Literature DB >> 25738082

A qualitative analysis to compare the effects of surface machining of conventional denture base resin and two soft liners: a scanning electron microscopic study.

Santoshi V Kumari1, M Taruna2, B Chittaranjan3, Sushendhar M Reddy4, Kranti Kiran E Reddy5, Ganesh Kulkarni6.   

Abstract

INTRODUCTION: The denture base acrylic resins require adjustments for various reasons. During this process there is an alteration in the surface characteristics of the denture base. Rough surfaces promote the bacterial adhesion and plaque accumulation; therefore it is important to know the character of the surface left by instrumentation on denture base materials. This study evaluated the surface characteristics of the machined surfaces of heat-cured acrylic denture base resin, GC supersoft and Permasoft softliners.
MATERIALS AND METHODS: Thirty 15×15×1.5mm acrylic resin specimens were fabricated with each of three acrylic resins: Lucitone 199 denture base resin (Group I), GC supersoft (Group II) and Permasoft (Group III) softliners. They were further divided into three sub Groups A, B and C, in which Sub Group A was control group that is smooth produced against the glass. Sub Group B was produced by machining with the tungsten carbide bur and Sub group C is machined with the stone bur. Each surface was evaluated by a Scanning electron microscope and data were analyzed by analysis of variance followed by Tukey's HSD test.
RESULTS: Stone bur produced smoother surface (Ra 3.6681μm± 0.254) on Lucitone199 than the tungsten carbide bur (Ra 5.3881μm ± 0.3373). Carbide bur produced a smoother surface on the GC super soft (Ra 1.617097μm ± 0.191767) and Permasoft softliners (Ra 2.237419μm ± 0.354259). Whereas stone bur produced rougher surface on GC supersoft(Ra 2.6μm) and Permasoft (Ra 4.184839μm ± 0.409869) softliners.
CONCLUSION: The present study shows each type of rotary instrument produces its own characteristic surface on each type of denture base materials and that care is needed when selecting the most appropriate instrument to adjust denture base materials. These results can have a significant clinical implication. While using Lucitone 199 stone bur can be used for chair side adjustments. Tungsten carbide bur can be used for GC supersoft and Permasoft softliners to achieve smoother surface.

Entities:  

Keywords:  Acrylic denture base resin; Machining; Soft-liners; Surface roughness

Year:  2015        PMID: 25738082      PMCID: PMC4347173          DOI: 10.7860/JCDR/2015/11310.5474

Source DB:  PubMed          Journal:  J Clin Diagn Res        ISSN: 0973-709X


  11 in total

Review 1.  Soft liners.

Authors:  Lily T Garcia; John D Jones
Journal:  Dent Clin North Am       Date:  2004-07

2.  Effects of polishing techniques on the surface roughness of acrylic denture base resins.

Authors:  Milan Kuhar; Nenad Funduk
Journal:  J Prosthet Dent       Date:  2005-01       Impact factor: 3.426

3.  Surface roughness of auto polymerized acrylic resin according to different manipulation and polishing methods: an in situ evaluation.

Authors:  Tatiana Siqueira Gonçalves; Ana Maria Spohr; Rodrigo Matos de Souza; Luciane Macedo de Menezes
Journal:  Angle Orthod       Date:  2008-09       Impact factor: 2.079

4.  Effects of chemical disinfectants on the surface characteristics and color of denture resins.

Authors:  T Ma; G H Johnson; G E Gordon
Journal:  J Prosthet Dent       Date:  1997-02       Impact factor: 3.426

5.  The effects of surface machining on heat cured acrylic resin and two soft denture base materials: a scanning electron microscope and confocal microscope evaluation.

Authors:  D R Radford; T F Watson; J D Walter; S J Challacombe
Journal:  J Prosthet Dent       Date:  1997-08       Impact factor: 3.426

Review 6.  The clinical meaning of the surface roughness and the surface free energy of intra-oral hard substrata on the microbiology of the supra- and subgingival plaque: results of in vitro and in vivo experiments.

Authors:  M Quirynen
Journal:  J Dent       Date:  1994       Impact factor: 4.379

7.  Retention of Candida albicans on acrylic resin and silicone of different surface topography.

Authors:  J Verran; C J Maryan
Journal:  J Prosthet Dent       Date:  1997-05       Impact factor: 3.426

8.  Effect of finishing and polishing procedures on the gap width between a denture base resin and two long-term, resilient denture liners.

Authors:  Igor J Pesun; James Hodges; Juey H Lai
Journal:  J Prosthet Dent       Date:  2002-03       Impact factor: 3.426

9.  Chairside polishing of heat-cured acrylic resin: an SEM and EDA study.

Authors:  E Fionnuala O'Donnell; David R Radford; Gary F Sinclair; Robert K F Clark
Journal:  Int J Prosthodont       Date:  2003 May-Jun       Impact factor: 1.681

10.  Influence of incorporation of fluoroalkyl methacrylates on roughness and flexural strength of a denture base acrylic resin.

Authors:  Tatiana Ramirez Cunha; Romulo Rocha Regis; Marília Rodrigues Bonatti; Raphael Freitas de Souza
Journal:  J Appl Oral Sci       Date:  2009 Mar-Apr       Impact factor: 2.698

View more