniel I Simon
Journal:  JACC Cardiovasc Interv       Date:  2009-11       Impact factor: 11.195

10.  Automatic stent detection in intravascular OCT images using bagged decision trees.

Authors:  Hong Lu; Madhusudhana Gargesha; Zhao Wang; Daniel Chamie; Guilherme F Attizzani; Tomoaki Kanaya; Soumya Ray; Marco A Costa; Andrew M Rollins; Hiram G Bezerra; David L Wilson
Journal:  Biomed Opt Express       Date:  2012-10-15       Impact factor: 3.732

View more
  10 in total

1.  Circumferential optical coherence tomography angiography imaging of the swine esophagus using a micromotor balloon catheter.

Authors:  Hsiang-Chieh Lee; Osman Oguz Ahsen; Kaicheng Liang; Zhao Wang; Cody Cleveland; Lucas Booth; Benjamin Potsaid; Vijaysekhar Jayaraman; Alex E Cable; Hiroshi Mashimo; Robert Langer; Giovanni Traverso; James G Fujimoto
Journal:  Biomed Opt Express       Date:  2016-07-05       Impact factor: 3.732

2.  Establishment of an Automated Algorithm Utilizing Optical Coherence Tomography and Micro-Computed Tomography Imaging to Reconstruct the 3-D Deformed Stent Geometry.

Authors:  Mark R Elliott; Dan Kim; David S Molony; Liam Morris; Habib Samady; Sarang Joshi; Lucas H Timmins
Journal:  IEEE Trans Med Imaging       Date:  2019-03       Impact factor: 10.048

3.  Stent detection with very thick tissue coverage in intravascular OCT.

Authors:  Guangqian Yang; Emile Mehanna; Chao Li; Hongyi Zhu; Chong He; Fang Lu; Ke Zhao; Yubin Gong; Zhao Wang
Journal:  Biomed Opt Express       Date:  2021-11-11       Impact factor: 3.732

4.  Cascaded learning in intravascular ultrasound: coronary stent delineation in manual pullbacks.

Authors:  Tobias Wissel; Katharina A Riedl; Klaus Schaefers; Hannes Nickisch; Fabian J Brunner; Nikolas D Schnellbaecher; Stefan Blankenberg; Moritz Seiffert; Michael Grass
Journal:  J Med Imaging (Bellingham)       Date:  2022-03-28

5.  Quantitative analysis of the side-branch orifice after bifurcation stenting using en-face processing of OCT images: a comparison between Xience V and Resolute Integrity stents.

Authors:  Yoshiyasu Minami; Zhao Wang; Aaron D Aguirre; Stephen Lee; Shiro Uemura; Tsunenari Soeda; Rocco Vergallo; Owen C Raffel; Peter Barlis; Tomonori Itoh; Hang Lee; James Fujimoto; Ik-Kyung Jang
Journal:  Coron Artery Dis       Date:  2016-01       Impact factor: 1.439

6.  Automatic Lumen Segmentation in Intravascular Optical Coherence Tomography Images Using Level Set.

Authors:  Yihui Cao; Kang Cheng; Xianjing Qin; Qinye Yin; Jianan Li; Rui Zhu; Wei Zhao
Journal:  Comput Math Methods Med       Date:  2017-02-07       Impact factor: 2.238

Review 7.  Patient-Specific Modeling of Stented Coronary Arteries Reconstructed from Optical Coherence Tomography: Towards a Widespread Clinical Use of Fluid Dynamics Analyses.

Authors:  Claudio Chiastra; Susanna Migliori; Francesco Burzotta; Gabriele Dubini; Francesco Migliavacca
Journal:  J Cardiovasc Transl Res       Date:  2017-12-27       Impact factor: 4.132

8.  Application and Evaluation of Highly Automated Software for Comprehensive Stent Analysis in Intravascular Optical Coherence Tomography.

Authors:  Hong Lu; Juhwan Lee; Martin Jakl; Zhao Wang; Pavel Cervinka; Hiram G Bezerra; David L Wilson
Journal:  Sci Rep       Date:  2020-02-07       Impact factor: 4.379

9.  Automatic Annotation of Retinal Layers in Optical Coherence Tomography Images.

Authors:  Bashir Isa Dodo; Yongmin Li; Khalid Eltayef; Xiaohui Liu
Journal:  J Med Syst       Date:  2019-11-13       Impact factor: 4.460

10.  Automatic Detection of Coronary Metallic Stent Struts Based on YOLOv3 and R-FCN.

Authors:  Xiaolu Jiang; Yanqiu Zeng; Shixiao Xiao; Shaojie He; Caizhi Ye; Yu Qi; Jiangsheng Zhao; Dezhi Wei; Muhua Hu; Fei Chen
Journal:  Comput Math Methods Med       Date:  2020-09-01       Impact factor: 2.238

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.