Variable torque prescription: state of art.

Mariano Lacarbonara1, Ettore Accivile1, Maria R Abed2, Dinoi M Teresa2, Annalisa Monaco1, Giuseppe Marzo1, Mario Capogreco1.   

Abstract

The variable prescription is widely described under the clinical aspect: the clinics is the result of the evolution of the state-of-the-art, aspect that is less considered in the daily literature. The state-of-the-art is the key to understand not only how we reach where we are but also to learn how to manage propely the torque, focusing on the technical and biomechanical purpos-es that led to the change of the torque values over time. The aim of this study is to update the clinicians on the aspects that affect the torque under the biomechanical sight, helping them to understand how to managing it, following the "timeline changes" in the different techniques so that the Variable Prescription Orthodontic (VPO) would be a suitable tool in every clinical case.

Entities:  

Keywords:  Active-passive; low friction; self-ligating brackets (SLB); torque expression; variable prescription orthodontic (VPO).

Year:  2015        PMID: 25674173      PMCID: PMC4319203          DOI: 10.2174/1874210601509010060

Source DB:  PubMed          Journal:  Open Dent J        ISSN: 1874-2106


INTRODUCTION

In orthodontics the meaning of the torque is different clinically and biomechanically. Clinically, the “torque” is the third key of the occlusion, described by Andrews as the inclination of the dental crown antero-posteriorly in the frontal teeth and traversal in the backward teeth. The clinical evaluation of torque is made by tracing a line perpendicular to the dental margin and passing through the Facial Axis Crown (FAC) of the tooth: the torque is considered “positive” when the crown is in a forward position to the line and the root is in backward position: in the opposite situation there is the “negative” torque [1]. Biomechanically, the torque is represented by the torsion of a rectangular archwire in the bracket slot [2]. The adequate torque is related to good aesthetics, a correct anterior guidance is associated with the overjet and overbite correction: conversely a limitation of torque control in the anterior area causes a shortening of the dental arch, while a limitation of torque in the posterior area can determine a narrower smile and possible interferences [3-5]. Considering the importance of the torque management, the knowledge of the factors affecting the torque is mandatory: the torque depends on the dental morphology, the arch wire material, the bracket position and ligature [6-2]. The bracket/archwire interaction is one of the most discussed items within torque management and control, especially in this historical moment, where the self-ligating brackets are catching on the orthodontic view: the self-ligating brackets present advantages such as achieving a good occlusion associated to a good aesthetics, less treatment time, less time at the chair side with less appointment need and greater patient satisfaction [13, 14]. The advantages of self-ligating brackets have a high support by clinicians and a lower support by the evidence, especially on the toque management, where the maintenance/loss of torque in the bracket is debated [15]. The aim of this review is to describe the current state of the art, following the timeline of the different techniques, from the pre-adjusted system to the VPO: this update allows the clinician to understand the mechanisms that underlying the torque control, giving guidelines for each clinical situation.

MATERIALS AND METHODS

The literature has been reviewed to describe the historical development of the appliances, from the origin of the pre-adjusted appliance until the Variable Prescription Orthodontics, especially regarding to the change of the bracket-wire interaction and the change of the biomechanical principles that underlying various techniques and justify different torque management.

The Origin of VPO

The pre-adjusted appliance started with Lawrence Andrews, author that re-evaluated the previous orthodontic experiences that began his research studying the occlusion and identifying six keys of optimal occlusion: the third key is represented by the torque and the technique was characterized by a bracket containing the angulation, inclination and in-out of each tooth, interacting with a straight-wire [1,16-19]. The aim of Andrews was to achieve the six keys of the occlusion, using different bracket prescriptions for each clinical situation, dividing the extractions cases from non-extraction cases [20] Table . Subsequently, Roth criticized Andrews furnishing of brackets: Roth sustained that a large inventory was difficult to manage, so he suggested a new prescription that he called Straight Wire, with a unique torque value of the upper canines (11°), aiming to use the same brackets for extractions and non-extraction cases [21]. The idea of Roth was to develop a new treatment planning aiming to achieve a facial and dental aesthetics associated to a functional occlusion, a healthy periodontium and healthy TMJ Table . The third-generation of Straight wire devices is represented by the MBT technique. McLaughling, Bennet and Trevisi modified the prescriptions of Roth and Andrews: this modification is due to the introduction of a sliding mechanics, so that light forces could be used to close the extraction spaces. The versatility of torque is represented by three different prescriptions for the upper and lower canines, choosing the correct value on the malocclusion characteristics and on the treatment goals [22, 23] Table . The MBT technique added to Andrews’s and Roth’s treatment goals also that the condyle has to be seated in a centric relation and the musculature has to be in a relaxed position during the occlusion [22, 23].

