X-ray imaging techniques that capture variations in the x-ray phase can yield higher contrast images with lower x-ray dose than is possible with conventional absorption radiography. However, the extraction of phase information is often more difficult than the extraction of absorption information and requires a more sophisticated experimental arrangement. We here report a method for three-dimensional (3D) X-ray phase contrast computed tomography (CT) which gives quantitative volumetric information on the real part of the refractive index. The method is based on the recently developed X-ray speckle tracking technique in which the displacement of near field speckle is tracked using a digital image correlation algorithm. In addition to differential phase contrast projection images, the method allows the dark-field images to be simultaneously extracted. After reconstruction, compared to conventional absorption CT images, the 3D phase CT images show greatly enhanced contrast. This new imaging method has advantages compared to other X-ray imaging methods in simplicity of experimental arrangement, speed of measurement and relative insensitivity to beam movements. These features make the technique an attractive candidate for material imaging such as in-vivo imaging of biological systems containing soft tissue.
X-ray imaging techniques that capture variations in the x-ray phase can yield higher contrast images with lower x-ray dose than is possible with conventional absorption radiography. However, the extraction of phase information is often more difficult than the extraction of absorption information and requires a more sophisticated experimental arrangement. We here report a method for three-dimensional (3D) X-ray phase contrast computed tomography (CT) which gives quantitative volumetric information on the real part of the refractive index. The method is based on the recently developed X-ray speckle tracking technique in which the displacement of near field speckle is tracked using a digital image correlation algorithm. In addition to differential phase contrast projection images, the method allows the dark-field images to be simultaneously extracted. After reconstruction, compared to conventional absorption CT images, the 3D phase CT images show greatly enhanced contrast. This new imaging method has advantages compared to other X-ray imaging methods in simplicity of experimental arrangement, speed of measurement and relative insensitivity to beam movements. These features make the technique an attractive candidate for material imaging such as in-vivo imaging of biological systems containing soft tissue.
X-rays have been used for imaging since their discovery in the late 19th
century as hard X-rays are sufficiently penetrating to pass through biological tissue.
The simplest X-ray imaging technique is radiography, where a beam of X-rays pass through
a sample and the transmitted intensity is recorded on an area detector. Computed
tomography (CT) scanning allows reconstruction of the X-ray absorption as a function of
position along the beam path to give a three-dimensional (3D) map of the absorption in
the sample. CT scanning using absorption radiography is widely used as a medical
diagnostic tool. Absorption contrast is however weak, if the elemental composition and
density do not vary significantly within the specimen. This lack of sensitivity makes
imaging of biological structures, such as blood vessels in soft tissues, difficult when
using absorption-based imaging. Sample dose in absorption based imaging is also a major
problem for biological systems, as radiation damage causes structural changes.The propagation of X-rays depends on the complex X-ray refractive index n =
1-δ-iβ where the imaginary part (iβ) gives rise to X-ray
absorption and the real part decrement (δ) gives rise to a phase shift. The
absorption term is responsible for the contrast observed in absorption radiography and
also for radiation dose in the sample. Conversely, the phase shift term generates
contrast in phase sensitive radiography but does not cause any sample radiation dose. In
addition, spatial variation of the electron density causes scattering by diffraction
which results in contrast in the dark-field image. This scattering is stronger when the
gradient of the electron density is higher and hence the dark-field image is most
sensitive to small structures within the sample.In the hard X-ray region at X-ray energies away from absorption edges, the absorption
term δ falls more rapidly with X-ray energy than the phase shift term
iβ. Above 10 keV, for biological samples composed of light
