Literature DB >> 17495286

Advances in digital radiography: physical principles and system overview.

Markus Körner1, Christof H Weber, Stefan Wirth, Klaus-Jürgen Pfeifer, Maximilian F Reiser, Marcus Treitl.   

Abstract

During the past two decades, digital radiography has supplanted screen-film radiography in many radiology departments. Today, manufacturers provide a variety of digital imaging solutions based on various detector and readout technologies. Digital detectors allow implementation of a fully digital picture archiving and communication system, in which images are stored digitally and are available anytime. Image distribution in hospitals can now be achieved electronically by means of web-based technology with no risk of losing images. Other advantages of digital radiography include higher patient throughput, increased dose efficiency, and the greater dynamic range of digital detectors with possible reduction of radiation exposure to the patient. The future of radiography will be digital, and it behooves radiologists to be familiar with the technical principles, image quality criteria, and radiation exposure issues associated with the various digital radiography systems that are currently available. (c) RSNA, 2007.

Entities:  

Mesh:

Year:  2007        PMID: 17495286     DOI: 10.1148/rg.273065075

Source DB:  PubMed          Journal:  Radiographics        ISSN: 0271-5333            Impact factor:   5.333


  41 in total

1.  Radiation exposure of operator performing interventional procedures using a flat panel angiography system: evaluation with photoluminescence glass dosimeters.

Authors:  Yoshinori Funama; Nozomu Nagasue; Kazuo Awai; Ichiro Sakamoto; Kiyotaka Kakei; Masamichi Shimamura; Yasuyuki Yamashita; Masataka Uetani
Journal:  Jpn J Radiol       Date:  2010-07-27       Impact factor: 2.374

2.  Digital radiography, image archiving and image display: Practical tips.

Authors:  Robert Cruz
Journal:  Can Vet J       Date:  2008-11       Impact factor: 1.008

3.  Grey-scale inversion improves detection of lung nodules.

Authors:  J W Robinson; J T Ryan; M F McEntee; S J Lewis; M G Evanoff; L A Rainford; P C Brennan
Journal:  Br J Radiol       Date:  2012-05-09       Impact factor: 3.039

4.  Unified approach for bioluminescence, Cerenkov, β, X and γ rays imaging.

Authors:  Antonello E Spinelli; Carmen R Gigliotti; Federico Boschi
Journal:  Biomed Opt Express       Date:  2015-05-21       Impact factor: 3.732

5.  Optimal beam quality for chest flat panel detector system: realistic phantom study.

Authors:  Chie Kuwahara; Takatoshi Aoki; Nobuhiro Oda; Jun Kawabata; Koichiro Sugimoto; Michiko Kobayashi; Masami Fujii; Yukunori Korogi
Journal:  Eur Radiol       Date:  2019-02-08       Impact factor: 5.315

6.  Glowing nanocrystals enable 3D X-ray imaging.

Authors:  Albano N Carneiro Neto; Oscar L Malta
Journal:  Nature       Date:  2021-02       Impact factor: 49.962

7.  Grey-scale inversion improves detection of lung nodules.

Authors:  J W Robinson; J T Ryan; M F McEntee; S J Lewis; M G Evanoff; L A Rainford; P C Brennan
Journal:  Br J Radiol       Date:  2013-01       Impact factor: 3.039

8.  [Dose reduction and adequate image quality in digital radiography: a contradiction?].

Authors:  S Pötter-Lang; M Dünkelmeyer; M Uffmann
Journal:  Radiologe       Date:  2012-10       Impact factor: 0.635

9.  Evaluation of image quality and task performance for a mobile C-arm with a complementary metal-oxide semiconductor detector.

Authors:  Godwin O Abiola; Niral M Sheth; Wojciech Zbijewski; Matthew W Jacobson; Christopher Bailey; John Filtes; Gerhard Kleinszig; Sebastian K Vogt; Stefan Soellradl; Jens Bialkowski; William S Anderson; Jeffrey H Siewerdsen; Clifford R Weiss
Journal:  J Med Imaging (Bellingham)       Date:  2020-01-24

10.  Comparison of radiation dose, workflow, patient comfort and financial break-even of standard digital radiography and a novel biplanar low-dose X-ray system for upright full-length lower limb and whole spine radiography.

Authors:  Tobias J Dietrich; Christian W A Pfirrmann; Alexander Schwab; Katja Pankalla; Florian M Buck
Journal:  Skeletal Radiol       Date:  2013-03-28       Impact factor: 2.199

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.