Literature DB >> 25710394

[Reliability of Selected Parameters of Cycling Ergospirometry from the PowerCube-Ergo Respiratory Gas Analyser].

M W Hoppe1, B Sperlich2, C Baumgart1, M Janssen1, J Freiwald1.   

Abstract

This study aimed to investigate the reliability of 1) the key parameters of cycling ergospirometry (maximum power output [Pmax] and oxygen uptake [V̇O2peak], ventilatory thresholds 1 [VT 1] and 2 [VT 2], and cycling efficiency [CE] and gross efficiency [GE]), 2) the commonly used parameters to quantify exhaustion (maximum heart rate [HFmax], respiratory quotient [RQmax], blood lactate concentration [BLAmax], and ratings of perceived exhaustion [RPEmax]), and 3) the kinetics of exercise induced gas exchange measurements (oxygen uptake [V̇O2], carbon dioxide output [V̇CO2], and minute ventilation [V̇E]) using the PowerCube-Ergo metabolic system in consideration of international statistical recommendations. 12 women and 12 men (28 ± 4 years; 23.2 ± 2.4 kg/m(2)) performed two cycling tests (20 watt/min) separated by one week. The reliability was calculated based on differences in means (t test and effect sizes), retest correlation (intraclass correlation coefficient [ICC]), and within-subject variation (standard error of measurement [SEM]). Of the key parameters of cycling ergospirometry, an excellent reliability (ICC ≥ 0.969; p = 0.000) and high accuracy (%SEM ≤ 4.6) were found for Pmax, V̇O2peak, and VT 1. Of the most commonly used parameters to quantify exhaustion, an excellent reliability (ICC = 0.922; p = 0.000) and high accuracy (%SEM = 1.0) existed only for HFmax. The gas exchange measurements (V̇O2, V̇CO2 und V̇E) of the PowerCube-Ergo were all excellently reliable (ICC ≥ 0,991; p = 0.000) and the accuracy of V̇O2 (SEM = 0.10 l/min) and V̇E (SEM = 3.13 l/min) fulfilled the quality guidance of exercise physiology laboratories. For future studies and practical purposes, the results are vital for the decision as to whether a difference between two tests represents a true intervention effect or just a measurement error and for the estimation of required sample sizes. © Georg Thieme Verlag KG Stuttgart · New York.

Entities:  

Mesh:

Year:  2015        PMID: 25710394     DOI: 10.1055/s-0034-1399096

Source DB:  PubMed          Journal:  Sportverletz Sportschaden        ISSN: 0932-0555            Impact factor:   1.077


  4 in total

1.  Test-Retest Reliability of Non-Invasive Cardiac Output Measurement during Exercise in Healthy Volunteers in Daily Clinical Routine.

Authors:  Michael Thomas Coll Barroso; Matthias Wilhelm Hoppe; Philip Boehme; Thomas Krahn; Christian Kiefer; Frank Kramer; Thomas Mondritzki; Phillipe Pirez; Wilfried Dinh
Journal:  Arq Bras Cardiol       Date:  2019-07-10       Impact factor: 2.000

2.  Contrary to endurance, power associated capacities differ between different aged and starting-nonstarting elite junior soccer players.

Authors:  Matthias W Hoppe; Vadim Barnics; Jürgen Freiwald; Christian Baumgart
Journal:  PLoS One       Date:  2020-04-28       Impact factor: 3.240

3.  Spirometry has added value over electrodermal activity as a physiological marker of mental load in male subjects.

Authors:  Tobias Neukirchen; Moritz Stork; Matthias W Hoppe; Christian Vorstius
Journal:  Sci Rep       Date:  2022-03-16       Impact factor: 4.379

4.  Non-invasively measured central and peripheral factors of oxygen uptake differ between patients with chronic heart failure and healthy controls.

Authors:  Joana Brochhagen; Michael Thomas Coll Barroso; Christian Baumgart; Jürgen Freiwald; Matthias Wilhelm Hoppe
Journal:  BMC Cardiovasc Disord       Date:  2020-08-18       Impact factor: 2.298

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.