Literature DB >> 25747827

Short communication: Comparison of estrus characteristics in Holstein heifers by 2 activity monitoring systems.

B F Silper1, A M L Madureira1, M Kaur1, T A Burnett1, R L A Cerri2.   

Abstract

Two activity monitoring systems-Heatime (SCR Engineers Ltd., Netanya, Israel) and IceTag (IceRobotics Ltd., Edinburgh, UK)-were compared on their ability to detect and quantify estrus expression. Holstein heifers (n=57) were fitted with Heatime (HT) and IceTag (IT) sensors from 12 mo of age until confirmation of pregnancy. Upon detection of high activity by HT, ovaries were scanned by ultrasound, a blood sample was collected for analysis of plasma estradiol, and signs of estrus (clear vaginal mucus, uterine muscle tone, visual mounting activity, standing to be mounted, or rump showing signs of repeated acceptance of mounts) were recorded. Because only estrus episodes detected by HT (n=111) were further evaluated, only the positive predictive value was measured. Heifers were housed in groups of 24 in a freestall pen. Data were analyzed using Proc CORR and GLM of SAS (SAS Institute Inc., Cary, NC). The positive predictive value was 84.7% (94/111) for HT and 98.7% (74/75) for IT. Estrus duration was recorded by HT as 14.3±4.1h [mean ± standard deviation (SD)] and by IT as 15.0±4.0h; duration measurements were correlated (r=0.60). The mean duration difference was 0.74±3.52h. Recordings of onset and end of estrus by IT were 3.5±4.3h and 2.9±4.9h earlier than those by HT. The overlap in duration was 9h. Measurements of estrus intensity were correlated (r=0.63). Peak activity was 77.3±19.5 index value (approximately 7.7 SD from basal activity) on HT. The relative increase in activity measured by IT was 360±170% baseline value. Measurements of intensity and duration from HT were correlated (r=0.64) but those from IT were not (r=0.13). Plasma estradiol concentration (11.2±4.6pg/mL) was not correlated with preovulatory follicle diameter or with duration or intensity of estrus. Diameter of preovulatory follicle (15.7±2.6mm) had no correlation with duration of estrus and was only weakly correlated with intensity measured by either system. Baseline steps/hour was negatively correlated with intensity from both sensors (r=-0.37 and -0.70 for HT and IT). Estrus episodes accompanied by 2 or 3 of the monitored signs of estrus had greater intensity and duration on HT but not on IT. Preovulatory follicle diameter and plasma estradiol concentration did not influence occurrence of estrus signs. Results indicate that both systems identified estrus precisely, with correlated characterization and similar timing. In contrast, relationships with plasma estradiol concentration and signs of estrus require further investigation.
Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  accelerometer; dairy; estrus detection; pedometer

Mesh:

Substances:

Year:  2015        PMID: 25747827     DOI: 10.3168/jds.2014-9185

Source DB:  PubMed          Journal:  J Dairy Sci        ISSN: 0022-0302            Impact factor:   4.034


  2 in total

1.  Impacts of estrus expression and intensity during a timed-AI protocol on variables associated with fertility and pregnancy success in Bos indicus-influenced beef cows.

Authors:  A D Rodrigues; R F Cooke; R S Cipriano; L G T Silva; R L A Cerri; L H Cruppe; M Meneghetti; K G Pohler; J L M Vasconcelos
Journal:  J Anim Sci       Date:  2018-02-15       Impact factor: 3.159

2.  The Detection of Bovine Estrus by Lactoferrin Monoclonal Antibody.

Authors:  Jihwan Lee; Suhyun Lee; Younbae Park; Seokhyun Lee; Seungmin Ha; Manhye Han; Gulwon Jang; Myunghum Park; Kyungwoon Kim; Hakjae Chung
Journal:  Animals (Basel)       Date:  2021-05-28       Impact factor: 2.752

  2 in total