Literature DB >> 25715899

Visibility and variability of pleural fissures on normal digital chest radiographs of 1,000 healthy adults.

Thitiporn Suwatanapongched1, Chinnarat Bua-Ngam, Warawut Sukkasem, Hathaichanok Choochuay, Parinda Charee, Suvipaporn Siripornpitak.   

Abstract

PURPOSE: To investigate the visibility and variability of pleural fissures on digital chest radiographs.
METHODS: Posteroanterior digital chest radiographs of 566 males and 434 females were retrospectively reviewed for the frequencies and/or appearances of various pleural fissures.
RESULTS: The right only, left only and bilateral minor fissures were visible in 722 (72.2 %), 1 (0.1 %) and 7 (0.7 %) subjects, respectively. The right minor fissures were visible as more than one line in 219 (30.0 %) subjects, i.e., 2, 3 and 4 lines in 214 (29.3 %), 4 (0.5 %) and 1 (0.1 %), respectively. The 955 visible right minor fissures exhibited variable length (<1/3 of right hemithorax, 17.8 %; 1/3-2/3, 60.1 %; >2/3, 22.1 %), alignment (medial higher 40.9 %; lateral higher 54.2 %; horizontal 4.8 %) and contour (convex upward 68.6 %; convex downward 2.7 %; flat 24.9 %; sigmoid 3.8 %). Superolateral major fissures were visualized in 14.8 % (right only 3.0 %; left only 9.0 %; bilateral 2.8 %), superomedial major fissures in 0.3 % (right 0.1 %; left 0.2 %), vertical fissures in 0.5 % (right 0.2 %; left 0.3 %), inferior accessory fissures in 5.4 % (right 4.8 %; left 0.6 %), right superior accessory fissures in 1.2 % and azygos fissures in 0.2 %.
CONCLUSION: The right minor fissure was most frequently visible and exhibited variable appearances. Other pleural fissures were occasionally seen.

Entities:  

Mesh:

Year:  2015        PMID: 25715899     DOI: 10.1007/s11604-015-0402-9

Source DB:  PubMed          Journal:  Jpn J Radiol        ISSN: 1867-1071            Impact factor:   2.374


  20 in total

1.  Accessory fissures of the lung: evaluation by high-resolution computed tomography.

Authors:  O M Ariyürek; M Gülsün; F B Demirkazik
Journal:  Eur Radiol       Date:  2001-05-19       Impact factor: 5.315

2.  High resolution CT anatomy of the pulmonary fissures.

Authors:  Aamer Aziz; Kazuto Ashizawa; Kenji Nagaoki; Kuniaki Hayashi
Journal:  J Thorac Imaging       Date:  2004-07       Impact factor: 3.000

3.  Imaging of the azygos lobe: normal anatomy and variations.

Authors:  J Mata; J Cáceres; X Alegret; P Coscojuela; J A De Marcos
Journal:  AJR Am J Roentgenol       Date:  1991-05       Impact factor: 3.959

Review 4.  Advances in digital radiography: physical principles and system overview.

Authors:  Markus Körner; Christof H Weber; Stefan Wirth; Klaus-Jürgen Pfeifer; Maximilian F Reiser; Marcus Treitl
Journal:  Radiographics       Date:  2007 May-Jun       Impact factor: 5.333

5.  The azygos lobe: normal variants that may simulate disease.

Authors:  J Caceres; J M Mata; J Andreu
Journal:  Eur J Radiol       Date:  1998-03       Impact factor: 3.528

6.  Digital radiography versus conventional radiography in chest imaging: diagnostic performance of a large-area silicon flat-panel detector in a clinical CT-controlled study.

Authors:  M Garmer; S P Hennigs; H J Jäger; F Schrick; T van de Loo; A Jacobs; A Hanusch; A Christmann; K Mathias
Journal:  AJR Am J Roentgenol       Date:  2000-01       Impact factor: 3.959

7.  Accessory fissures of the lung.

Authors:  J D Godwin; R D Tarver
Journal:  AJR Am J Roentgenol       Date:  1985-01       Impact factor: 3.959

8.  The superolateral major fissures.

Authors:  A V Proto; J B Ball
Journal:  AJR Am J Roentgenol       Date:  1983-03       Impact factor: 3.959

9.  Radiographic anatomy of the interlobar fissures: a study of 100 specimens.

Authors:  B N Raasch; E W Carsky; E J Lane; J P O'Callaghan; E R Heitzman
Journal:  AJR Am J Roentgenol       Date:  1982-06       Impact factor: 3.959

10.  Obliquely oriented superior accessory fissure of the lower lobe of the lung: CT evaluation of the normal appearance and effect on the distribution of parenchymal and pleural opacities.

Authors:  S D Davis; L S Yu; K D Hentel
Journal:  Radiology       Date:  2000-07       Impact factor: 11.105

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.