Literature DB >> 25698620

Reliability of measures used in radiographic evaluation of the adult hip.

J A Bjarnason1, A H Pripp, O Reikeras.   

Abstract

OBJECTIVE: The reliability of radiographic measurements has been studied in pediatric hips, but less has been published on the adult hip, and none have examined the reliability of measurements for the location of the center of rotation (COR) of the hip joint. We have investigated the reliability of various radiographic variables with a focus on the COR.
MATERIALS AND METHODS: The study was carried out on a standardized format for anterior-posterior radiographs of the pelvis. The measured variables were; (A) the distance from a sagittal reference line to the COR, (B) the distance from the sagittal reference line to the proximal end of the lateral cortical line of the femur, (C) the distance from the sagittal reference line to the medial rim of the acetabulum, (D) the distance from the horizontal reference line to the roof of the acetabulum, and (E) the distance from the horizontal reference line to the COR. One observer (JAB) conducted the measurements twice separated by a time interval of 45-60 days to assess intra-observer reliability, and the first measurements of JAB were compared to those performed by another observer (OR) to assess inter-observer reliability.
RESULTS: Intraclass correlation coefficients were above 0.98 for all measurements, and the minimum and maximum values that statistically include 95% of the observer differences were all within -3 to +3 mm.
CONCLUSIONS: These measurements proved to have high reliability and agreement of both within the same observer and between two observers. They should therefore be reproducible in a clinical setting.

Entities:  

Mesh:

Year:  2015        PMID: 25698620     DOI: 10.1007/s00256-015-2101-0

Source DB:  PubMed          Journal:  Skeletal Radiol        ISSN: 0364-2348            Impact factor:   2.199


  21 in total

1.  Effect of pelvic tilt on acetabular retroversion: a study of pelves from cadavers.

Authors:  K A Siebenrock; D F Kalbermatten; R Ganz
Journal:  Clin Orthop Relat Res       Date:  2003-02       Impact factor: 4.176

2.  Reliability and agreement of measures used in radiographic evaluation of the adult hip.

Authors:  Nicholas H Mast; Franco Impellizzeri; Stephan Keller; Michael Leunig
Journal:  Clin Orthop Relat Res       Date:  2010-07-02       Impact factor: 4.176

3.  The reliability of measurements of pelvic radiographs in infants.

Authors:  F G Boniforti; G Fujii; R D Angliss; M K Benson
Journal:  J Bone Joint Surg Br       Date:  1997-07

4.  Tilt and rotation correction of acetabular version on pelvic radiographs.

Authors:  M Tannast; G Zheng; C Anderegg; K Burckhardt; F Langlotz; R Ganz; K A Siebenrock
Journal:  Clin Orthop Relat Res       Date:  2005-09       Impact factor: 4.176

5.  Radiographic analysis of femoroacetabular impingement with Hip2Norm-reliable and validated.

Authors:  Moritz Tannast; Sapan Mistry; Simon D Steppacher; Stephan Reichenbach; Frank Langlotz; Klaus A Siebenrock; Guoyan Zheng
Journal:  J Orthop Res       Date:  2008-09       Impact factor: 3.494

6.  A systematic approach to the plain radiographic evaluation of the young adult hip.

Authors:  John C Clohisy; John C Carlisle; Paul E Beaulé; Young-Jo Kim; Robert T Trousdale; Rafael J Sierra; Michael Leunig; Perry L Schoenecker; Michael B Millis
Journal:  J Bone Joint Surg Am       Date:  2008-11       Impact factor: 5.284

7.  Sample size and optimal designs for reliability studies.

Authors:  S D Walter; M Eliasziw; A Donner
Journal:  Stat Med       Date:  1998-01-15       Impact factor: 2.373

8.  Variability in the assessment of acetabular index.

Authors:  R M Kay; H G Watts; F J Dorey
Journal:  J Pediatr Orthop       Date:  1997 Mar-Apr       Impact factor: 2.324

9.  Measurement of acetabular index intraobserver and interobserver variation.

Authors:  D K Spatz; M Reiger; M Klaumann; F Miller; R P Stanton; G E Lipton
Journal:  J Pediatr Orthop       Date:  1997 Mar-Apr       Impact factor: 2.324

10.  Results of revision for mechanical failure after cemented total hip replacement, 1979 to 1982. A two to five-year follow-up.

Authors:  J J Callaghan; E A Salvati; P M Pellicci; P D Wilson; C S Ranawat
Journal:  J Bone Joint Surg Am       Date:  1985-09       Impact factor: 5.284

View more
  1 in total

1.  Changes of center of rotation and femoral offset in total hip arthroplasty.

Authors:  Jon A Bjarnason; Olav Reikeras
Journal:  Ann Transl Med       Date:  2015-12
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.