elements (carbon, oxygen, hydrogen etc.), δ is typically three orders of
magnitude larger than β and therefore phase sensitive imaging can allow high
contrast with lower radiation dose than conventional absorption radiography. Phase
contrast techniques have become more widespread with the availability of intense
synchrotron radiation X-ray sources and more efficient X-ray detectors with sub-micron
spatial resolution1234567. Additionally, dark-field imaging
can provide information on the structure of the objects at a scale where the scattering
features are smaller than the spatial resolution of the technique8910111213. Dark-field imaging was first introduced in electron
microscopy in the late 1930s and it has taken a further 70 years for it to be realized
with X-ray light, mainly due to the lack of efficient X-ray optics8910.Although several X-ray phase contrast imaging techniques have been developed in the past
two decades that are capable of imaging soft tissue, only analyzer-based and
grating-based methods are commonly used to obtain both phase and dark-field
contrast3711141516. The analyzer based technique uses a
Bragg reflecting perfect single crystal with low angular acceptance in order to measure
deflection of the wavefront, however detected intensity is low resulting in a poor
signal to noise ratio, the stability requirements are stringent and the technique is
sensitive to deflections in only one direction. The grating based technique has been
increasing in popularity, especially since its adaptation to low brilliance X-ray tube
sources1117. The Moiré fringe analysis mode only requires a
single fringe image1819, but the resolution becomes limited by the
fringe or grid spacing when working with 2D interferometers2021. To
increase the spatial resolution the measurements are frequently done in phase-stepping
mode where one grating is scanned relative to the other, transversely to the incident
beam16. This, however, results in an increased radiation dose in the
sample.In this letter, we describe a new approach for X-ray phase contrast tomography based on
the tracking of X-ray near-field speckle, a technique that was originally developed for
two-dimensional (2D) X-ray wavefront sensing and imaging222324. We
demonstrate extension of the X-ray speckle tracking (XST) method from 2D projection to
give 3D volumetric phase information using CT reconstruction and we also show how the
approach can be extended to the simultaneous retrieval of dark-field images. To
demonstrate the capabilities of the XST CT technique and its potential application to
biomedical research, we present data collected on an ex vivo human carotid artery
specimen2526.The experimental set-up is relatively simple involving only the specimen, an X-ray
imaging detector and a phase object containing random high spatial frequency structures,
for example a biological filtering membrane or a sheet of abrasive paper. The choice of
material and structure size of the phase object depends on the X-ray energy, the setup
geometry and the detector resolution. The experimental layout is shown in Fig. 1. In Fig. 1a, a partially coherent X-ray beam
passes through the abrasive paper and a speckle pattern is produced on the detector
caused by interference of the randomly scattered radiation. One image is firstly taken
of the speckle and then a second image is taken with the specimen inserted (Fig. 1b). Fig. 1c and Fig.
1d show a small subset of the two speckle images. In order to track the
changes to the speckle between the two images, a digital image correlation algorithm
(DIC) is employed27. DIC algorithms have been widely employed for
deformation of surface mapping where tracked displacement has been shown to be
measurable with sub-pixel accuracy. In our application of the correlation algorithm, the
subsets were normalized to increase robustness to illumination variation with time. The
speckle intensity for a subset with points (xi, yi)
in a target image and (xi, yi) of a reference image
is denoted by the functions f(xi, yi) and , respectively28. For a target
subset centred in pixel (x, y0), the normalized
correlation coefficient ri,j is defined aswhere the number of points along x or y is
2M + 1, and and Δf
(Δg) is the mean and standard deviation of the subset, respectively.
Figure 1
Schematic representation of the experiment setup.
Speckle image (a) without the specimen and (b) with the specimen and the
phase object (abrasive paper), (c) reference and (d) target subset speckle
image, (e) example of correlation coefficient map for the subset, (f)
horizontal and (g) vertical displacement and (h) correlation coefficient
image.
