Literature DB >> 25720622

Comparison of everolimus- and biolimus-eluting coronary stents with everolimus-eluting bioresorbable vascular scaffolds.

Serban Puricel1, Diego Arroyo1, Noé Corpataux1, Gérard Baeriswyl1, Sonja Lehmann1, Zacharenia Kallinikou1, Olivier Muller1, Ludovic Allard1, Jean-Christophe Stauffer1, Mario Togni1, Jean-Jacques Goy1, Stéphane Cook2.   

Abstract

BACKGROUND: The first CE-approved bioresorbable vascular scaffold (BVS) is effective at treating simple lesions and stable coronary artery disease, but it has yet to be assessed versus the best-in-class drug-eluting stents (DES).
OBJECTIVES: This study sought to compare the performance of a BVS with that of everolimus-eluting stents (EES) and biolimus-eluting stents (BES) in all-comer patients.
METHODS: The EVERBIO II (Comparison of Everolimus- and Biolimus-Eluting Stents With Everolimus-Eluting Bioresorbable Vascular Scaffold Stents II) trial was a single-center, assessor-blinded study of 240 patients randomly assigned in a 1:1:1 ratio to EES, BES, or BVS. The only exclusion criterion was a reference vessel diameter >4.0 mm, which precluded treatment with BVS. The primary endpoint was angiographic late lumen loss (LLL) at 9 months. Secondary endpoints included patient-oriented major acute coronary events (MACE) (death, myocardial infarction [MI], and any revascularization), device-oriented MACE (cardiac death, MI, and target lesion revascularization), and stent thrombosis at the 9-month clinical follow-up.
RESULTS: Follow-up angiography was performed in 216 patients (90.7%) at 9 months. In-stent LLL was similar between patients treated with BVS (0.28 ± 0.39 mm) and those treated with EES/BES (0.25 ± 0.36 mm; p = 0.30). Clinical outcomes were similar at 9 months: the patient-oriented MACE rate was 27% in BVS and 26% in the EES/BES group (p = 0.83) and the device-oriented MACE rate was 12% in BVS and 9% in the EES/BES group (p = 0.6).
CONCLUSIONS: New-generation metallic DES (EES/BES) were not superior to BVS in terms of angiographic LLL and clinical outcomes. (Comparison of Everolimus- and Biolimus-Eluting Stents With Everolimus-Eluting Bioresorbable Vascular Scaffold Stents [EVERBIO II]; NCT01711931).
Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  coronary artery disease; drug-eluting stent(s); late lumen loss; myocardial infarction; percutaneous coronary intervention

Mesh:

Substances:

Year:  2015        PMID: 25720622     DOI: 10.1016/j.jacc.2014.12.017

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  43 in total

1.  TLR3 and TLR4 as potential clinical biomarkers for in-stent restenosis in drug-eluting stents patients.

Authors:  Shao Liang; Ma Aiqun; Li Jiwu; Zhang Ping
Journal:  Immunol Res       Date:  2016-04       Impact factor: 2.829

Review 2.  Bioresorbable Scaffolds for Coronary Artery Disease.

Authors:  Ashwin Nathan; Taisei Kobayashi; Daniel M Kolansky; Robert L Wilensky; Jay Giri
Journal:  Curr Cardiol Rep       Date:  2017-01       Impact factor: 2.931

3.  Two-by-two cross-over study to evaluate agreement between versions of a quantitative coronary analysis system (QAngio XA).

Authors:  Kayoko Kozuma; Kosuke Kashiwabara; Tomohiro Shinozaki; Ken Kozuma; Koji Oba; Yutaka Matsuyama
Journal:  Int J Cardiovasc Imaging       Date:  2017-01-21       Impact factor: 2.357

Review 4.  A review of bioresorbable scaffolds: hype or hope?

Authors:  Huay Cheem Tan; Rajiv Ananthakrishna
Journal:  Singapore Med J       Date:  2016-11-21       Impact factor: 1.858

5.  Bioresorbable scaffolds: should we stay simple or go complex?

Authors:  Luis Ortega-Paz; Salvatore Brugaletta; Hector M Garcia-Garcia; Manel Sabaté
Journal:  Cardiovasc Diagn Ther       Date:  2017-06

Review 6.  Single or dual antiplatelet therapy after PCI.

Authors:  Yosuke Miyazaki; Pannipa Suwannasom; Yohei Sotomi; Mohammad Abdelghani; Karthik Tummala; Yuki Katagiri; Taku Asano; Erhan Tenekecioglu; Yaping Zeng; Rafael Cavalcante; Carlos Collet; Yoshinobu Onuma; Patrick W Serruys
Journal:  Nat Rev Cardiol       Date:  2017-02-09       Impact factor: 32.419

7.  Overlapping meta-analyses of bioresorbable vascular scaffolds versus everolimus-eluting stents: bringing clarity or confusion?

Authors:  Davide Capodanno
Journal:  J Thorac Dis       Date:  2016-07       Impact factor: 2.895

Review 8.  Bioresorbable Stents in PCI.

Authors:  Daniel Lindholm; Stefan James
Journal:  Curr Cardiol Rep       Date:  2016-08       Impact factor: 2.931

Review 9.  Bioresorbable vascular scaffolds - basic concepts and clinical outcome.

Authors:  Ciro Indolfi; Salvatore De Rosa; Antonio Colombo
Journal:  Nat Rev Cardiol       Date:  2016-09-29       Impact factor: 32.419

10.  Time-Varying Outcomes With the Absorb Bioresorbable Vascular Scaffold During 5-Year Follow-up: A Systematic Meta-analysis and Individual Patient Data Pooled Study.

Authors:  Gregg W Stone; Takeshi Kimura; Runlin Gao; Dean J Kereiakes; Stephen G Ellis; Yoshinobu Onuma; Bernard Chevalier; Charles Simonton; Ovidiu Dressler; Aaron Crowley; Ziad A Ali; Patrick W Serruys
Journal:  JAMA Cardiol       Date:  2019-12-01       Impact factor: 14.676

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.