Literature DB >> 25678247

Abutment height influences the effect of platform switching on peri-implant marginal bone loss.

Pablo Galindo-Moreno1, Ana León-Cano1, Alberto Monje2, Inmaculada Ortega-Oller1, Francisco O'Valle3, Andrés Catena4.   

Abstract

PURPOSE: The purpose was to radiographically analyze and compare the marginal bone loss (MBL) between implants with different mismatching distance and to study the influence of the prosthetic abutment height on the MBL in association with the related mismatching distances.
MATERIAL AND METHODS: This retrospective study included 108 patients in whom 228 implants were placed, 180 with diameter of 4.5 mm and 48 with diameter of 5 mm. All patients received OsseoSpeed™ implants with internal tapered conical connection (Denstply Implants). Different mismatching distances were obtained, given that all implants were loaded with the same uni-abutment type (Lilac; Denstply Implants). Data were gathered on age, gender, bone substratum, smoking habits, previous history of periodontitis, and prosthetic features. MBL was analyzed radiographically at 6 and 18 months post-loading.
RESULTS: Mixed linear analysis of mesial and distal MBL values yielded significant effects of abutment, implant diameter, follow-up period, bone substratum, smoking, and abutment × time interaction. MBL was greater at 18 vs. 6 months, for short vs. long abutments, for grafted vs. pristine bone, for a heavier smoking habit, and for implants with a diameter of 5.0 vs. 4.5 mm.
CONCLUSION: Greater mismatching does not minimize the MBL; abutment height, smoking habit, and bone substratum may play a role in the MBL over the short- and medium term.
© 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  alveolar bone loss; dental implant and dental implant-abutment connection; peri-implantitis

Mesh:

Year:  2015        PMID: 25678247     DOI: 10.1111/clr.12554

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  7 in total

1.  One Abutment One Time: A Multicenter, Prospective, Controlled, Randomized Study.

Authors:  José Vicente Ríos-Santos; Gregorio Tello-González; Pedro Lázaro-Calvo; Francisco Javier Gil Mur; Blanca Ríos-Carrasco; Ana Fernández-Palacín; Mariano Herrero-Climent
Journal:  Int J Environ Res Public Health       Date:  2020-12-17       Impact factor: 3.390

2.  The Association of the One-Abutment at One-Time Concept with Marginal Bone Loss around the SLA and Platform Switch and Conical Abutment Implants.

Authors:  Nasreen Hamudi; Eitan Barnea; Evgeny Weinberg; Amir Laviv; Eitan Mijiritsky; Shlomo Matalon; Liat Chaushu; Roni Kolerman
Journal:  J Clin Med       Date:  2021-12-24       Impact factor: 4.241

3.  Restorative angle of zirconia restorations cemented on non-original titanium bases influences the initial marginal bone loss: 5-year results of a prospective cohort study.

Authors:  Franz J Strauss; Marina Siegenthaler; Christoph H F Hämmerle; Irena Sailer; Ronald E Jung; Daniel S Thoma
Journal:  Clin Oral Implants Res       Date:  2022-05-29       Impact factor: 5.021

4.  Immediate Loading of Implant-Supported Single Crowns after Conventional and Ultrasonic Implant Site Preparation: A Multicenter Randomized Controlled Clinical Trial.

Authors:  Claudio Stacchi; Teresa Lombardi; Domenico Baldi; Calogero Bugea; Antonio Rapani; Giuseppe Perinetti; Angelo Itri; David Carpita; Guido Audenino; Giuseppe Bianco; Simone Verardi; Stefano Carossa; Gianmario Schierano
Journal:  Biomed Res Int       Date:  2018-08-14       Impact factor: 3.411

5.  Patient-centered rehabilitation of single, partial, and complete edentulism with cemented- or screw-retained fixed dental prosthesis: The First Osstem Advanced Dental Implant Research and Education Center Consensus Conference 2017.

Authors:  Marco Tallarico; Marco Caneva; Nicola Baldini; Fulvio Gatti; Marco Duvina; Mauro Billi; Gaetano Iannello; Giacomo Piacentini; Silvio Mario Meloni; Marco Cicciù
Journal:  Eur J Dent       Date:  2018 Oct-Dec

6.  Influence of the implant-abutment connection on the ratio between height and thickness of tissues at the buccal zenith: a randomized controlled trial on 188 implants placed in 104 patients.

Authors:  Davide Farronato; Pietro Mario Pasini; Mattia Manfredini; Cristian Scognamiglio; Andrea Alain Orsina; Marco Farronato
Journal:  BMC Oral Health       Date:  2020-02-17       Impact factor: 2.757

7.  Analysis of Peri-Implant Bone Loss with a Convergent Transmucosal Morphology: Retrospective Clinical Study.

Authors:  María Costa Castillo; Martín Laguna Martos; Rocío Marco Pitarch; Marina García Selva; Silvia Del Cid Rodríguez; Carla Fons-Badal; Rubén Agustín Panadero
Journal:  Int J Environ Res Public Health       Date:  2022-03-15       Impact factor: 3.390

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.