Fabrication and evaluation of an improved polymer-based cochlear electrode array for atraumatic insertion.

Tae Mok Gwon1, Kyou Sik Min, Jin Ho Kim, Seung Ha Oh, Ho Sun Lee, Min-Hyun Park, Sung June Kim.   

Abstract

An atraumatic cochlear electrode array has become indispensable to high-performance cochlear implants such as electric acoustic stimulation (EAS), wherein the preservation of residual hearing is significant. For an atraumatic implantation, we propose and demonstrate a new improved design of a cochlear electrode array based on liquid crystal polymer (LCP), which can be fabricated by precise batch processes and a thermal lamination process, in contrast to conventional wire-based cochlear electrode arrays. Using a thin-film process of LCP-film-mounted silicon wafer and thermal press lamination, we devise a multi-layered structure with variable layers of LCP films to achieve a sufficient degree of basal rigidity and a flexible tip. A peripheral blind via and self-aligned silicone elastomer molding process can reduce the width of the array. Measuring the insertion and extraction forces in a human scala tympani model, we investigate five human temporal bone insertion trials and record electrically evoked auditory brainstem responses (EABR) acutely in a guinea pig model. The diameters of the finalized electrode arrays are 0.3 mm (tip) and 0.75 mm (base). The insertion force with a displacement of 8 mm from a round window and the maximum extraction force are 2.4 mN and 34.0 mN, respectively. The electrode arrays can be inserted from 360° to 630° without trauma at the basal turn. The EABR data confirm the efficacy of the array. A new design of LCP-based cochlear electrode array for atraumatic implantation is fabricated. Verification indicates that foretells the development of an atraumatic cochlear electrode array and clinical implant.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25681972     DOI: 10.1007/s10544-015-9941-1

Source DB:  PubMed          Journal:  Biomed Microdevices        ISSN: 1387-2176            Impact factor:   2.838


  4 in total

1.  Implantable electrical stimulation bioreactor with liquid crystal polymer-based electrodes for enhanced bone regeneration at mandibular large defects in rabbit.

Authors:  Chaebin Kim; Hoon Joo Yang; Tae Hyung Cho; Beom Seok Lee; Tae Mok Gwon; Soowon Shin; In Sook Kim; Sung June Kim; Soon Jung Hwang
Journal:  Med Biol Eng Comput       Date:  2019-12-18       Impact factor: 2.602

2.  Study of the Carrier-Aided Thin Film Electrode Array Design for Cochlear Insertion.

Authors:  Yuchen Xu; Chuan Luo; Fan-Gang Zeng; John C Middlebrooks; Harrison W Lin; Zheng You
Journal:  Micromachines (Basel)       Date:  2018-04-27       Impact factor: 2.891

3.  Hemispherical Microelectrode Array for Ex Vivo Retinal Neural Recording.

Authors:  Yoonhee Ha; Hyun-Ji Yoo; Soowon Shin; Sang Beom Jun
Journal:  Micromachines (Basel)       Date:  2020-05-25       Impact factor: 2.891

4.  Current Stimulation of the Midbrain Nucleus in Pigeons for Avian Flight Control.

Authors:  Jungwoo Jang; Changhoon Baek; Sunhyo Kim; Tae-Kyeong Lee; Gwang-Jin Choi; Shinyong Shim; Seunghyeon Yun; Younginha Jung; Chae-Eun Lee; Seunghyung Ko; Kangmoon Seo; Jong-Mo Seo; Moo-Ho Won; Sung J Kim; Yoon-Kyu Song
Journal:  Micromachines (Basel)       Date:  2021-06-30       Impact factor: 2.891

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.