Literature DB >> 25711262

Simulation analysis of three intubating supraglottic devices during infant chest compression.

Hanako Kohama1, Nobuyasu Komasawa, Ryusuke Ueki, Yoshiroh Kaminoh, Shin-ichi Nishi.   

Abstract

Current guidelines for pediatric cardiopulmonary resuscitation suggest that supraglottic devices are alternatives for tracheal intubation with minimal interruption of chest compression. We examined the utility of three intubating supraglottic devices, air-Q® (air-Q), Ambu® aura-i (aura-i), and i-gel® (i-gel), utilizing manikin simulation. Twenty-two novice physicians performed securing of airway on an infant manikin with the three devices. We measured the rate of success on ventilation and the insertion time with or without chest compression. Successful ventilation rate did not significantly decrease with chest compression in the three devices (without chest compression: air-Q, 21/22; aura-i, 20/22; i-gel, 20/22, during chest compression: air-Q, 20/22; aura-i, 20/22; i-gel, 18/22). The insertion time with air-Q and aura-i did not extend significantly for chest compression. In contrast, the insertion time with i-gel was significantly extended in chest compression (P < 0.05). Air-Q and aura-i are more useful for airway management during chest compression than i-gel.
© 2015 Japan Pediatric Society.

Entities:  

Keywords:  chest compression; infant; intubating supraglottic device; manikin

Mesh:

Year:  2015        PMID: 25711262     DOI: 10.1111/ped.12541

Source DB:  PubMed          Journal:  Pediatr Int        ISSN: 1328-8067            Impact factor:   1.524


  4 in total

1.  Exchange of supraglottic airways for endotracheal tube using the Eschmann Introducer during simulated child resuscitation: A randomized study comparing 4 devices.

Authors:  Lukasz Szarpak; Zenon Truszewski; Joseph Vitale; Logan Glosser; Kurt Ruetzler; Antonio Rodríguez-Núñez
Journal:  Medicine (Baltimore)       Date:  2017-06       Impact factor: 1.889

2.  A Comparison between the i-gel® and air-Q® Supraglottic Airway Devices Used for the Patients Undergoing General Anesthesia with Muscle Relaxation.

Authors:  Nilofar Massoudi; Mohammad Fathi; Navid Nooraei; Alireza Salehi
Journal:  Biomed Res Int       Date:  2018-11-18       Impact factor: 3.411

3.  Clinical evaluation of Ambu® Aura-i™ - A new intubating laryngeal mask airway as an independent ventilatory device and a conduit for tracheal intubation in pediatric patients.

Authors:  Triveni M Rangaswamy; Avnish Bharadwaj; Priyanka Jain
Journal:  Int J Crit Illn Inj Sci       Date:  2019-12-11

4.  Comparison of Miller and Airtraq laryngoscopes for orotracheal intubation by physicians wearing CBRN protective equipment during infant resuscitation: a randomized crossover simulation study.

Authors:  Pierre-Géraud Claret; Renaud Asencio; Damien Rogier; Claire Roger; Philippe Fournier; Tu-Anh Tran; Mustapha Sebbane; Xavier Bobbia; Jean Emmanuel de La Coussaye
Journal:  Scand J Trauma Resusc Emerg Med       Date:  2016-03-22       Impact factor: 2.953

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.