The relation between the position of the region without sample (xi,
yi) and with sample can be
writtenThe zero order term (u0, v0) describes a rigid body
translation of the subset with no change in the speckle pattern. The shape of the
reference region can however change between the two images: whilst the first-order term
models linear deformations (rotations, shears etc.) of the subset, higher order terms
are sometimes used to model more complicated non linear deformations. Scattering from
the sample due to strong and rapid variations in the electronic density decreases the
beam coherence and deforms locally the speckle pattern. Since the higher orders shape
functions account for deformations due to strong and rapid variations in the electronic
density, they also mirror the sample scattering. This translates in a reduction in the
correlation value between the reference and target subsets. This approach is fully
equivalent in principle to scattering properties mapping29, where the
correlation amplitude and tracking is calculated from a regular grid pattern rather than
here a random speckle pattern.Using equation (1), a correlation map can be generated for every
subset of each reference-sample image pair. Fig. 1e shows the
correlation map obtained from the reference subset (Fig. 1c) and
target subset (Fig. 1d). The peak value ri,j and
its position (ui,j, vi,j) in the correlation map is
calculated for each subset of each image. With ui,j and
vi,j corresponding to the in-plane local displacement vector of
the speckle pattern caused by refraction in the sample, two displacement maps (u,
v) can be made as shown in Fig. 1f and Fig. 1g. The wavefront gradient is calculated as the ratio of this rigid
body translation to the distance between the membrane and detector. The phase shift is
then derived from the two transverse phase gradients30. The corresponding
correlation coefficient map (r) is shown in Fig. 1h. The
correlation coefficient r is equal to unity if the subsets are related by a
simple translation and is smaller when the target speckle pattern is distorted due to
scattering. The correlation coefficient is related therefore to the scattering from the
sample and can be used to generate a dark-field image.
Results
Fig. 2 shows one of the projection images obtained using the
XST technique applied to a human carotid artery sample. The field of view was
3.4 mm vertically by 6.2 mm horizontally. An X-ray transmission image
is shown in Fig. 2a, and Fig. 2b and
Fig. 2c show images of the dark-field and phase signals
respectively. The X-ray phase gradients in the horizontal (x) and vertical
(y) directions were calculated from the speckle displacement (u,
v) of Fig. 1f and Fig.
1g22. The phase shift induced by the artery sample shown
in Fig. 2b was reconstructed using the two transverse phase
gradients as an input into a pseudo-inversion matrix algorithm. Since the
correlation coefficient reduces as the scattering power increases, the dark-field
image (df) of Fig. 2b was calculated by subtraction of
the correlation coefficient map (Fig. 1h) from unity with
df = 1-r.
Figure 2
Transmission, dark-field and projected phase image for a human carotid
artery.
(a) Transmission image, (b) dark-field image, (c) projected phase image and
(d) section profiles across the corresponding images of the artery sample
(indicated by the coloured line in each image).
In Fig. 2a, the metal stent together with one identified fibre
outside of the plastic Eppendorf tube are clearly visible in the conventional
radiograph. It should be noted that the transmission at the bottom of the image is
slightly higher than the rest of the image. This was caused by detector background
which could be improved with a dark field correction to the data. As shown in Fig. 2a, the presence of small features in this image is
observable due to propagation-based phase contrast edge enhancement. In contrast,
the dark-field contrast image (Fig. 2b) yields stronger
contrast in regions with more inhomogeneous material and at the feature edges since
they scatter more. Thus, scattering information from fibre and the metal stent are
clearly visible in the dark-field image. The corresponding projected phase image
(Fig. 2c) shows that the phase change is dominated by the
Eppendorf tube rather than the sample. As we shall see further, upon CT
reconstruction, the sample phase change becomes clearly distinguishable from the
container phase shift and the differences in sample density can be best visualized
from the reconstructed CT image. Fig. 2(d) shows line profiles
marked by the dashed lines in the transmission, dark-field and the phase images. As
a comment, one can note that the scattering from the metal stent is much stronger
than from the sample even though the transmission signals are similar to each other.
Hence, the dark-field image reveals complementary information to the transmission
and phase images.CT reconstructions were performed using both the transmission and phase image sets.
The acquisitions were obtained with the sample mounted on a vertical rotation axis.
A set of 900 projections with orientation angles ranging from 0° to 180°
were used. Phase signal for all the speckle images were calculated on a parallel
processing Central Processing Unit (CPU) computation cluster and later the volume
reconstruction was done on a Graphics Processing Unit (GPU) cluster. Fig. 3a and Fig. 3b show the transmission and
phase reconstructions of the artery specimen. The volume reconstruction from
transmission projection reveals very fine structure in its rendering (mostly in
fatty tissue), contrary to the reconstruction from the phase image which reveals
more clearly the artery vessel.
