Literature DB >> 25730825

3D Microendoscopic Electrical Impedance Tomography for Margin Assessment During Robot-Assisted Laparoscopic Prostatectomy.

Aditya Mahara, Shadab Khan, Ethan K Murphy, Alan R Schned, Elias S Hyams, Ryan J Halter.   

Abstract

Radially configured microendoscopic electrical impedance probes intended for intraoperative surgical margin assessment during robot-assisted laparoscopic prostatectomy (RALP) were examined through simulation, bench-top experimentation, and ex vivo tissue studies. Three probe designs with 8, 9, and 17 electrodes, respectively, were analyzed through finite element method based simulations. One mm diameter spherical inclusions ( σinclusion = 1 S/m) are positioned at various locations within a hemispherical background ( σbackground = 0.1 S/m) of radius 5 mm. An 8-electrode configuration is not able to localize the inclusion at these positions while 9 and 17-electrode configurations are able to accurately reconstruct the inclusion at maximum depth of 1 mm and 3 mm, respectively. All three probe designs were constructed and evaluated using saline phantoms and ex vivo porcine and human prostate tissues. The 17-electrode probe performed best in saline phantom studies, accurately reconstructing high contrast, 1-mm-diameter metal cylindrical inclusions in a saline bath ( σsaline = 0.1 S/m) with a position and area error of 0.46 mm and 0.84 mm2, respectively. Additionally, the 17-electrode probe was able to adequately distinguish cancerous from benign tissues in three ex vivo human prostates. Simulations, bench-top saline experiments, and ex vivo tissue sampling suggest that for intraoperative surgical margin assessment during RALP, the 17-electrode probe (as compared to an 8 and 9 electrode probe) will be necessary to provide sufficient accuracy and sensitivity.

Entities:  

Year:  2015        PMID: 25730825     DOI: 10.1109/TMI.2015.2407833

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  5 in total

1.  Prostate Cancer Detection Using Composite Impedance Metric.

Authors:  Shadab Khan; Aditya Mahara; Elias S Hyams; Alan R Schned; Ryan J Halter
Journal:  IEEE Trans Med Imaging       Date:  2016-06-09       Impact factor: 10.048

2.  Comparative study of separation between ex vivo prostatic malignant and benign tissue using electrical impedance spectroscopy and electrical impedance tomography.

Authors:  Ethan K Murphy; Aditya Mahara; Shadab Khan; Elias S Hyams; Alan R Schned; Jason Pettus; Ryan J Halter
Journal:  Physiol Meas       Date:  2017-03-10       Impact factor: 2.833

3.  Absolute Reconstructions Using Rotational Electrical Impedance Tomography for Breast Cancer Imaging.

Authors:  Ethan K Murphy; Aditya Mahara; Ryan J Halter
Journal:  IEEE Trans Med Imaging       Date:  2016-12-15       Impact factor: 10.048

4.  An Ex Vivo Study of Outward Electrical Impedance Tomography (OEIT) for Intravascular Imaging.

Authors:  Yuan Luo; Dong Huang; Zi-Yu Huang; Tzung K Hsiai; Yu-Chong Tai
Journal:  IEEE Trans Biomed Eng       Date:  2022-01-21       Impact factor: 4.538

Review 5.  The clinical application of electrical impedance technology in the detection of malignant neoplasms: a systematic review.

Authors:  Angela A Pathiraja; Ruwan A Weerakkody; Alexander C von Roon; Paul Ziprin; Richard Bayford
Journal:  J Transl Med       Date:  2020-06-08       Impact factor: 5.531

  5 in total