Literature DB >> 25735933

Proximal occlusion versus distal filter for cerebral protection during carotid stenting: updated meta-analysis of randomised and observational MRI studies.

Salvatore Cassese1, Gjin Ndrepepa, Lamin A King, Mateja Nerad, Heribert Schunkert, Adnan Kastrati, Ilka Ott, Massimiliano Fusaro.   

Abstract

AIMS: Proximal occlusion (PO) and distal filter (DF) serve for cerebral embolic protection during carotid artery stenting (CAS). New cerebral lesions at diffusion-weighted magnetic resonance imaging (DW-MRI) represent a surrogate endpoint for embolisation, though their clinical impact is controversial. We performed a meta-analysis of randomised and observational DW-MRI studies comparing PO and DF during CAS. METHODS AND
RESULTS: We searched electronic scientific databases. The primary endpoint was the incidence of new cerebral lesions at DW-MRI; secondary endpoints were the incidence of new ipsilateral and new contralateral cerebral lesions at DW-MRI and death/cerebrovascular events (CVE). A total of 392 patients (seven studies) received CAS. At DW-MRI after 48 hours 178 patients (48.3%) presented new cerebral lesions. The use of PO versus DF reduced neither the risk of new cerebral lesions (OR [95% confidence interval] 0.65 [0.28-1.52], p=0.32) nor the risk of death/CVE (0.59 [0.22-1.60], p=0.30). Diabetes, baseline stenosis and symptoms significantly modified the risk estimates for new cerebral lesions.
CONCLUSIONS: In this meta-analysis, one half of patients receiving protected CAS developed new embolic cerebral lesions at DW-MRI, although the overwhelming majority were asymptomatic. Cerebral protection with PO versus DF neither reduced cerebral embolisation nor impacted on clinical outcomes.

Entities:  

Mesh:

Year:  2015        PMID: 25735933     DOI: 10.4244/EIJY15M03_01

Source DB:  PubMed          Journal:  EuroIntervention        ISSN: 1774-024X            Impact factor:   6.534


  5 in total

1.  Editorial comment: sandwich carotid stenting: too much of a good thing?

Authors:  Giuseppe Biondi-Zoccai; Enrico Romagnoli; Giacomo Frati; Francesco Versaci
Journal:  Eur Radiol       Date:  2018-10-30       Impact factor: 5.315

Review 2.  Carotid Stenting in Neuroradiology : A Short Journey from the Past to Current Debates.

Authors:  Joachim Berkefeld; Marlies Wagner; Richard du Mesnil
Journal:  Clin Neuroradiol       Date:  2017-06-16       Impact factor: 3.649

3.  Predictors of antegrade flow at internal carotid artery during carotid artery stenting with proximal protection.

Authors:  Kei Harada; Kosuke Kakumoto; Shogo Oshikata; Kozo Fukuyama
Journal:  Acta Neurochir (Wien)       Date:  2018-02-16       Impact factor: 2.216

Review 4.  Transcervical access, reversal of flow and mesh-covered stents: New options in the armamentarium of carotid artery stenting.

Authors:  Kosmas I Paraskevas; Frank J Veith
Journal:  World J Cardiol       Date:  2017-05-26

5.  Low Common Carotid Artery Systolic Occlusion Pressure and Symptomatic Carotid Artery Stenosis Are Associated with Development of Neurologic Intolerance during Proximal Protected Carotid Artery Stenting.

Authors:  Hee Jin Kwon; Jae Hyeong Park; Jae Hwan Lee; Hye Seon Jeong; Hee Jung Song; Jei Kim; Mijoo Kim; In Sun Kwon; In Whan Seong
Journal:  Korean Circ J       Date:  2018-03       Impact factor: 3.243

  5 in total