Figure 3
3D rendering of the tomographic reconstruction.
Volume rendering from (a) transmission and (b) phase slices.
Axial axis slices of the displayed reconstructions in Fig. 3
are shown in Fig. 4. Such a view provides an easier way to
compare the phase (Fig. 4b) and absorption (Fig. 4a) information. On one hand, the transmission signal shows strong
edge enhancement from interference due to the high coherence of the X-ray beam. One
can observe in this slice the fatty tissue, small features showing a high level of
detail. This is illustrated by the micro calcifications present in the vessel wall
circled in yellow in Fig. 4. On the other hand, the phase
slice shows more contrast between the artery lumen and fat, detail that is less
visible in the transmission image.
Figure 4
Reconstructed axial slices of the artery specimen.
(a) Transmission and (b) phase axial slice, (c) and (d) are line profiles of
the image greyscale (8 bit) at the positions indicated by the thin
lines from (a) and (b).
Line profiles for the absorption and phase slices are highlighted in Fig. 4c and Fig. 4d. Again, spatial high frequency
features are less visible in the phase slice compared to the absorption slice that
benefits from the edge enhancement effect. Nevertheless, there is a clear
distinction in contrast between sample materials; the line profiles in Fig. 4 clearly show a consistently higher brightness of the
lumen over the fat material in the phase image (Fig. 4d)
whereas the brightness is much closer in the absorption image (Fig.
4c). The lower spatial resolution of the phase slice is exacerbated by
the requirement that several pixels be used to track the speckle displacement with
the digital correlation algorithm22.
Summary and Discussion
In summary, the speckle tracking technique has been used to generate multiple phase
contrast and dark-field images of a human carotid artery sample at different
projection angles. Computed tomography reconstruction was then performed to image a
specimen containing a human carotid artery. With a simple experimental arrangement,
the speckle based technique is easily implementable at a synchrotron radiation
beamline since no perfect crystals analysers or precision gratings are required.
Moreover, the speckle based technique causes low sample dosage relative to other
differential phase contrast imaging techniques as only a single exposure of the
sample is required per projection. A low radiation dose is of particular value for
in vivo phase contrast imaging of biological samples. The technique gives good phase
sensitivity as a result of the sub-pixel accuracy of the DIC algorithms for
measuring the speckle displacement. The distance between the membrane and the
detector can be increased to several meters provided the beam transverse coherence
is large enough to magnify the speckle displacement, and thus improves the
sensitivity to the phase shift. The method is also only moderately demanding in
terms of beam stability as only a pair of short exposure images are required, and
the normalized correlation criterion renders the process insensitive to illumination
changes28. At present, the computation time for data analysis can
seem long, however this could be reduced by improving the efficiency of the digital
correlation algorithm or by writing the code in a compiled language such as C. A
further development would be to increase the spatial resolution by scanning the
membrane either in one or two dimensions2324. This processing would
however require a much larger number of exposures and is then less attractive for
dose sensitive samples. Another possible development would be application of the
technique at higher X-ray energies replacing the phase object with a scattering
object made of a heavier material. Preliminary test have shown that the speckle
tracking could be efficient from 50 keV to 100 keV. Finally, XST based
phase contrast imaging has been recently demonstrated using lab-based sources31, increasing the potential for applications in biology, medicine,
non-destructive testing, food inspection and security.