The Concept of Variable Torque Prescription

The evolution of orthodontics with self-ligating brackets pave the way for orthodontist not only to a new biomechanics but also to a new concept of treatment planning: each malocclusion present peculiar characteristics in the inclination of posterior and anterior teeth in both arches so the information inside the bracket must be chosen considering the occlusal features before the treatment and the biomechanics to achieve the final result. The different characteristics that could be found inside a malocclusion lead to develop of different prescription of torque for the upper and lower six anterior teeth: the aim of this individualization is to achieve a better functional and aesthetic outcome, with less risk of orthodontic relapse. The beginning of interest on the torque values has born from the clinical evaluation of the loss of torque with passive self-ligating brackets: the correct torque value could be achieved reducing and/or adding the degrees of torque inside the prescription [24]. Nowadays, the authors that most emphasized the VPO concept are A. Sondhi and D. Damon: they suggest that the correct torque value has to be selected considering the patient malocclusion and periodontal characteristics, the inter- and intra-arch variables and the class correction biomechanics [25, 26]. All the possible clinical combinations lead to high-, standard and low- torque prescriptions for upper and lower anterior teeth: the high torque values are taken by Hilgers, the standard torque correspond to the MBT values, whereas the low torque values are the Roth values (Fig. ).

DISCUSSION

Traditionally, the torque is achieved when the rectangular wire is full engaged to the slot of the bracket: the full-size wire is the last one of the archwire sequence and it must allow the sliding movement of the dentition and the torque control at the same time. For many authors the optimal bracket-archwire relationship is represented by a 0.022”x 0.028” slot and the 0.019”x 0.025” stainless steel wire [5, 11, 27]: this combination does not permit a full-engagement of the arch wire in the slot because only 10% of the wire is used. This aspect opens a discussion about the discrepancy between the information provided by the companies and the real wire-bracket interaction, especially because during alignment and levelling the discrepancies are less evident [28-31]. In this situation the orthodontist needs a more clear view about the variables concerning the torque expression and, on this topic, some keys of comprehension are fundamental: the different effectiveness in torque expression of the different alloys, the effect of bracket position and dental morphology on torque expression, the influence of bracket design on its capacity to read the torque (friction and bracket/wire interaction).

The Archwire Alloy

The archwire alloy is fundamental for the expression of the torque because it is the stiffness of the material that determines the complete reading of the bracket information: in fact, at the same thickness values, NiTi and the TMA alloys presented a lower stiffness, so they present a lower torque expression then the Stainless steel alloy [32] (Fig. ). The aspect that is considered critical in the torque achievement with the TMA and NiTi alloy is represented by the twist angle produced by the wire in the bracket: Archambault referred that, if the angle is lower then 12° there are no differences between the wires [33]. With this assumption, using the variable prescription will provide the correct torque because the loss of torque determined by the wire could be compensated by the information inside the bracket.

The Bracket Positioning

The force that determines the torque is correctly expressed when the force is applied in the center of the clinical crown: a different positioning, as demonstrated by Meyer and Mietheke, could determine a variation of the torsion angle by 10° to 15° [6, 31] Fig. (). The bracket positioning could also be affected by the dental morphology: a divergency between the longitudinal axis of the crown and of the root could change the effect of the same bracket [34]. If on the one hand the orthodontists are used to correct the bracket’s position by correctly debonding and rebonding the bracket, on the other hand, the debonding procedures present their unfavorable effects [35]: the change of bracket position on the vertical aspect, if the verticality is properly controlled, could be a good clinical option to reduce/add torque, especially when the VPO is applied.

The Brackets Design

The brackets are built in different materials and present more then one design: Morina compaired the ability of conventional brackets versus self-ligating brackets to generate the moment angle able to produce the torque. The ceramic brackets showed the best function in torque maintenance, followed by conventional metal brackets, then self-ligating active brackets and self-ligating passive brackets: in agreement with other researches, this study also revealed that the best range of moment of forces that generates the torque is between the 5 and 20 Nmm [36-38]. The authors detected that, with active self-ligating brackets the angle formed between the bracket and the wire had to range between 15° and 31° to achieve the optimal torque, with passive self-ligating brackets the same values of torque were achieved with angles between 22.5° and 34.5°: these results agree with previous literature such as Gymrek’s and Harzer’s studies [38, 39] Fig. (). The conclusion on most of these studies are clinically useful up to a certain point because most of them are in vitro studies, so the in vivo studies show lower levels of moments: the most difficult part under a clinical point of view is represented by the engagement of the archwire when the malocclusion is severe, and torque is determined not only by the momentum angle, but is also influenced by the friction due to dental malposition.

