Literature DB >> 25706501

A Switched-Mode Breast Coil for 7 T MRI Using Forced-Current Excitation.

Jiaming Cui, John C Bosshard, Joseph V Rispoli, Ivan E Dimitrov, Sergey Cheshkov, Mary Preston McDougall, Craig Malloy, Steven M Wright.   

Abstract

In high-field magnetic resonance imaging, the radio frequency wavelength within the human body is comparable to anatomical dimensions, resulting in B1 inhomogeneity and nonuniform sensitivity patterns. Thus, this relatively short wavelength presents engineering challenges for RF coil design. In this study, a bilateral breast coil for (1)H imaging at 7 T was designed and constructed using forced-current excitation. By forcing equal current through the coil elements, we reduce the effects of coupling between the elements to simplify tuning and to ensure a uniform field across both breasts. To combine the benefits of the higher power efficiency of a unilateral coil with the bilateral coverage of a bilateral coil, a switching circuit was implemented to allow the coil to be reconfigured for imaging the left, right, or both breasts.

Entities:  

Mesh:

Year:  2015        PMID: 25706501      PMCID: PMC4626209          DOI: 10.1109/TBME.2015.2403850

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  27 in total

1.  Transmit SENSE.

Authors:  Ulrich Katscher; Peter Börnert; Christoph Leussler; Johan S van den Brink
Journal:  Magn Reson Med       Date:  2003-01       Impact factor: 4.668

2.  Parallel excitation with an array of transmit coils.

Authors:  Yudong Zhu
Journal:  Magn Reson Med       Date:  2004-04       Impact factor: 4.668

3.  B(1) destructive interferences and spatial phase patterns at 7 T with a head transceiver array coil.

Authors:  Pierre-François Van de Moortele; Can Akgun; Gregor Adriany; Steen Moeller; Johannes Ritter; Christopher M Collins; Michael B Smith; J Thomas Vaughan; Kāmil Uğurbil
Journal:  Magn Reson Med       Date:  2005-12       Impact factor: 4.668

4.  Transmit and receive transmission line arrays for 7 Tesla parallel imaging.

Authors:  Gregor Adriany; Pierre-Francois Van de Moortele; Florian Wiesinger; Steen Moeller; John P Strupp; Peter Andersen; Carl Snyder; Xiaoliang Zhang; Wei Chen; Klaas P Pruessmann; Peter Boesiger; Tommy Vaughan; Kāmil Uğurbil
Journal:  Magn Reson Med       Date:  2005-02       Impact factor: 4.668

Review 5.  Whole-body MRI at high field: technical limits and clinical potential.

Authors:  Fritz Schick
Journal:  Eur Radiol       Date:  2005-01-27       Impact factor: 5.315

6.  Clinical application of bilateral high temporal and spatial resolution dynamic contrast-enhanced magnetic resonance imaging of the breast at 7 T.

Authors:  K Pinker; W Bogner; P Baltzer; S Trattnig; S Gruber; O Abeyakoon; M Bernathova; O Zaric; P Dubsky; Z Bago-Horvath; M Weber; D Leithner; T H Helbich
Journal:  Eur Radiol       Date:  2013-12-05       Impact factor: 5.315

7.  Quadrature transmit coil for breast imaging at 7 tesla using forced current excitation for improved homogeneity.

Authors:  Mary Preston McDougall; Sergey Cheshkov; Joseph Rispoli; Craig Malloy; Ivan Dimitrov; Steven M Wright
Journal:  J Magn Reson Imaging       Date:  2014-01-24       Impact factor: 4.813

8.  An automated measurement system for characterization of RF and gradient coil parameters.

Authors:  J S Boyer; S M Wright; J R Porter
Journal:  J Magn Reson Imaging       Date:  1998 May-Jun       Impact factor: 4.813

9.  MR imaging findings in the contralateral breast of women with recently diagnosed breast cancer.

Authors:  Laura Liberman; Elizabeth A Morris; Cathleen M Kim; Jennifer B Kaplan; Andrea F Abramson; Jennifer H Menell; Kimberly J Van Zee; D David Dershaw
Journal:  AJR Am J Roentgenol       Date:  2003-02       Impact factor: 3.959

10.  A double-quadrature radiofrequency coil design for proton-decoupled carbon-13 magnetic resonance spectroscopy in humans at 7T.

Authors:  Eulalia Serés Roig; Arthur W Magill; Guillaume Donati; Martin Meyerspeer; Lijing Xin; Ozlem Ipek; Rolf Gruetter
Journal:  Magn Reson Med       Date:  2014-03-03       Impact factor: 4.668

View more
  6 in total

1.  Toward 7T breast MRI clinical study: safety assessment using simulation of heterogeneous breast models in RF exposure.

Authors:  Xin Li; Joseph V Rispoli
Journal:  Magn Reson Med       Date:  2018-09-14       Impact factor: 4.668

2.  Experimental and numerical analysis of B1(+) field and SAR with a new transmit array design for 7T breast MRI.

Authors:  Junghwan Kim; Narayan Krishnamurthy; Tales Santini; Yujuan Zhao; Tiejun Zhao; Kyongtae Ty Bae; Tamer S Ibrahim
Journal:  J Magn Reson       Date:  2016-04-23       Impact factor: 2.229

3.  A 32-channel receive array coil for bilateral breast imaging and spectroscopy at 7T.

Authors:  Romina Del Bosque; Jiaming Cui; Stephen Ogier; Sergey Cheshkov; Ivan E Dimitrov; Craig Malloy; Steven M Wright; Mary McDougall
Journal:  Magn Reson Med       Date:  2020-08-09       Impact factor: 4.668

4.  A 16-Channel 13C Array Coil for Magnetic Resonance Spectroscopy of the Breast at 7T.

Authors:  Matthew Wilcox; Stephen Ogier; Sergey Cheshkov; Ivan Dimitrov; Craig Malloy; Steven Wright; Mary McDougall
Journal:  IEEE Trans Biomed Eng       Date:  2021-05-21       Impact factor: 4.756

Review 5.  Current and Emerging Magnetic Resonance-Based Techniques for Breast Cancer.

Authors:  Apekshya Chhetri; Xin Li; Joseph V Rispoli
Journal:  Front Med (Lausanne)       Date:  2020-05-12

6.  Homogeneous B1 + for bilateral breast imaging at 7 T using a five dipole transmit array merged with a high density receive loop array.

Authors:  Erwin Krikken; Bart R Steensma; Ingmar J Voogt; Peter R Luijten; Dennis W J Klomp; Alexander J E Raaijmakers; Jannie P Wijnen
Journal:  NMR Biomed       Date:  2018-11-29       Impact factor: 4.044

  6 in total