Methods
The initial experiment was performed on the Test beamline B16 at Diamond Light
Source, and the data presented in this study were collected at the PETRA III
beamline P05. A monochromatic beam produced by a double crystal monochromator
(ΔE/E ≈ 10−4) at an X-ray energy of 15 keV and
cut down to a cross section of 6.2 mm × 3.4 mm was calculated to
give an X-ray flux of 4.5 × 1013
photons/mm2/sec. The random phase object was a sheet of silicon
carbide abrasive paper (FEPA Grit P3000 with average particle diameter of
6.5 μm) which was mounted in the X-ray beam at a distance of
87.5 m from the source and close to the sample. The distance between the
membrane and the detector was set to the maximum mechanically achievable length of
0.89 m in order to increase the sensitivity. The speckle pattern was recorded
with a high-resolution imaging X-ray microscope with effective pixel size of 2.5
× 2.5 μm2. This imaging system consisted of a
CdWO4 scintillator (250 μm thick) producing a
visible-light image of the X-ray beam, a microscope objective, a mirror reflecting
at 90°, and a PCO 4000 CCD camera with the physical pixel size of
12 μm × 12 μm and the exposure time was 1.2 seconds for
each sample orientation. The sample was mounted on a vertical axis rotation stage
and measurements were taken at angles from 0° to 180° in steps of 0.2°.
After each 30° of rotation, 20 reference images of the membrane speckle with no
sample present were taken to minimize the effect from beam instability due to the
double crystal monochromator cooling system.
Sample preparation
The specimen was provided by the Institute of Clinical Radiology,
Ludwig-Maximilians-University Hospital (Munich, Germany) in accordance with the
Declaration of Helsinki and approved by the local ethics committee. The artery
was scanned in a plastic Eppendorf tube (10 mm diameter) fixated in a 4%
buffered formaldehyde solution. A metal stent was used to mark the region of
interest of the artery. The measurement was focused on the vessel part mainly
consisting of fatty tissue.
Reconstruction
Data processing was performed using a program run in Matlab version 2012b. The
subset used in our analysis was of 11 × 11 pixels in size which gives a
good compromise between accuracy and spatial resolution. Due to rapidly changing
phase at the edges of the sample container, a mask was applied to the projected
phase image to minimize the reconstructed phase error. Here, the edges of the
sample container are defined as the mask boundary, and the phase outside of the
mask boundary is set to zero. The compiled Matlab code was run using parallel
processing distributed over 30 nodes of the Diamond Light Source computation
cluster, taking 66 minutes to process all of the 900 datasets. Tomographic
reconstruction was then performed on absorption and phase-shift images which
were downsampled by 3, using 8 GPU accelerated computation nodes. The
reconstruction algorithm was of the parallel-beam filtered-back-projection kind
with GPU acceleration implemented in the CUDA programming language (Nvidia, USA)
for speed. Ring artefact suppression was applied with the algorithm of Titarenko
et al32.
Author Contributions
H.W., K.S., S.B. and J.H. planned and designed the experiment. J.H., H.W. and A.H.
conducted the experiment. H.W. and S.B. did the data analysis. R.A. and H.W.
performed the tomographic reconstruction. H.W., D.L., S.B. and K.S. wrote the
manuscript with inputs from all authors.
Authors: Timm Weitkamp; Ana Diaz; Christian David; Franz Pfeiffer; Marco Stampanoni; Peter Cloetens; Eric Ziegler Journal: Opt Express Date: 2005-08-08 Impact factor: 3.894
Authors: I Zanette; T Zhou; A Burvall; U Lundström; D H Larsson; M Zdora; P Thibault; F Pfeiffer; H M Hertz Journal: Phys Rev Lett Date: 2014-06-26 Impact factor: 9.161
Authors: Tobias Saam; Julia Herzen; Holger Hetterich; Sandra Fill; Marian Willner; Marco Stockmar; Klaus Achterhold; Irene Zanette; Timm Weitkamp; Ulrich Schüller; Sigrid Auweter; Silvia Adam-Neumair; Konstantin Nikolaou; Maximilian F Reiser; Franz Pfeiffer; Fabian Bamberg Journal: PLoS One Date: 2013-09-09 Impact factor: 3.240
Authors: Hongchang Wang; Robert C Atwood; Matthew James Pankhurst; Yogesh Kashyap; Biao Cai; Tunhe Zhou; Peter David Lee; Michael Drakopoulos; Kawal Sawhney Journal: Sci Rep Date: 2019-06-20 Impact factor: 4.379