PURPOSE: This study evaluated mid-term results of anterior cruciate ligament (ACL) reconstruction using the PINN-ACL CrossPin system that allowed for short graft fixation. MATERIALS AND METHODS: Forty-three patients underwent single-bundle ACL reconstruction with a 4-strand semitendinosus tendon graft using the PINN-ACL CrossPin system. Femoral fixation was done using the PINN-ACL CrossPin system, and the tibial side was fixed with post-tie and a bioabsorbable interference screw. The mean follow-up period was 50 months. Evaluation was done using the Lachman test, pivot-shift test, International Knee Documentation Committee (IKDC) score and grade. Anterior displacement was assessed. RESULTS: There was improvement in the Lachman test and pivot-shift test at final follow-up, form grade II (n=40) or III (n=3) to grade I (n=3) or 0 (n=40) and from grade I (n=20) or II (n=10) to grade I (n=8) or 0 (n=22), respectively. The mean IKDC score was 88.7, and grade A and B were 93.0% at final follow-up. Side-to-side difference was improved from 6.7 mm to 2.1 mm at final follow-up. Complications occurred in 3 patients, a re-ruptured due to trauma at 2 years after surgery and a deep infection and a superficial infection. CONCLUSIONS: The mid-term follow-up results of ACL reconstruction with the PINN-ACL CrossPin system were satisfactory. The PINN-ACL CrossPin can be considered as a useful instrument for short graft fixation.
PURPOSE: This study evaluated mid-term results of anterior cruciate ligament (ACL) reconstruction using the PINN-ACL CrossPin system that allowed for short graft fixation. MATERIALS AND METHODS: Forty-three patients underwent single-bundle ACL reconstruction with a 4-strand semitendinosus tendon graft using the PINN-ACL CrossPin system. Femoral fixation was done using the PINN-ACL CrossPin system, and the tibial side was fixed with post-tie and a bioabsorbable interference screw. The mean follow-up period was 50 months. Evaluation was done using the Lachman test, pivot-shift test, International Knee Documentation Committee (IKDC) score and grade. Anterior displacement was assessed. RESULTS: There was improvement in the Lachman test and pivot-shift test at final follow-up, form grade II (n=40) or III (n=3) to grade I (n=3) or 0 (n=40) and from grade I (n=20) or II (n=10) to grade I (n=8) or 0 (n=22), respectively. The mean IKDC score was 88.7, and grade A and B were 93.0% at final follow-up. Side-to-side difference was improved from 6.7 mm to 2.1 mm at final follow-up. Complications occurred in 3 patients, a re-ruptured due to trauma at 2 years after surgery and a deep infection and a superficial infection. CONCLUSIONS: The mid-term follow-up results of ACL reconstruction with the PINN-ACL CrossPin system were satisfactory. The PINN-ACL CrossPin can be considered as a useful instrument for short graft fixation.
Authors: Thore Zantop; Andre Weimann; Markus Rümmler; Joachim Hassenpflug; Wolf Petersen Journal: Am J Sports Med Date: 2004 Apr-May Impact factor: 6.202