CONCLUSION

In orthodontics the torque control is fundamental under a clinical point of view. Nowadays, many studies underline the importance of considering the factors that affect the torque expression and management, such as the patient’s malocclusion and general characteristics, the bracket’s design, the wire’s components and sequence, the bracket positioning and the treatment biomechanics. The VPO is a good tool for the orthodontist to manage the torque since The beginning of treatment, because many of the factors affecting are considered. Looking forward, new comparative studies on the effectiveness of the treatment planning using the VPO versus the conventional treatment planning are required.
Table 1.

Prescription in Andrews technique.

Upper ArchInclinationAngulationCounter RotationLower ArchInclinationAngulationCounter Rotation
Central+7°+4°0Central-6°+1.5°0
Lateral+4°+8°0Lateral-6°+1.5°0
Cuspid+8°0Cuspid-11°0
Cuspid-7°+10°2MCuspid-11°2M
1st Bicuspid-7°+201st Bicuspid-17°0
1st Bicuspid-7°+4°2M1st Bicuspid-17°2M
2nd Bicuspid-7°+202nd Bicuspid-22°0
2nd Bicuspid-7°2D2nd Bicuspid-22°02D
Table 2.

Prescription in Roth technique.

Upper ArchInclinationAngulationOff-setLower ArchInclinationAngulationOff-set
Central12°Central
LateralLateral
Cuspid011°Cuspid-11°
1st Bicuspid-7°1st Bicuspid-17°
2nd Bicuspid-7°2nd Bicuspid-22°
Table 3.

Prescription in MBT technique.

Upper ArchInclinationAngulationLower ArchInclinationAngulation
Central+17°+4°Central-6°0
Lateral+10°+8°Lateral-6°0
Cuspid7°/-7°+8°Cuspid6°/-6°
Cuspid0+8°Cuspid0
1st Bicuspid-7°01st Bicuspid-12°
2nd Bicuspid-7°02nd Bicuspid-17°
  24 in total

1.  The influence of maxillary incisor inclination on arch length.

Authors:  E A O'Higgins; R H Kirschen; R T Lee
Journal:  Br J Orthod       Date:  1999-06

2.  Torque transmission between square wire and bracket as a function of measurement, form and hardness parameters.

Authors:  H Fischer-Brandies; W Orthuber; M Es-Souni; S Meyer
Journal:  J Orofac Orthop       Date:  2000       Impact factor: 1.938

3.  An evaluation of slot size in orthodontic brackets--are standards as expected?

Authors:  A C Cash; S A Good; R V Curtis; F McDonald
Journal:  Angle Orthod       Date:  2004-08       Impact factor: 2.079

Review 4.  Variations in bracket placement in the preadjusted orthodontic appliance.

Authors:  N Balut; L Klapper; J Sandrik; D Bowman
Journal:  Am J Orthod Dentofacial Orthop       Date:  1992-07       Impact factor: 2.650

5.  On mechanical properties of square and rectangular stainless steel wires tested in torsion.

Authors:  T R Meling; J Odegaard; E O Meling
Journal:  Am J Orthod Dentofacial Orthop       Date:  1997-03       Impact factor: 2.650

6.  Dwight Damon, DDS, MSD.

Authors:  Dwight Damon; Robert G Keim
Journal:  J Clin Orthod       Date:  2012-11

7.  The straight-wire appliance 17 years later.

Authors:  R H Roth
Journal:  J Clin Orthod       Date:  1987-09

8.  Variability of effective root torque as a function of edge bevel on orthodontic arch wires.

Authors:  J Sebanc; W A Brantley; J J Pincsak; J P Conover
Journal:  Am J Orthod       Date:  1984-07

9.  On the use of nomograms to determine the elastic property ratios of orthodontic arch wires.

Authors:  R P Kusy
Journal:  Am J Orthod       Date:  1983-05

Review 10.  Effect of orthodontic debonding and adhesive removal on the enamel - current knowledge and future perspectives - a systematic review.

Authors:  Joanna Janiszewska-Olszowska; Tomasz Szatkiewicz; Robert Tomkowski; Katarzyna Tandecka; Katarzyna Grocholewicz
Journal:  Med Sci Monit       Date:  2014-10-20
View more
  1 in total

1.  Buccolingual Inclination Control of Upper Central Incisors of Aligners: A Comparison with Conventional and Self-Ligating Brackets.

Authors:  Maria Francesca Sfondrini; Paola Gandini; Tommaso Castroflorio; Francesco Garino; Luca Mergati; Krizia D'Anca; Federico Trovati; Andrea Scribante
Journal:  Biomed Res Int       Date:  2018-11-29       Impact factor: 3.411

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.