Literature DB >> 25715041

Mechanical influence of thread pitch on orthodontic mini-implant stability.

Amanda Carneiro da Cunha1, Amanda Osório Ayres de Freitas1, Mariana Marquezan1, Lincoln Issamu Nojima1.   

Abstract

The aim of this study was to evaluate the effect of pitch distance on the primary stability (PS) of orthodontic mini-implants (MIs) in artificial bone. Twenty experimental MIs were allocated to two groups, according to their geometric design: G1 (30o X 0.6 mm) and G2 (45o X 0.8 mm), and inserted into artificial bone of different densities: D1 (0.32 g/cm3) and D2 (0.64 g/cm3). The maximum insertion torque (IT) and removal torque (RT) values were recorded in N.cm. Loss of torque (LT) values were obtained by calculating the difference between the IT and RT. MI mobility was measured by means of a Periotest assessment. Normality and homogeneity were determined by means of the Kolmogorov-Smirnov and Shapiro-Wilk tests, respectively. A two-way ANOVA was used to detect differences between the mini-implant design and density factors. The ANOVA/Tukey tests were used to determine the intergroup difference. Higher IT values were observed for G2 (p ≤ 0.05) in D2. No statistical difference for RT was observed between the groups, whereas G2 presented higher values only for LT (p ≤ 0.05). The Periotest values (PTV) were higher for G1, in comparison with G2, in D1. G1 presented better PS in D2 (IT, RT and LT), whereas G2 was found to be more stable in D1, after evaluation with Periotest.

Mesh:

Substances:

Year:  2015        PMID: 25715041     DOI: 10.1590/1807-3107BOR-2015.vol29.0042

Source DB:  PubMed          Journal:  Braz Oral Res        ISSN: 1806-8324


  5 in total

1.  Enhancing osseointegration of titanium implants through large-grit sandblasting combined with micro-arc oxidation surface modification.

Authors:  Wulin He; Xing Yin; Li Xie; Zeping Liu; Jingtao Li; Shujuan Zou; Jianwei Chen
Journal:  J Mater Sci Mater Med       Date:  2019-06-11       Impact factor: 3.896

2.  Influence of geometric design characteristics on primary stability of orthodontic miniscrews.

Authors:  Eman Saad Radwan; Mona A Montasser; Ahmed Maher
Journal:  J Orofac Orthop       Date:  2018-04-10       Impact factor: 1.938

3.  The effect of implant neck microthread design on stress distribution of peri-implant bone with different level: A finite element analysis.

Authors:  Zhi-Heng Jin; Meng-Dong Peng; Qing Li
Journal:  J Dent Sci       Date:  2019-12-31       Impact factor: 2.080

4.  Bone quality affects stability of orthodontic miniscrews.

Authors:  Wan-Ping Yu; Ming-Tzu Tsai; Jian-Hong Yu; Heng-Li Huang; Jui-Ting Hsu
Journal:  Sci Rep       Date:  2022-02-18       Impact factor: 4.379

5.  In vitro study of the orthodontic mini-implants influence on the growth of human osteoblasts.

Authors:  Andreea Moldoveanu; Mihnea Ioan Nicolescu; Mirela Veronica Bucur; George Gabriel Moldoveanu; Cristian Funieru; Ionela Victoria Neagoe; Gina Manda; Tamara Rahela Ioana; Lucian Toma Ciocan
Journal:  Rom J Morphol Embryol       Date:  2021 Jul-Sep       Impact factor: 0.833

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.