Literature DB >> 25725303

MRI noise estimation and denoising using non-local PCA.

José V Manjón1, Pierrick Coupé2, Antonio Buades3.   

Abstract

This paper proposes a novel method for MRI denoising that exploits both the sparseness and self-similarity properties of the MR images. The proposed method is a two-stage approach that first filters the noisy image using a non local PCA thresholding strategy by automatically estimating the local noise level present in the image and second uses this filtered image as a guide image within a rotationally invariant non-local means filter. The proposed method internally estimates the amount of local noise presents in the images that enables applying it automatically to images with spatially varying noise levels and also corrects the Rician noise induced bias locally. The proposed approach has been compared with related state-of-the-art methods showing competitive results in all the studied cases.
Copyright © 2015 Elsevier B.V. All rights reserved.

Keywords:  Denoising; MRI; Non-local means; PCA; Sparseness

Mesh:

Year:  2015        PMID: 25725303     DOI: 10.1016/j.media.2015.01.004

Source DB:  PubMed          Journal:  Med Image Anal        ISSN: 1361-8415            Impact factor:   8.545


  23 in total

1.  Denoising of 3D magnetic resonance images with multi-channel residual learning of convolutional neural network.

Authors:  Dongsheng Jiang; Weiqiang Dou; Luc Vosters; Xiayu Xu; Yue Sun; Tao Tan
Journal:  Jpn J Radiol       Date:  2018-07-07       Impact factor: 2.374

2.  Registration-based image enhancement improves multi-atlas segmentation of the thalamic nuclei and hippocampal subfields.

Authors:  Shunxing Bao; Camilo Bermudez; Yuankai Huo; Prasanna Parvathaneni; William Rodriguez; Susan M Resnick; Pierre-François D'Haese; Maureen McHugo; Stephan Heckers; Benoit M Dawant; Ilwoo Lyu; Bennett A Landman
Journal:  Magn Reson Imaging       Date:  2019-03-15       Impact factor: 2.546

3.  Adaptive anatomical preservation optimal denoising for radiation therapy daily MRI.

Authors:  Rapeepan Maitree; Gloria J Guzman Perez-Carrillo; Joshua S Shimony; H Michael Gach; Anupama Chundury; Michael Roach; H Harold Li; Deshan Yang
Journal:  J Med Imaging (Bellingham)       Date:  2017-09-01

4.  Nonlocal Means Denoising of Self-Gated and k-Space Sorted 4-Dimensional Magnetic Resonance Imaging Using Block-Matching and 3-Dimensional Filtering: Implications for Pancreatic Tumor Registration and Segmentation.

Authors:  Jun Jin; Elizabeth McKenzie; Zhaoyang Fan; Richard Tuli; Zixin Deng; Jianing Pang; Benedick Fraass; Debiao Li; Howard Sandler; Guang Yang; Ke Sheng; Shuiping Gou; Wensha Yang
Journal:  Int J Radiat Oncol Biol Phys       Date:  2016-02-06       Impact factor: 7.038

5.  Evaluation of principal component analysis image denoising on multi-exponential MRI relaxometry.

Authors:  Mark D Does; Jonas Lynge Olesen; Kevin D Harkins; Teresa Serradas-Duarte; Daniel F Gochberg; Sune N Jespersen; Noam Shemesh
Journal:  Magn Reson Med       Date:  2019-02-05       Impact factor: 4.668

6.  Artifact- and content-specific quality assessment for MRI with image rulers.

Authors:  Ke Lei; Ali B Syed; Xucheng Zhu; John M Pauly; Shreyas S Vasanawala
Journal:  Med Image Anal       Date:  2022-01-20       Impact factor: 8.545

7.  A post-processing method based on interphase motion correction and averaging to improve image quality of 4D magnetic resonance imaging: a clinical feasibility study.

Authors:  Zixin Deng; Jianing Pang; Yi Lao; Xiaoming Bi; Guan Wang; Yuhua Chen; Matthias Fenchel; Richard Tuli; Debiao Li; Wensha Yang; Zhaoyang Fan
Journal:  Br J Radiol       Date:  2019-01-03       Impact factor: 3.039

8.  Denoising of diffusion MRI using random matrix theory.

Authors:  Jelle Veraart; Dmitry S Novikov; Daan Christiaens; Benjamin Ades-Aron; Jan Sijbers; Els Fieremans
Journal:  Neuroimage       Date:  2016-08-11       Impact factor: 6.556

9.  Multi-shot diffusion-weighted MRI reconstruction with magnitude-based spatial-angular locally low-rank regularization (SPA-LLR).

Authors:  Yuxin Hu; Xiaole Wang; Qiyuan Tian; Grant Yang; Bruce Daniel; Jennifer McNab; Brian Hargreaves
Journal:  Magn Reson Med       Date:  2019-10-08       Impact factor: 4.668

10.  Joint low-rank prior and difference of Gaussian filter for magnetic resonance image denoising.

Authors:  Zhen Chen; Zhiheng Zhou; Saifullah Adnan
Journal:  Med Biol Eng Comput       Date:  2021-02-13       Impact factor: 2.602

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.