Literature DB >> 25738177

Immediate loading of fixed cross-arch prostheses supported by flapless-placed supershort or long implants: 1-year results from a randomised controlled trial.

Gioacchino Cannizzaro, Pietro Felice, Jacopo Buti, Michele Leone, Vittorio Ferri, Marco Esposito.   

Abstract

PURPOSE: To compare the outcome of cross-arch prostheses supported either by supershort (5 mm) or long (11.5 mm) implants, placed flapless and immediately restored with metal-resin screw-retained cross-arch prostheses.
MATERIALS AND METHODS: Thirty patients with edentulous (or to be rendered edentulous) mandibles and 30 with edentulous maxillas, who had sufficient bone to allow the placement of four and six implants respectively, which were at least 11.5 mm-long, were randomised according to a parallel group design into 2 equal groups, where they received either 5 mm or 11.5 mm-long implants at one centre. Implants with a diameter of 5 mm, were to be placed flapless with an insertion torque of at least 50 Ncm. Mandibles received four implants between the mental foramina. Implants were to be immediately loaded with metal-resin-definitive prostheses on the same day of implant placement. Patients were followed up to 1 year after loading and the outcome measures were: prosthesis and implant failures, complications, and peri-implant marginal bone level changes.
RESULTS: No patients dropped-out. Two prostheses were remade, one on short maxillary implants and one on long mandibular implants. Two 5 mm maxillary implants which did not achieve 50 Ncm torque in soft bone of one patient, but were immediately loaded anyway, failed after 3 weeks compared to one mandibular 11.5 mm-long implant that failed after 60 days. Two complications occurred in each group. There were no statistically significant differences for prosthesis failures, implant failures and complications. Patients with mandibular short implants lost on average 0.08 mm of peri-implant bone at 1 year and patients with long mandibular implants lost 0.51 mm. Patients with short maxillary implants lost on average 0.15 mm of peri-implant bone at 1 year and patients with long maxillary implants lost 0.62 mm. Short implants showed less bone loss when compared to long implants and the differences up to 1 year were statistically significant both in maxillae (mean difference = 0.48 mm, 95% CI 0.22 to 0.73, P = 0.0011) and in mandibles (mean difference = 0.44 mm, 95% CI 0.21 to 0.66, P = 0.0009).
CONCLUSIONS: Flapless-placed 5 mm-long implants achieved similar results as 11.5 mm-long implants when supporting immediately loaded cross-arch prostheses both in maxillae and mandibles up to 1 year after loading. These preliminary results must be confirmed by other trials, and 5- to 10-year post-loading data is necessary before making reliable recommendations.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25738177

Source DB:  PubMed          Journal:  Eur J Oral Implantol        ISSN: 1756-2406            Impact factor:   3.123


  7 in total

Review 1.  Short versus Longer Implants in Sites without the Need for Bone Augmentation: A Systematic Review and Meta-Analysis of Randomized Controlled Trials.

Authors:  Luigi Guida; Eriberto Bressan; Gennaro Cecoro; Armando Davide Volpe; Massimo Del Fabbro; Marco Annunziata
Journal:  Materials (Basel)       Date:  2022-04-26       Impact factor: 3.748

2.  "All on short" prosthetic-implant supported rehabilitations.

Authors:  G Falisi; S Bernardi; C Rastelli; D Pietropaoli; F DE Angelis; M Frascaria; C DI Paolo
Journal:  Oral Implantol (Rome)       Date:  2017-01-21

3.  Immediate Loading of Short Implants in Posterior Maxillae: Case Series.

Authors:  Eduardo Anitua
Journal:  Acta Stomatol Croat       Date:  2017-06

Review 4.  Marginal bone loss 1 year after implantation: a systematic review for fixed and removable restorations.

Authors:  Jennifer Zimmermann; Melanie Sommer; Leticia Grize; Stefan Stubinger
Journal:  Clin Cosmet Investig Dent       Date:  2019-07-16

5.  A meta-analysis indicating extra-short implants (≤ 6 mm) as an alternative to longer implants (≥ 8 mm) with bone augmentation.

Authors:  Xiaoran Yu; Ruogu Xu; Zhengchuan Zhang; Yang Yang; Feilong Deng
Journal:  Sci Rep       Date:  2021-04-14       Impact factor: 4.379

Review 6.  Clinical Comparation of Extra-Short (4 mm) and Long (>8 mm) Dental Implants Placed in Mandibular Bone: A Systematic Review and Metanalysis.

Authors:  Vittorio Moraschini; Carlos Fernando de Almeida Barros Mourão; Pietro Montemezzi; Ingrid Chaves Cavalcante Kischinhevsky; Daniel Costa Ferreira de Almeida; Kayvon Javid; Jamil Awad Shibli; José Mauro Granjeiro; Monica Diuana Calasans-Maia
Journal:  Healthcare (Basel)       Date:  2021-03-12

Review 7.  Dental Implants Inserted in Fresh Extraction Sockets versus Healed Sites: A Systematic Review and Meta-Analysis.

Authors:  Adam Ibrahim; Bruno Ramos Chrcanovic
Journal:  Materials (Basel)       Date:  2021-12-20       Impact factor: 3.623

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.