Literature DB >> 25735263

Monitoring minute ventilation versus respiratory rate to measure the adequacy of ventilation in patients undergoing upper endoscopic procedures.

Katherine Holley1, C Marshall MacNabb2, Paige Georgiadis3, Hayk Minasyan4, Anurag Shukla5, Donald Mathews6.   

Abstract

Endoscopic procedures performed under conscious sedation require careful monitoring of respiratory status to prevent adverse outcomes. This study utilizes a non-invasive respiratory volume monitor (RVM) that provides continuous real-time measurements of minute ventilation (MV), tidal volume and respiratory rate (RR) to assess the adequacy of ventilation during endoscopy. Digital respiratory traces were collected from 51 patients undergoing upper endoscopy with propofol sedation using an impedance-based RVM. Baseline MV for each patient was derived from a 30 s period of quiet breathing prior to sedation (MVBASELINE). Capnography data were also collected. Because RR from capnography was frequently unavailable, the RVM RR's were used for analysis. RR rate values were compared the MV measurements and sensitivity and specificity of RR to predict inadequate ventilation (MV <40 % MVBASELINE) were calculated. Initial analysis revealed that there is a weak correlation between an MV measurement and its corresponding RR measurement (r = 0.05). If MV is an actual indictor of respiratory performance, using RR as a proxy is grossly inadequate. Simulating a variety of RR alarm conditions [4-8 breaths/min (bpm)] showed that a substantial fraction of low MV measurements (MV <40 % MVBASELINE) went undetected (at 8 bpm, >70 % low MV measurements were missed; at 6 bpm, >82 % were missed; and at 4 bpm, >90 % were missed). A cut-off of 6 bpm had a sensitivity of only 18.2 %; while <40 % of all RR alarms would have coincided with a low MV (39.4 % PPV). Low RR measurements alone do not reflect episodes of low MV and are not sufficient for accurate assessment of respiratory status. RVM provides a new way to collect MV measurements which provide more comprehensive data than RR alone. Further work is ongoing to evaluate the use of MV data during procedural sedation.

Entities:  

Keywords:  Accuracy; Endoscopy; Minute ventilation; Respiratory rate

Mesh:

Year:  2015        PMID: 25735263     DOI: 10.1007/s10877-015-9674-y

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  17 in total

1.  Practice guidelines for sedation and analgesia by non-anesthesiologists.

Authors: 
Journal:  Anesthesiology       Date:  2002-04       Impact factor: 7.892

2.  Has oxygen administration delayed appropriate respiratory care? Fallacies regarding oxygen therapy.

Authors:  John B Downs
Journal:  Respir Care       Date:  2003-06       Impact factor: 2.258

3.  Injury and liability associated with monitored anesthesia care: a closed claims analysis.

Authors:  Sanjay M Bhananker; Karen L Posner; Frederick W Cheney; Robert A Caplan; Lorri A Lee; Karen B Domino
Journal:  Anesthesiology       Date:  2006-02       Impact factor: 7.892

4.  Use of anesthesia on the rise in gastrointestinal endoscopy.

Authors:  Basil Al-Awabdy; C Mel Wilcox
Journal:  World J Gastrointest Endosc       Date:  2013-01-16

5.  Prevention of hypoxemia: the simple, logical, but incorrect solution.

Authors:  J B Downs
Journal:  J Clin Anesth       Date:  1994 May-Jun       Impact factor: 9.452

6.  Accuracy of respiratory rate monitoring using a non-invasive acoustic method after general anaesthesia.

Authors:  O Mimoz; T Benard; A Gaucher; D Frasca; B Debaene
Journal:  Br J Anaesth       Date:  2012-02-08       Impact factor: 9.166

7.  The evaluation of a non-invasive respiratory volume monitor in surgical patients undergoing elective surgery with general anesthesia.

Authors:  Christopher J Voscopoulos; C Marshall MacNabb; Jordan Brayanov; Lizeng Qin; Jenny Freeman; Gary John Mullen; Diane Ladd; Edward George
Journal:  J Clin Monit Comput       Date:  2014-07-19       Impact factor: 2.502

8.  Propofol depresses the hypoxic ventilatory response during conscious sedation and isohypercapnia.

Authors:  R T Blouin; H A Seifert; H D Babenco; P F Conard; J B Gross
Journal:  Anesthesiology       Date:  1993-12       Impact factor: 7.892

9.  The accuracy, precision and reliability of measuring ventilatory rate and detecting ventilatory pause by rainbow acoustic monitoring and capnometry.

