Literature DB >> 25693455

Comparison of streamlined liner of the pharynx airway (SLIPA ™) and laryngeal mask airway: a systematic review and meta-analysis.

G J Choi1, H Kang, C W Baek, Y H Jung, Y C Woo, S H Kim, J G Kim.   

Abstract

We performed a systematic review to compare the efficacy and safety of the streamlined liner of the pharynx airway and laryngeal mask airway used in adults during general anaesthesia. We included 14 studies with studies with 1273 patients in total. There was no evidence of a difference between the two devices in insertion success rate on the first attempt (13 studies, 1143 patients), insertion time (seven studies, 576 patients), ease of insertion (five studies, 466 patients), oropharyngeal leak pressure (eight studies, 771 patients) and the quality of the fibreoptic view of the larynx through the device (three studies, 281 patients). The relative risk (95% CI) of bloodstaining of the device (nine studies, 859 patients) was 2.09 (1.46-3.00) for the streamlined liner of the pharynx airway compared with the laryngeal mask airway. Other adverse events were comparable. Subgroup analysis suggested that the insertion by novice users might be faster and more successful with the streamlined liner of the pharynx airway than the laryngeal mask airway; however, this was from only two studies and 186 patients. The method of size selection of the streamlined liner of the pharynx airway device might also affect the speed of insertion: choosing according to the width of the patient's thyroid cartilage, rather than height, may produce better results.
© 2015 The Association of Anaesthetists of Great Britain and Ireland.

Entities:  

Mesh:

Year:  2015        PMID: 25693455     DOI: 10.1111/anae.13035

Source DB:  PubMed          Journal:  Anaesthesia        ISSN: 0003-2409            Impact factor:   6.955


  4 in total

1.  Comparison of the third-generation streamlined liner of the pharynx airway (SLIPA-3G) with the laryngeal mask airway supreme for laparoscopic cholecystectomy: a randomized prospective study.

Authors:  Hongna Fan; Lin Li; Lei Zhu; Zhuo Yi; Yugang Diao
Journal:  BMC Anesthesiol       Date:  2022-04-05       Impact factor: 2.217

2.  Pre-warming the Streamlined Liner of the Pharynx Airway (SLIPA) improves fitting to the laryngeal structure: a randomized, double-blind study.

Authors:  Hyun Kang; Dong Rim Kim; Yong Hun Jung; Chong Wha Baek; Yong Hee Park; Jong In Oh; Won Joong Kim; Geun Joo Choi
Journal:  BMC Anesthesiol       Date:  2015-11-20       Impact factor: 2.217

Review 3.  Scandinavian SSAI clinical practice guideline on pre-hospital airway management.

Authors:  M Rehn; P K Hyldmo; V Magnusson; J Kurola; P Kongstad; L Rognås; L K Juvet; M Sandberg
Journal:  Acta Anaesthesiol Scand       Date:  2016-06-03       Impact factor: 2.105

4.  Evaluation of performance of Streamlined Liner of the Pharynx Airway™, Laryngeal Mask Airway-ProSeal and endotracheal tube in prone position: A prospective, randomised study.

Authors:  Harihar Vishwanath Hegde; Joshiraj Bandi; Mahantesh S Mudakanagoudar; Kiran A Honnannavar
Journal:  Indian J Anaesth       Date:  2018-03
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.