Authors:  Michael A E Ramsay; Mohammad Usman; Elaine Lagow; Minerva Mendoza; Emylene Untalan; Edward De Vol
Journal:  Anesth Analg       Date:  2013-04-30       Impact factor: 5.108

10.  Outpatient endoscopic retrograde cholangiopancreatography: Safety and efficacy of anesthetic management with a natural airway in 653 consecutive procedures.

Authors:  Basavana G Goudra; Preet Mohinder Singh; Ashish C Sinha
Journal:  Saudi J Anaesth       Date:  2013-07
View more
  15 in total

Review 1.  Journal of Clinical Monitoring and Computing 2016 end of year summary: respiration.

Authors:  D S Karbing; S E Rees; M B Jaffe
Journal:  J Clin Monit Comput       Date:  2017-03-02       Impact factor: 2.502

2.  Respiratory measurement using infrared thermography and respiratory volume monitor during sedation in patients undergoing endoscopic urologic procedures under spinal anesthesia.

Authors:  Jeongmin Kim; Jun Hwan Kwon; Eungjin Kim; Sun Kook Yoo; Cheung-Soo Shin
Journal:  J Clin Monit Comput       Date:  2018-11-14       Impact factor: 2.502

3.  Ventilation monitoring during moderate sedation in GI patients.

Authors:  Thomas J Ebert; Austin H Middleton; Nikhil Makhija
Journal:  J Clin Monit Comput       Date:  2015-12-01       Impact factor: 2.502

4.  Ventilatory responses at submaximal exercise intensities in healthy children and adolescents during the growth spurt period: a semi-longitudinal study.

Authors:  Fenfen Zhou; Xiaojian Yin; Kilian Phillipe; Aya Houssein; Steven Gastinger; Jacques Prioux
Journal:  Eur J Appl Physiol       Date:  2021-08-19       Impact factor: 3.078

5.  Low minute ventilation episodes during anesthesia recovery following intraperitoneal surgery as detected by a non-invasive respiratory volume monitor.

Authors:  Alexandre N Cavalcante; Yvette N Martin; Juraj Sprung; Jasmin Imsirovic; Toby N Weingarten
Journal:  J Clin Monit Comput       Date:  2017-12-20       Impact factor: 2.502

6.  Breathing variability during propofol/remifentanil procedural sedation with a single additional dose of midazolam or s-ketamine: a prospective observational study.

Authors:  O F C van den Bosch; R Alvarez-Jimenez; S G Schet; K Delfsma; S A Loer
Journal:  J Clin Monit Comput       Date:  2021-11-12       Impact factor: 1.977

7.  Photoplethysmography respiratory rate monitoring in patients receiving procedural sedation and analgesia for upper gastrointestinal endoscopy.

Authors:  Hugo R W Touw; Milou H Verheul; Pieter R Tuinman; Jeroen Smit; Deirdre Thöne; Patrick Schober; Christa Boer
Journal:  J Clin Monit Comput       Date:  2016-05-28       Impact factor: 2.502

8.  The relationship between minute ventilation and end tidal CO2 in intubated and spontaneously breathing patients undergoing procedural sedation.

Authors:  Jaideep H Mehta; George W Williams; Brian C Harvey; Navneet K Grewal; Edward E George
Journal:  PLoS One       Date:  2017-06-29       Impact factor: 3.240

9.  Time-Frequency Analysis of Non-Stationary Biological Signals with Sparse Linear Regression Based Fourier Linear Combiner.

Authors:  Yubo Wang; Kalyana C Veluvolu
Journal:  Sensors (Basel)       Date:  2017-06-14       Impact factor: 3.576

10.  Evaluation by various methods of the physiological mechanism of a high-flow nasal cannula (HFNC) in healthy volunteers.

Authors:  Miyuki Okuda; Nobuya Tanaka; Kazuyuki Naito; Takao Kumada; Koji Fukuda; Yuto Kato; Yuto Kido; Yutaro Okuda; Ryuji Nohara
Journal:  BMJ Open Respir Res       Date:  2017-07-20
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.